{"title":"用于高强度机载超声波测量的基于光纤的声强传声器","authors":"Takayuki Hoshi, Yoshiki O-oka","doi":"10.35848/1347-4065/ad38c8","DOIUrl":null,"url":null,"abstract":"\n The increasing use of airborne ultrasonic waves in daily life, driven by advances in parametric and phased arrays, has led to innovative applications like highly directional speakers, non-contact tactile feedback, 3D acoustic levitation, and medical therapies. These advancements necessitate accurate measurement of high-intensity ultrasonic waves, exceeding the capability of traditional microphones limited to around 160 dB , and highlight the growing importance of measuring the sound field not merely as scalar (sound pressure) but as vector (acoustic intensity) to accommodate future technological developments. This paper introduces an acoustic intensity microphone using optical fibers as probes to overcome these limitations. The proposed method replaces the two ordinary microphones used in the traditional acoustic intensity measurement method with thin optical fibers, minimizing sound field disturbance. Experimental validation and the structure of a practical acoustic intensity microphone are discussed, building upon foundational work presented at USE2023 with added verification and insights.","PeriodicalId":505044,"journal":{"name":"Japanese Journal of Applied Physics","volume":"64 10","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optical fiber-based acoustic intensity microphone for high-intensity airborne ultrasound measurement\",\"authors\":\"Takayuki Hoshi, Yoshiki O-oka\",\"doi\":\"10.35848/1347-4065/ad38c8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n The increasing use of airborne ultrasonic waves in daily life, driven by advances in parametric and phased arrays, has led to innovative applications like highly directional speakers, non-contact tactile feedback, 3D acoustic levitation, and medical therapies. These advancements necessitate accurate measurement of high-intensity ultrasonic waves, exceeding the capability of traditional microphones limited to around 160 dB , and highlight the growing importance of measuring the sound field not merely as scalar (sound pressure) but as vector (acoustic intensity) to accommodate future technological developments. This paper introduces an acoustic intensity microphone using optical fibers as probes to overcome these limitations. The proposed method replaces the two ordinary microphones used in the traditional acoustic intensity measurement method with thin optical fibers, minimizing sound field disturbance. Experimental validation and the structure of a practical acoustic intensity microphone are discussed, building upon foundational work presented at USE2023 with added verification and insights.\",\"PeriodicalId\":505044,\"journal\":{\"name\":\"Japanese Journal of Applied Physics\",\"volume\":\"64 10\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Japanese Journal of Applied Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35848/1347-4065/ad38c8\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese Journal of Applied Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35848/1347-4065/ad38c8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
在参数阵列和相控阵列技术进步的推动下,空气传播超声波在日常生活中的应用日益广泛,并带来了各种创新应用,如高指向性扬声器、非接触式触觉反馈、三维声学悬浮和医疗。这些进步要求对高强度超声波进行精确测量,而传统传声器的测量能力仅限于 160 dB 左右,这就凸显了测量声场的重要性,不仅要测量标量(声压),还要测量矢量(声强),以适应未来的技术发展。本文介绍了一种使用光纤作为探头的声强传声器,以克服这些限制。所提出的方法用细光纤取代了传统声强测量方法中使用的两个普通传声器,最大限度地减少了声场干扰。实验验证和实用声强传声器的结构将在 USE2023 上介绍的基础工作的基础上进行讨论,并增加验证和见解。
Optical fiber-based acoustic intensity microphone for high-intensity airborne ultrasound measurement
The increasing use of airborne ultrasonic waves in daily life, driven by advances in parametric and phased arrays, has led to innovative applications like highly directional speakers, non-contact tactile feedback, 3D acoustic levitation, and medical therapies. These advancements necessitate accurate measurement of high-intensity ultrasonic waves, exceeding the capability of traditional microphones limited to around 160 dB , and highlight the growing importance of measuring the sound field not merely as scalar (sound pressure) but as vector (acoustic intensity) to accommodate future technological developments. This paper introduces an acoustic intensity microphone using optical fibers as probes to overcome these limitations. The proposed method replaces the two ordinary microphones used in the traditional acoustic intensity measurement method with thin optical fibers, minimizing sound field disturbance. Experimental validation and the structure of a practical acoustic intensity microphone are discussed, building upon foundational work presented at USE2023 with added verification and insights.