{"title":"利用未知输入观测器改进永磁同步电机的无模型协同控制","authors":"Xiaodong Wang, Changyin Wei, Yong Chen, Qiang Ma","doi":"10.1177/00202940241229927","DOIUrl":null,"url":null,"abstract":"Parametric uncertainties and inverter nonlinearity exist in the permanent magnet synchronous motor (PMSM) drive system, which may lead to performance degradation or failure of model-based control. This paper presents an enhanced model-free synergetic control method for PMSMs, addressing the limitations of relying on accurate motor models in existing speed control strategies. The proposed approach aims to achieve robust control performance in the presence of parameter perturbations without the need for an accurate motor model. Firstly, a new ultra-local model of the speed loop for the PMSM is established based on a newly developed ultra-local theory. Subsequently, a model-free synergetic controller is designed using the principles of synergetic control theory. To address the issue of output chattering in the sliding mode observer used to estimate the unknown part of the ultra-local model, a synergetic observer method is proposed. Simulation results are presented and compared with those obtained using a proportional-integral (PI) controller and a conventional model-free sliding mode controller. The results demonstrate that the model-free synergetic controller exhibits robust performance and provides accurate estimation of the unknown part without output chattering.","PeriodicalId":510299,"journal":{"name":"Measurement and Control","volume":"30 11","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improved model-free synergetic control of permanent magnet synchronous motor using unknown input observer\",\"authors\":\"Xiaodong Wang, Changyin Wei, Yong Chen, Qiang Ma\",\"doi\":\"10.1177/00202940241229927\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Parametric uncertainties and inverter nonlinearity exist in the permanent magnet synchronous motor (PMSM) drive system, which may lead to performance degradation or failure of model-based control. This paper presents an enhanced model-free synergetic control method for PMSMs, addressing the limitations of relying on accurate motor models in existing speed control strategies. The proposed approach aims to achieve robust control performance in the presence of parameter perturbations without the need for an accurate motor model. Firstly, a new ultra-local model of the speed loop for the PMSM is established based on a newly developed ultra-local theory. Subsequently, a model-free synergetic controller is designed using the principles of synergetic control theory. To address the issue of output chattering in the sliding mode observer used to estimate the unknown part of the ultra-local model, a synergetic observer method is proposed. Simulation results are presented and compared with those obtained using a proportional-integral (PI) controller and a conventional model-free sliding mode controller. The results demonstrate that the model-free synergetic controller exhibits robust performance and provides accurate estimation of the unknown part without output chattering.\",\"PeriodicalId\":510299,\"journal\":{\"name\":\"Measurement and Control\",\"volume\":\"30 11\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Measurement and Control\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/00202940241229927\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement and Control","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/00202940241229927","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Improved model-free synergetic control of permanent magnet synchronous motor using unknown input observer
Parametric uncertainties and inverter nonlinearity exist in the permanent magnet synchronous motor (PMSM) drive system, which may lead to performance degradation or failure of model-based control. This paper presents an enhanced model-free synergetic control method for PMSMs, addressing the limitations of relying on accurate motor models in existing speed control strategies. The proposed approach aims to achieve robust control performance in the presence of parameter perturbations without the need for an accurate motor model. Firstly, a new ultra-local model of the speed loop for the PMSM is established based on a newly developed ultra-local theory. Subsequently, a model-free synergetic controller is designed using the principles of synergetic control theory. To address the issue of output chattering in the sliding mode observer used to estimate the unknown part of the ultra-local model, a synergetic observer method is proposed. Simulation results are presented and compared with those obtained using a proportional-integral (PI) controller and a conventional model-free sliding mode controller. The results demonstrate that the model-free synergetic controller exhibits robust performance and provides accurate estimation of the unknown part without output chattering.