碳酸氢钠和赤藓糖醇粉气流系统清除牙种植体表面生物膜的功效

Q1 Dentistry European Journal of Dentistry Pub Date : 2024-10-01 Epub Date: 2024-03-31 DOI:10.1055/s-0044-1779424
Patr Pujarern, Arthit Klaophimai, Parinya Amornsettachai, Woraphong Panyayong, Boontharika Chuenjitkuntaworn, Dinesh Rokaya, Suphachai Suphangul
{"title":"碳酸氢钠和赤藓糖醇粉气流系统清除牙种植体表面生物膜的功效","authors":"Patr Pujarern, Arthit Klaophimai, Parinya Amornsettachai, Woraphong Panyayong, Boontharika Chuenjitkuntaworn, Dinesh Rokaya, Suphachai Suphangul","doi":"10.1055/s-0044-1779424","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong> Peri-implantitis is a common complication in implant therapy and it is one of the main contributing factors to implant failure. This can be prevented by regular maintenance with mechanical debridement. One of the recent mechanical debridement methods is air abrasion therapy using different abrasive powders. This study aimed to evaluate the two common abrasive powders of different sizes (sodium bicarbonate and erythritol) for their biofilm cleaning efficacy on dental implant surfaces.</p><p><strong>Materials and methods: </strong> In an <i>in vitro</i> setting, a total of 33 implants were divided into three groups: Group 1 (<i>n</i> =11) = no treatment; group 2 (<i>n</i> = 11) = air abrasion therapy treated group using a sodium bicarbonate powder (AIRFLOW Powder Classic Comfort, EMS Electro Medical Systems, Nyon, Switzerland); and group 3 (<i>n</i> = 11) = air abrasion therapy treated group using an erythritol powder (AIRFLOW Powder Plus, EMS Electro Medical Systems, Nyon, Switzerland). The implants in each group were subjected to biofilm formation, and group 2 and group 3 were treated with air abrasion therapy of two different powders having different sizes with the same settings. The particle sizes were sodium bicarbonate (40 µm) and erythritol (14µm). The surface characteristics of the dental implants in three groups were studied from a digital camera and under the scanning electron microscope at different magnifications. The comparison of biofilm-removal efficacy between the three groups was performed by using a one-way analysis of variance with post-hoc Dunnett's T3 test. A <i>p</i>-value less than 0.05 was chosen to indicate statistical significance.</p><p><strong>Results: </strong> There were no statistical differences (<i>p</i> > 0.05) between the two powder-treated groups for the biofilm cleaning efficacy. However, both groups showed significantly better biofilm-cleaning efficacy than the control group (<i>p</i> < 0.05).</p><p><strong>Conclusion: </strong> This suggests that both powders are effective in removing biofilm from the implant surface under ideal conditions. However, there was no clear distinction between the cleaning potential of the two powders, as both performed in a similar manner.</p>","PeriodicalId":12028,"journal":{"name":"European Journal of Dentistry","volume":" ","pages":"1022-1029"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11479729/pdf/","citationCount":"0","resultStr":"{\"title\":\"Efficacy of Biofilm Removal on the Dental Implant Surface by Sodium Bicarbonate and Erythritol Powder Airflow System.\",\"authors\":\"Patr Pujarern, Arthit Klaophimai, Parinya Amornsettachai, Woraphong Panyayong, Boontharika Chuenjitkuntaworn, Dinesh Rokaya, Suphachai Suphangul\",\"doi\":\"10.1055/s-0044-1779424\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong> Peri-implantitis is a common complication in implant therapy and it is one of the main contributing factors to implant failure. This can be prevented by regular maintenance with mechanical debridement. One of the recent mechanical debridement methods is air abrasion therapy using different abrasive powders. This study aimed to evaluate the two common abrasive powders of different sizes (sodium bicarbonate and erythritol) for their biofilm cleaning efficacy on dental implant surfaces.</p><p><strong>Materials and methods: </strong> In an <i>in vitro</i> setting, a total of 33 implants were divided into three groups: Group 1 (<i>n</i> =11) = no treatment; group 2 (<i>n</i> = 11) = air abrasion therapy treated group using a sodium bicarbonate powder (AIRFLOW Powder Classic Comfort, EMS Electro Medical Systems, Nyon, Switzerland); and group 3 (<i>n</i> = 11) = air abrasion therapy treated group using an erythritol powder (AIRFLOW Powder Plus, EMS Electro Medical Systems, Nyon, Switzerland). The implants in each group were subjected to biofilm formation, and group 2 and group 3 were treated with air abrasion therapy of two different powders having different sizes with the same settings. The particle sizes were sodium bicarbonate (40 µm) and erythritol (14µm). The surface characteristics of the dental implants in three groups were studied from a digital camera and under the scanning electron microscope at different magnifications. The comparison of biofilm-removal efficacy between the three groups was performed by using a one-way analysis of variance with post-hoc Dunnett's T3 test. A <i>p</i>-value less than 0.05 was chosen to indicate statistical significance.</p><p><strong>Results: </strong> There were no statistical differences (<i>p</i> > 0.05) between the two powder-treated groups for the biofilm cleaning efficacy. However, both groups showed significantly better biofilm-cleaning efficacy than the control group (<i>p</i> < 0.05).</p><p><strong>Conclusion: </strong> This suggests that both powders are effective in removing biofilm from the implant surface under ideal conditions. However, there was no clear distinction between the cleaning potential of the two powders, as both performed in a similar manner.</p>\",\"PeriodicalId\":12028,\"journal\":{\"name\":\"European Journal of Dentistry\",\"volume\":\" \",\"pages\":\"1022-1029\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11479729/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0044-1779424\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0044-1779424","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/31 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:种植体周围炎是种植治疗中常见的并发症,也是导致种植失败的主要因素之一。通过机械清创进行定期维护可以预防这种情况的发生。最近的一种机械清创方法是使用不同的研磨粉进行气磨治疗。本研究旨在评估两种不同大小的常见研磨粉(碳酸氢钠和赤藓糖醇)对牙科种植体表面生物膜的清洁效果:在体外环境中,33 个种植体被分为三组:第 1 组(n = 11)= 无处理组;第 2 组(n = 11)= 使用碳酸氢钠粉末(AIRFLOW Powder Classic Comfort,EMS Electro Medical Systems,Nyon,Switzerland)进行空气磨蚀处理组;第 3 组(n = 11)= 使用赤藓糖醇粉末(AIRFLOW Powder Plus,EMS Electro Medical Systems,Nyon,Switzerland)进行空气磨蚀处理组。每组的植入物都会形成生物膜,第 2 组和第 3 组使用两种不同大小的粉末,以相同的设置进行气磨治疗。颗粒大小分别为碳酸氢钠(40 微米)和赤藓糖醇(14 微米)。通过数码相机和不同放大倍数的扫描电子显微镜对三组种植体的表面特征进行了研究。三组之间生物膜去除效果的比较是通过单因素方差分析和事后邓尼特 T3 检验进行的。选择小于 0.05 的 P 值表示统计学意义:结果:两组粉末处理的生物膜清洁效果没有统计学差异(P>0.05)。然而,两组的生物膜清洁效果均明显优于对照组(p 结论:两组的生物膜清洁效果均明显优于对照组(p 结论:两组的生物膜清洁效果均明显优于对照组(p 结论):这表明在理想条件下,两种粉末都能有效清除种植体表面的生物膜。不过,两种粉末的清洁潜力并没有明显的区别,因为两者的清洁效果相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Efficacy of Biofilm Removal on the Dental Implant Surface by Sodium Bicarbonate and Erythritol Powder Airflow System.

