独立于活性的酶促放大技术可提高生物传感中信号的稳定性和保真度

Yibo Zhou*, Shan Hu, Hong-Wen Liu, Xinyue Xiao, Weiju Chen, Sheng Yang, Huiqiu Shi, Zhengxuan Gu, Junbin Li, Ronghua Yang* and Zhihe Qing*, 
{"title":"独立于活性的酶促放大技术可提高生物传感中信号的稳定性和保真度","authors":"Yibo Zhou*,&nbsp;Shan Hu,&nbsp;Hong-Wen Liu,&nbsp;Xinyue Xiao,&nbsp;Weiju Chen,&nbsp;Sheng Yang,&nbsp;Huiqiu Shi,&nbsp;Zhengxuan Gu,&nbsp;Junbin Li,&nbsp;Ronghua Yang* and Zhihe Qing*,&nbsp;","doi":"10.1021/cbmi.3c00127","DOIUrl":null,"url":null,"abstract":"<p >Enzymes are an important tool used for signal amplification in biosensing. However, traditional amplification methods based on enzymes are always dependent on their catalytic activities, so their signals fluctuate with the change of microenvironment (e.g., pH and temperature). In this work, we communicate an activity-independent enzyme-powered (AIEP) amplification strategy for biosensing to improve signal stability and fidelity. To verify this hypothesis, the monitoring of oxidative stress during drug-induced liver injury was carried out. Carboxylesterase (CEs), highly expressed in hepatic tissue, was selected as the amplification tool. A CEs configuration-matching fluorophore (CMF) was designed and screened, and a nanobeacon was fabricated by loading CMF within an O<sub>2</sub><sup>•–</sup>-responsive polymeric micelle. Since the degradation of the nanobeacon was triggered by O<sub>2</sub><sup>•–</sup>, CMF was released to bind with CEs, and the fluorescence was lit by CEs-CMF configuration matching but not catalytic reaction. Results demonstrated that the oxidative stress during drug-induced liver injury could be successfully monitored, and the hepatoprotective effects of repair drugs could be evaluated by cell and in vivo imaging. This strategy is flexible for bioactive molecules by altering the responsive unit and generally accessible for pharmacological evaluation.</p>","PeriodicalId":53181,"journal":{"name":"Chemical & Biomedical Imaging","volume":"2 4","pages":"304–312"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.acs.org/doi/epdf/10.1021/cbmi.3c00127","citationCount":"0","resultStr":"{\"title\":\"Activity-Independent Enzyme-Powered Amplification for Improving Signal Stability and Fidelity in Biosensing\",\"authors\":\"Yibo Zhou*,&nbsp;Shan Hu,&nbsp;Hong-Wen Liu,&nbsp;Xinyue Xiao,&nbsp;Weiju Chen,&nbsp;Sheng Yang,&nbsp;Huiqiu Shi,&nbsp;Zhengxuan Gu,&nbsp;Junbin Li,&nbsp;Ronghua Yang* and Zhihe Qing*,&nbsp;\",\"doi\":\"10.1021/cbmi.3c00127\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Enzymes are an important tool used for signal amplification in biosensing. However, traditional amplification methods based on enzymes are always dependent on their catalytic activities, so their signals fluctuate with the change of microenvironment (e.g., pH and temperature). In this work, we communicate an activity-independent enzyme-powered (AIEP) amplification strategy for biosensing to improve signal stability and fidelity. To verify this hypothesis, the monitoring of oxidative stress during drug-induced liver injury was carried out. Carboxylesterase (CEs), highly expressed in hepatic tissue, was selected as the amplification tool. A CEs configuration-matching fluorophore (CMF) was designed and screened, and a nanobeacon was fabricated by loading CMF within an O<sub>2</sub><sup>•–</sup>-responsive polymeric micelle. Since the degradation of the nanobeacon was triggered by O<sub>2</sub><sup>•–</sup>, CMF was released to bind with CEs, and the fluorescence was lit by CEs-CMF configuration matching but not catalytic reaction. Results demonstrated that the oxidative stress during drug-induced liver injury could be successfully monitored, and the hepatoprotective effects of repair drugs could be evaluated by cell and in vivo imaging. This strategy is flexible for bioactive molecules by altering the responsive unit and generally accessible for pharmacological evaluation.</p>\",\"PeriodicalId\":53181,\"journal\":{\"name\":\"Chemical & Biomedical Imaging\",\"volume\":\"2 4\",\"pages\":\"304–312\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://pubs.acs.org/doi/epdf/10.1021/cbmi.3c00127\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chemical & Biomedical Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://pubs.acs.org/doi/10.1021/cbmi.3c00127\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemical & Biomedical Imaging","FirstCategoryId":"1085","ListUrlMain":"https://pubs.acs.org/doi/10.1021/cbmi.3c00127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

