使用带并联交直流转换器的感应发电机的混合供电系统的稳态分析

L. Mazurenko, O. Dzhura, M. Shykhnenko
{"title":"使用带并联交直流转换器的感应发电机的混合供电系统的稳态分析","authors":"L. Mazurenko, O. Dzhura, M. Shykhnenko","doi":"10.20998/2074-272x.2024.2.10","DOIUrl":null,"url":null,"abstract":"Hybrid power supply systems (HPSSs) are considered as a good option for electric power supply of remotely located from the grid consumers due to significant fuel savings compared to diesel sets. Quick development and improvement of HPSSs may be achieved using specialized methodologies and programs. In the paper a schematic diagram is proposed and operation principles of a 400 V / 50 Hz HPSS were developed. The system’s main component is the master generating unit of the hydropower plant using a 250 kW induction generator (IG). The voltage of the system is controlled by the controller of the AC/DC power converter. The electrical frequency of the system is controlled by the speed controller of the hydropower turbine. A wind turbine, an energy storage system and a regulated dump load are connected to the IG through the AC/DC converter. Goal. The paper aims to develop a methodology for steady state performance analysis of the hydraulic turbine driven isolated IG operating in parallel through an AC/DC power converter with additional sources and consumers of active power. Methodology. The methodology for evaluation of performance characteristics of the IG operating in the proposed system has been developed. The methodology is based on the equivalent circuit of the system, equations of active and reactive power balance in the system and the superposition method. Results. The equations of frequency, voltage and power regulators of the system are given. The performance characteristics of the IG operating in the system supplying resistive and RL load in «constant voltage – constant frequency» mode are obtained. Novelty. The developed methodology is innovative in taking into account the control algorithms of the system. The comparative analysis of the IG’s performance operating in the stand-alone generating unit and in the generating unit connected to the proposed system is performed. Practical value. The developed methodology can be used for development and performance improvement of hybrid AC power systems.","PeriodicalId":170736,"journal":{"name":"Electrical Engineering & Electromechanics","volume":"35 20","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Steady-state analysis of a hybrid power supply system using an induction generator with a shunt AC/DC converter\",\"authors\":\"L. Mazurenko, O. Dzhura, M. Shykhnenko\",\"doi\":\"10.20998/2074-272x.2024.2.10\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Hybrid power supply systems (HPSSs) are considered as a good option for electric power supply of remotely located from the grid consumers due to significant fuel savings compared to diesel sets. Quick development and improvement of HPSSs may be achieved using specialized methodologies and programs. In the paper a schematic diagram is proposed and operation principles of a 400 V / 50 Hz HPSS were developed. The system’s main component is the master generating unit of the hydropower plant using a 250 kW induction generator (IG). The voltage of the system is controlled by the controller of the AC/DC power converter. The electrical frequency of the system is controlled by the speed controller of the hydropower turbine. A wind turbine, an energy storage system and a regulated dump load are connected to the IG through the AC/DC converter. Goal. The paper aims to develop a methodology for steady state performance analysis of the hydraulic turbine driven isolated IG operating in parallel through an AC/DC power converter with additional sources and consumers of active power. Methodology. The methodology for evaluation of performance characteristics of the IG operating in the proposed system has been developed. The methodology is based on the equivalent circuit of the system, equations of active and reactive power balance in the system and the superposition method. Results. The equations of frequency, voltage and power regulators of the system are given. The performance characteristics of the IG operating in the system supplying resistive and RL load in «constant voltage – constant frequency» mode are obtained. Novelty. The developed methodology is innovative in taking into account the control algorithms of the system. The comparative analysis of the IG’s performance operating in the stand-alone generating unit and in the generating unit connected to the proposed system is performed. Practical value. The developed methodology can be used for development and performance improvement of hybrid AC power systems.\",\"PeriodicalId\":170736,\"journal\":{\"name\":\"Electrical Engineering & Electromechanics\",\"volume\":\"35 20\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electrical Engineering & Electromechanics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20998/2074-272x.2024.2.10\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Engineering & Electromechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20998/2074-272x.2024.2.10","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

与柴油发电机组相比,混合动力供电系统(HPSS)可显著节省燃料,因此被认为是为远离电网的偏远地区用户供电的良好选择。使用专门的方法和程序可以快速开发和改进 HPSS。本文提出了 400 V/50 Hz HPSS 的原理图和运行原则。系统的主要组成部分是水电站的主发电机组,使用一台 250 千瓦的感应发电机(IG)。系统的电压由交流/直流电源转换器的控制器控制。系统的电频由水电涡轮机的速度控制器控制。风力涡轮机、储能系统和调节后的甩负荷通过 AC/DC 转换器与感应发电机相连。目标本文旨在开发一种方法,用于对通过 AC/DC 电源转换器与其他有功功率源和有功功率消费者并联运行的水轮机驱动隔离式中压发电机进行稳态性能分析。方法论。已开发出评估在拟议系统中运行的 IG 性能特征的方法。该方法基于系统的等效电路、系统中有功和无功功率平衡方程以及叠加法。结果。给出了系统的频率、电压和功率调节器方程。得出了在 "恒压-恒频 "模式下系统中为电阻负载和 RL 负载供电的中压调节器的性能特征。新颖性。所开发的方法在考虑系统的控制算法方面具有创新性。对独立发电机组和与拟议系统连接的发电机组中的中压发电机性能进行了比较分析。实用价值。所开发的方法可用于混合交流电力系统的开发和性能改进。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Steady-state analysis of a hybrid power supply system using an induction generator with a shunt AC/DC converter
Hybrid power supply systems (HPSSs) are considered as a good option for electric power supply of remotely located from the grid consumers due to significant fuel savings compared to diesel sets. Quick development and improvement of HPSSs may be achieved using specialized methodologies and programs. In the paper a schematic diagram is proposed and operation principles of a 400 V / 50 Hz HPSS were developed. The system’s main component is the master generating unit of the hydropower plant using a 250 kW induction generator (IG). The voltage of the system is controlled by the controller of the AC/DC power converter. The electrical frequency of the system is controlled by the speed controller of the hydropower turbine. A wind turbine, an energy storage system and a regulated dump load are connected to the IG through the AC/DC converter. Goal. The paper aims to develop a methodology for steady state performance analysis of the hydraulic turbine driven isolated IG operating in parallel through an AC/DC power converter with additional sources and consumers of active power. Methodology. The methodology for evaluation of performance characteristics of the IG operating in the proposed system has been developed. The methodology is based on the equivalent circuit of the system, equations of active and reactive power balance in the system and the superposition method. Results. The equations of frequency, voltage and power regulators of the system are given. The performance characteristics of the IG operating in the system supplying resistive and RL load in «constant voltage – constant frequency» mode are obtained. Novelty. The developed methodology is innovative in taking into account the control algorithms of the system. The comparative analysis of the IG’s performance operating in the stand-alone generating unit and in the generating unit connected to the proposed system is performed. Practical value. The developed methodology can be used for development and performance improvement of hybrid AC power systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An adaptive controller for power quality control in high speed railway with electric locomotives with asynchronous traction motors Analytical method of determining conditions for full compensation of reactive power in the power supply system Maximum power point tracking improvement using type-2 fuzzy controller for wind system based on the double fed induction generator Calculation and experimental determination of the speed of advancement of the plasma leader channel of a pulse spark discharge in atmospheric air Smart current control of the wind energy conversion system based permanent magnet synchronous generator using predictive and hysteresis model
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1