没有任何优化设备的标准高清结肠镜筛查已不再适用:是时候转向优化筛查结肠镜检查了。

IF 2.2 Q3 GASTROENTEROLOGY & HEPATOLOGY Endoscopy International Open Pub Date : 2024-03-28 eCollection Date: 2024-03-01 DOI:10.1055/a-2280-7096
David Karsenti
{"title":"没有任何优化设备的标准高清结肠镜筛查已不再适用:是时候转向优化筛查结肠镜检查了。","authors":"David Karsenti","doi":"10.1055/a-2280-7096","DOIUrl":null,"url":null,"abstract":"<p><p>Optimizing the adenoma detection rate (ADR) is a major goal in colorectal cancer (CCR) screening, as it has long been established that ADR is inversely proportional to the risk of post-colonoscopy CRC occurrence. To achieve this goal, many optimization devices have been developed, and numerous randomized controlled trials have been conducted to evaluate the benefits of these devices compared with a \"standard arm,\" which corresponds to date to high-definition white light (HD-WLI) colonoscopy. Numerous studies have confirmed the positive impact of various optimization devices, such as caps, computer-aided detection, and contrast-enhanced technologies. Moreover, the different ways in which the devices can impact ADR make them complementary. However, despite substantial and consistent data, practices remain unchanged, and HD-WLI colonoscopy, considered the \"standard,\" is still routinely performed without any optimization devices. The objective of this viewpoint is to understand the barriers to change and to show why standard screening colonoscopy without the use of any optimization devices should no longer be considered relevant in 2024.</p>","PeriodicalId":11671,"journal":{"name":"Endoscopy International Open","volume":"12 3","pages":"E463-E466"},"PeriodicalIF":2.2000,"publicationDate":"2024-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10978091/pdf/","citationCount":"0","resultStr":"{\"title\":\"Standard screening high-definition colonoscopy without any optimization device is no longer relevant: Time to move to optimized screening colonoscopy.\",\"authors\":\"David Karsenti\",\"doi\":\"10.1055/a-2280-7096\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Optimizing the adenoma detection rate (ADR) is a major goal in colorectal cancer (CCR) screening, as it has long been established that ADR is inversely proportional to the risk of post-colonoscopy CRC occurrence. To achieve this goal, many optimization devices have been developed, and numerous randomized controlled trials have been conducted to evaluate the benefits of these devices compared with a \\\"standard arm,\\\" which corresponds to date to high-definition white light (HD-WLI) colonoscopy. Numerous studies have confirmed the positive impact of various optimization devices, such as caps, computer-aided detection, and contrast-enhanced technologies. Moreover, the different ways in which the devices can impact ADR make them complementary. However, despite substantial and consistent data, practices remain unchanged, and HD-WLI colonoscopy, considered the \\\"standard,\\\" is still routinely performed without any optimization devices. The objective of this viewpoint is to understand the barriers to change and to show why standard screening colonoscopy without the use of any optimization devices should no longer be considered relevant in 2024.</p>\",\"PeriodicalId\":11671,\"journal\":{\"name\":\"Endoscopy International Open\",\"volume\":\"12 3\",\"pages\":\"E463-E466\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-03-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10978091/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Endoscopy International Open\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/a-2280-7096\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endoscopy International Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-2280-7096","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

优化腺瘤检出率(ADR)是结肠直肠癌(CCR)筛查的一个主要目标,因为人们早已证实,腺瘤检出率与结肠镜检查后发生结肠直肠癌的风险成反比。为了实现这一目标,人们开发了许多优化设备,并进行了大量随机对照试验,以评估这些设备与 "标准臂"(迄今相当于高清白光结肠镜检查)相比的优势。大量研究证实了各种优化设备的积极影响,如镜帽、计算机辅助检测和造影剂增强技术。此外,这些设备影响 ADR 的方式各不相同,因此具有互补性。然而,尽管有大量一致的数据,检查方法仍然没有改变,被认为是 "标准 "的 HD-WLI 结肠镜检查仍然在没有任何优化设备的情况下常规进行。本观点旨在了解改变的障碍,并说明为什么到 2024 年,不使用任何优化设备的标准筛查结肠镜检查将不再被认为具有相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Standard screening high-definition colonoscopy without any optimization device is no longer relevant: Time to move to optimized screening colonoscopy.

Optimizing the adenoma detection rate (ADR) is a major goal in colorectal cancer (CCR) screening, as it has long been established that ADR is inversely proportional to the risk of post-colonoscopy CRC occurrence. To achieve this goal, many optimization devices have been developed, and numerous randomized controlled trials have been conducted to evaluate the benefits of these devices compared with a "standard arm," which corresponds to date to high-definition white light (HD-WLI) colonoscopy. Numerous studies have confirmed the positive impact of various optimization devices, such as caps, computer-aided detection, and contrast-enhanced technologies. Moreover, the different ways in which the devices can impact ADR make them complementary. However, despite substantial and consistent data, practices remain unchanged, and HD-WLI colonoscopy, considered the "standard," is still routinely performed without any optimization devices. The objective of this viewpoint is to understand the barriers to change and to show why standard screening colonoscopy without the use of any optimization devices should no longer be considered relevant in 2024.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Endoscopy International Open
Endoscopy International Open GASTROENTEROLOGY & HEPATOLOGY-
自引率
3.80%
发文量
270
期刊最新文献
New cholangiopancreatoscopy-assisted diagnosis of disconnected pancreatic cuct syndrome and bridging disconnected pancreatic duct. Colonoscopy is not mammography: Challenges of applying the Duty of Candor. Complete extraction of main pancreatic duct residual and microstones using an 8-wire basket catheter. Costs and benefits of a formal quality framework for colonoscopy: Economic evaluation. Defining standards for fluoroscopy in gastrointestinal endoscopy using Delphi methodology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1