Objective:  Peri-implantitis is a common complication in implant therapy and it is one of the main contributing factors to implant failure. This can be prevented by regular maintenance with mechanical debridement. One of the recent mechanical debridement methods is air abrasion therapy using different abrasive powders. This study aimed to evaluate the two common abrasive powders of different sizes (sodium bicarbonate and erythritol) for their biofilm cleaning efficacy on dental implant surfaces.

Materials and methods:  In an in vitro setting, a total of 33 implants were divided into three groups: Group 1 (n =11) = no treatment; group 2 (n = 11) = air abrasion therapy treated group using a sodium bicarbonate powder (AIRFLOW Powder Classic Comfort, EMS Electro Medical Systems, Nyon, Switzerland); and group 3 (n = 11) = air abrasion therapy treated group using an erythritol powder (AIRFLOW Powder Plus, EMS Electro Medical Systems, Nyon, Switzerland). The implants in each group were subjected to biofilm formation, and group 2 and group 3 were treated with air abrasion therapy of two different powders having different sizes with the same settings. The particle sizes were sodium bicarbonate (40 µm) and erythritol (14µm). The surface characteristics of the dental implants in three groups were studied from a digital camera and under the scanning electron microscope at different magnifications. The comparison of biofilm-removal efficacy between the three groups was performed by using a one-way analysis of variance with post-hoc Dunnett's T3 test. A p-value less than 0.05 was chosen to indicate statistical significance.

Results:  There were no statistical differences (p > 0.05) between the two powder-treated groups for the biofilm cleaning efficacy. However, both groups showed significantly better biofilm-cleaning efficacy than the control group (p < 0.05).

Conclusion:  This suggests that both powders are effective in removing biofilm from the implant surface under ideal conditions. However, there was no clear distinction between the cleaning potential of the two powders, as both performed in a similar manner.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
European Journal of Dentistry
European Journal of Dentistry Dentistry-Dentistry (all)
CiteScore
5.10
自引率
0.00%
发文量
161
期刊介绍: The European Journal of Dentistry is the official journal of the Dental Investigations Society, based in Turkey. It is a double-blinded peer-reviewed, Open Access, multi-disciplinary international journal addressing various aspects of dentistry. The journal''s board consists of eminent investigators in dentistry from across the globe and presents an ideal international composition. The journal encourages its authors to submit original investigations, reviews, and reports addressing various divisions of dentistry including oral pathology, prosthodontics, endodontics, orthodontics etc. It is available both online and in print.
期刊最新文献
Oral Cancer's New Enemy: Goniothalamus umbrosus Targets Oral Squamous Cell Carcinoma and Spare Human Gingival Fibroblast Cells. Moringa oleifera L. Nanosuspension Extract Administration Affects Heat Shock Protein-10 and -70 under Orthodontics Mechanical Force In Vivo. A Systematic Review and Meta-Analysis of the Prevalence of Dental Caries in the Permanent Teeth of Arab Children. Accuracy, Reproducibility, and Gaps in Different Angulations of 3D-Printed versus Milled Hybrid Ceramic Crown. Assessment of Craniofacial Growth Pattern Relative to Respiratory Mandibular Movement and Sleep Characteristics: A Pilot Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1