酶是生物传感中信号放大的重要工具。然而,基于酶的传统放大方法始终依赖于酶的催化活性,因此其信号会随着微环境(如 pH 值和温度)的变化而波动。在这项工作中,我们交流了一种用于生物传感的独立于酶活性的(AIEP)放大策略,以提高信号的稳定性和保真度。为了验证这一假设,我们对药物诱导的肝损伤过程中的氧化应激进行了监测。肝组织中高表达的羧基酯酶(CEs)被选为放大工具。设计并筛选了一种与CEs构型相匹配的荧光团(CMF),并将CMF载入O2响应性聚合物胶束中制成了纳米信标。由于纳米灯塔的降解是由氧气触发的,CMF被释放出来与CEs结合,荧光是由CEs-CMF构型匹配而非催化反应点亮的。结果表明,该方法可成功监测药物性肝损伤过程中的氧化应激,并通过细胞和体内成像评估修复药物的保肝作用。通过改变反应单元,这种策略对于生物活性分子来说非常灵活,而且一般可用于药理学评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Activity-Independent Enzyme-Powered Amplification for Improving Signal Stability and Fidelity in Biosensing

Enzymes are an important tool used for signal amplification in biosensing. However, traditional amplification methods based on enzymes are always dependent on their catalytic activities, so their signals fluctuate with the change of microenvironment (e.g., pH and temperature). In this work, we communicate an activity-independent enzyme-powered (AIEP) amplification strategy for biosensing to improve signal stability and fidelity. To verify this hypothesis, the monitoring of oxidative stress during drug-induced liver injury was carried out. Carboxylesterase (CEs), highly expressed in hepatic tissue, was selected as the amplification tool. A CEs configuration-matching fluorophore (CMF) was designed and screened, and a nanobeacon was fabricated by loading CMF within an O2•–-responsive polymeric micelle. Since the degradation of the nanobeacon was triggered by O2•–, CMF was released to bind with CEs, and the fluorescence was lit by CEs-CMF configuration matching but not catalytic reaction. Results demonstrated that the oxidative stress during drug-induced liver injury could be successfully monitored, and the hepatoprotective effects of repair drugs could be evaluated by cell and in vivo imaging. This strategy is flexible for bioactive molecules by altering the responsive unit and generally accessible for pharmacological evaluation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Chemical & Biomedical Imaging
Chemical & Biomedical Imaging 化学与生物成像-
CiteScore
1.00
自引率
0.00%
发文量
0
期刊介绍: Chemical & Biomedical Imaging is a peer-reviewed open access journal devoted to the publication of cutting-edge research papers on all aspects of chemical and biomedical imaging. This interdisciplinary field sits at the intersection of chemistry physics biology materials engineering and medicine. The journal aims to bring together researchers from across these disciplines to address cutting-edge challenges of fundamental research and applications.Topics of particular interest include but are not limited to:Imaging of processes and reactionsImaging of nanoscale microscale and mesoscale materialsImaging of biological interactions and interfacesSingle-molecule and cellular imagingWhole-organ and whole-body imagingMolecular imaging probes and contrast agentsBioluminescence chemiluminescence and electrochemiluminescence imagingNanophotonics and imagingChemical tools for new imaging modalitiesChemical and imaging techniques in diagnosis and therapyImaging-guided drug deliveryAI and machine learning assisted imaging
期刊最新文献
Issue Editorial Masthead Issue Publication Information Issue Publication Information Issue Editorial Masthead Laser-Treated Screen-Printed Carbon Electrodes for Electrochemiluminescence imaging
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1