用于高强度机载超声波测量的基于光纤的声强传声器

Takayuki Hoshi, Yoshiki O-oka
{"title":"用于高强度机载超声波测量的基于光纤的声强传声器","authors":"Takayuki Hoshi, Yoshiki O-oka","doi":"10.35848/1347-4065/ad38c8","DOIUrl":null,"url":null,"abstract":"\n The increasing use of airborne ultrasonic waves in daily life, driven by advances in parametric and phased arrays, has led to innovative applications like highly directional speakers, non-contact tactile feedback, 3D acoustic levitation, and medical therapies. These advancements necessitate accurate measurement of high-intensity ultrasonic waves, exceeding the capability of traditional microphones limited to around 160 dB , and highlight the growing importance of measuring the sound field not merely as scalar (sound pressure) but as vector (acoustic intensity) to accommodate future technological developments. This paper introduces an acoustic intensity microphone using optical fibers as probes to overcome these limitations. The proposed method replaces the two ordinary microphones used in the traditional acoustic intensity measurement method with thin optical fibers, minimizing sound field disturbance. Experimental validation and the structure of a practical acoustic intensity microphone are discussed, building upon foundational work presented at USE2023 with added verification and insights.","PeriodicalId":505044,"journal":{"name":"Japanese Journal of Applied Physics","volume":"64 10","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optical fiber-based acoustic intensity microphone for high-intensity airborne ultrasound measurement\",\"authors\":\"Takayuki Hoshi, Yoshiki O-oka\",\"doi\":\"10.35848/1347-4065/ad38c8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n The increasing use of airborne ultrasonic waves in daily life, driven by advances in parametric and phased arrays, has led to innovative applications like highly directional speakers, non-contact tactile feedback, 3D acoustic levitation, and medical therapies. These advancements necessitate accurate measurement of high-intensity ultrasonic waves, exceeding the capability of traditional microphones limited to around 160 dB , and highlight the growing importance of measuring the sound field not merely as scalar (sound pressure) but as vector (acoustic intensity) to accommodate future technological developments. This paper introduces an acoustic intensity microphone using optical fibers as probes to overcome these limitations. The proposed method replaces the two ordinary microphones used in the traditional acoustic intensity measurement method with thin optical fibers, minimizing sound field disturbance. Experimental validation and the structure of a practical acoustic intensity microphone are discussed, building upon foundational work presented at USE2023 with added verification and insights.\",\"PeriodicalId\":505044,\"journal\":{\"name\":\"Japanese Journal of Applied Physics\",\"volume\":\"64 10\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Japanese Journal of Applied Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35848/1347-4065/ad38c8\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japanese Journal of Applied Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35848/1347-4065/ad38c8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在参数阵列和相控阵列技术进步的推动下,空气传播超声波在日常生活中的应用日益广泛,并带来了各种创新应用,如高指向性扬声器、非接触式触觉反馈、三维声学悬浮和医疗。这些进步要求对高强度超声波进行精确测量,而传统传声器的测量能力仅限于 160 dB 左右,这就凸显了测量声场的重要性,不仅要测量标量(声压),还要测量矢量(声强),以适应未来的技术发展。本文介绍了一种使用光纤作为探头的声强传声器,以克服这些限制。所提出的方法用细光纤取代了传统声强测量方法中使用的两个普通传声器,最大限度地减少了声场干扰。实验验证和实用声强传声器的结构将在 USE2023 上介绍的基础工作的基础上进行讨论,并增加验证和见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optical fiber-based acoustic intensity microphone for high-intensity airborne ultrasound measurement
The increasing use of airborne ultrasonic waves in daily life, driven by advances in parametric and phased arrays, has led to innovative applications like highly directional speakers, non-contact tactile feedback, 3D acoustic levitation, and medical therapies. These advancements necessitate accurate measurement of high-intensity ultrasonic waves, exceeding the capability of traditional microphones limited to around 160 dB , and highlight the growing importance of measuring the sound field not merely as scalar (sound pressure) but as vector (acoustic intensity) to accommodate future technological developments. This paper introduces an acoustic intensity microphone using optical fibers as probes to overcome these limitations. The proposed method replaces the two ordinary microphones used in the traditional acoustic intensity measurement method with thin optical fibers, minimizing sound field disturbance. Experimental validation and the structure of a practical acoustic intensity microphone are discussed, building upon foundational work presented at USE2023 with added verification and insights.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Scintillator application of CsPbBr3 quantum dots-embedded SiO2 glasses Influence of bias voltage on the Ar/CH2F2/O2 plasma etching of Si3N4 films Development of a Pb(Zr,Ti)O3 capacitor employing an IrOx/Ir bottom electrode for highly reliable ferroelectric random access memories Monomer diffusion tendencies in complex-shaped materials by vapor deposition polymerization High-performance negative differential resistance characteristics in homoepitaxial AlN/GaN double-barrier resonant tunneling diodes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1