{"title":"假体间骨折后使用模块化巨型内假体进行股骨骺端次全置换。病例报告。","authors":"Mohamed Ghanem, Christina Pempe, Andreas Roth","doi":"10.3205/iprs000183","DOIUrl":null,"url":null,"abstract":"<p><p>Mega-endoprostheses enable wide management options in the treatment of primary and periprosthetic fracture of the lower extremities. In this study, we report on the use of custom-made subtotal diaphyseal endoprosthetic replacement in treatment of interprosthetic femoral fracture. This procedure is off-label, but in this particular case, it was the safest and most stress-stable treatment option. The implant was delivered within three weeks. The surgical procedure for subtotal replacement of the femoral diaphysis was performed without any intra- or postoperative complication. The duration for the surgical intervention was one hour and 40 minutes. The patient was then mobilized with full weight bearing. At one-year follow-up, the patient did not complain of any pain. The Harris Hip Score HHS improved from 26 to 83 at one-year follow-up, the Western Ontario and McMaster Universities Osteoarthritis Index WOMAC improved from 88 to 16. Mega-endoprostheses enable a wide range of management options in the treatment of primary, peri- and interprosthetic fractures of the lower extremities. In many cases, an individual therapeutic plan is necessary ranging up to the use of custom-made implants.</p>","PeriodicalId":43347,"journal":{"name":"GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2024-02-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10963900/pdf/","citationCount":"0","resultStr":"{\"title\":\"Subtotal diaphyseal replacement of the femur with modular mega-endoprosthesis following interprosthetic fracture. A case report.\",\"authors\":\"Mohamed Ghanem, Christina Pempe, Andreas Roth\",\"doi\":\"10.3205/iprs000183\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Mega-endoprostheses enable wide management options in the treatment of primary and periprosthetic fracture of the lower extremities. In this study, we report on the use of custom-made subtotal diaphyseal endoprosthetic replacement in treatment of interprosthetic femoral fracture. This procedure is off-label, but in this particular case, it was the safest and most stress-stable treatment option. The implant was delivered within three weeks. The surgical procedure for subtotal replacement of the femoral diaphysis was performed without any intra- or postoperative complication. The duration for the surgical intervention was one hour and 40 minutes. The patient was then mobilized with full weight bearing. At one-year follow-up, the patient did not complain of any pain. The Harris Hip Score HHS improved from 26 to 83 at one-year follow-up, the Western Ontario and McMaster Universities Osteoarthritis Index WOMAC improved from 88 to 16. Mega-endoprostheses enable a wide range of management options in the treatment of primary, peri- and interprosthetic fractures of the lower extremities. In many cases, an individual therapeutic plan is necessary ranging up to the use of custom-made implants.</p>\",\"PeriodicalId\":43347,\"journal\":{\"name\":\"GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-02-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10963900/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3205/iprs000183\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"GMS Interdisciplinary Plastic and Reconstructive Surgery DGPW","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3205/iprs000183","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
Subtotal diaphyseal replacement of the femur with modular mega-endoprosthesis following interprosthetic fracture. A case report.
Mega-endoprostheses enable wide management options in the treatment of primary and periprosthetic fracture of the lower extremities. In this study, we report on the use of custom-made subtotal diaphyseal endoprosthetic replacement in treatment of interprosthetic femoral fracture. This procedure is off-label, but in this particular case, it was the safest and most stress-stable treatment option. The implant was delivered within three weeks. The surgical procedure for subtotal replacement of the femoral diaphysis was performed without any intra- or postoperative complication. The duration for the surgical intervention was one hour and 40 minutes. The patient was then mobilized with full weight bearing. At one-year follow-up, the patient did not complain of any pain. The Harris Hip Score HHS improved from 26 to 83 at one-year follow-up, the Western Ontario and McMaster Universities Osteoarthritis Index WOMAC improved from 88 to 16. Mega-endoprostheses enable a wide range of management options in the treatment of primary, peri- and interprosthetic fractures of the lower extremities. In many cases, an individual therapeutic plan is necessary ranging up to the use of custom-made implants.