扫描植入大棕蝠(Eptesicus fuscus)翅膀和腿部的 p 芯片的功效

IF 1.5 3区 生物学 Q2 ZOOLOGY Journal of Mammalogy Pub Date : 2024-04-06 DOI:10.1093/jmammal/gyae030
Shane D I Seheult, Raj Panchal, Alex V Borisenko, Patrick J Bennett, Paul A Faure
{"title":"扫描植入大棕蝠(Eptesicus fuscus)翅膀和腿部的 p 芯片的功效","authors":"Shane D I Seheult, Raj Panchal, Alex V Borisenko, Patrick J Bennett, Paul A Faure","doi":"10.1093/jmammal/gyae030","DOIUrl":null,"url":null,"abstract":"Individual marking techniques are critical for studying animals, especially in the wild. Current marking methods for bats (Order Chiroptera) have practical limitations and some can cause morbidity. We tested the p-Chip (p-Chip Corp.)—a miniaturized, laser light-activated microtransponder—as a prospective marking technique in a captive research colony of Big Brown Bats (Eptesicus fuscus). We assessed long-term readability and postimplantation effects of p-Chips injected subcutaneously above the second metacarpal (wing; n = 30) and the tibia (leg; n = 13 in both locations). Following implantation (Day 0), p-Chips were scanned with a hand-held ID reader (wand) on postimplantation days (PIDs) 1, 8, 15, 22, 32, 60, 74, 81, 88, 95, and over 1 year later (PID 464). For each trial, we recorded: (1) animal handling time; (2) scan time; (3) number of wand flashes; (4) p-Chip visibility; and (5) overall condition of the bat. Average scan times for p-Chips implanted in both the wing and leg increased over the duration of the study; however, the number of wand flashes decreased, suggesting that efficacy of p-Chip recording increased with user experience. Importantly, over 464 days both the visibility and readability of p-Chips in the wing remained high and superior to tags in the leg, establishing the second metacarpal as the preferred implantation site. Observed morbidity and mortality in captive bats with p-Chips was similar to baseline values for bats without these tags. Because scan efficiency on PID 464 was comparable with earlier days, this indicates that p-Chips implanted in the wing may be suitable as a long-term marking method. Our provisional results suggest that p-Chips are viable for extended field testing to see if they are suitable as an effective alternative to traditional methods to mark bats.","PeriodicalId":50157,"journal":{"name":"Journal of Mammalogy","volume":"37 1","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2024-04-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Scanning efficacy of p-Chips implanted in the wing and leg of the Big Brown Bat (Eptesicus fuscus)\",\"authors\":\"Shane D I Seheult, Raj Panchal, Alex V Borisenko, Patrick J Bennett, Paul A Faure\",\"doi\":\"10.1093/jmammal/gyae030\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Individual marking techniques are critical for studying animals, especially in the wild. Current marking methods for bats (Order Chiroptera) have practical limitations and some can cause morbidity. We tested the p-Chip (p-Chip Corp.)—a miniaturized, laser light-activated microtransponder—as a prospective marking technique in a captive research colony of Big Brown Bats (Eptesicus fuscus). We assessed long-term readability and postimplantation effects of p-Chips injected subcutaneously above the second metacarpal (wing; n = 30) and the tibia (leg; n = 13 in both locations). Following implantation (Day 0), p-Chips were scanned with a hand-held ID reader (wand) on postimplantation days (PIDs) 1, 8, 15, 22, 32, 60, 74, 81, 88, 95, and over 1 year later (PID 464). For each trial, we recorded: (1) animal handling time; (2) scan time; (3) number of wand flashes; (4) p-Chip visibility; and (5) overall condition of the bat. Average scan times for p-Chips implanted in both the wing and leg increased over the duration of the study; however, the number of wand flashes decreased, suggesting that efficacy of p-Chip recording increased with user experience. Importantly, over 464 days both the visibility and readability of p-Chips in the wing remained high and superior to tags in the leg, establishing the second metacarpal as the preferred implantation site. Observed morbidity and mortality in captive bats with p-Chips was similar to baseline values for bats without these tags. Because scan efficiency on PID 464 was comparable with earlier days, this indicates that p-Chips implanted in the wing may be suitable as a long-term marking method. Our provisional results suggest that p-Chips are viable for extended field testing to see if they are suitable as an effective alternative to traditional methods to mark bats.\",\"PeriodicalId\":50157,\"journal\":{\"name\":\"Journal of Mammalogy\",\"volume\":\"37 1\",\"pages\":\"\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-04-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mammalogy\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://doi.org/10.1093/jmammal/gyae030\",\"RegionNum\":3,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ZOOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mammalogy","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.1093/jmammal/gyae030","RegionNum":3,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ZOOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

个体标记技术对于研究动物,尤其是野生动物至关重要。目前对蝙蝠(Chiroptera 目)的标记方法有其实际局限性,有些可能会导致发病。我们在大棕蝠(Eptesicus fuscus)的圈养研究群落中测试了 p 芯片(p-Chip 公司)--一种小型化的激光激活微转发器--作为一种前瞻性标记技术。我们评估了在第二掌骨(翅膀;n = 30)和胫骨(腿部;n = 13)上方皮下注射 p 芯片的长期可读性和植入后的效果。植入 p 芯片后(第 0 天),在植入后第 1、8、15、22、32、60、74、81、88、95 天和一年后(第 464 天)用手持式 ID 阅读器(魔棒)扫描 p 芯片。在每次试验中,我们都会记录:(1) 动物处理时间;(2) 扫描时间;(3) 魔棒闪烁次数;(4) p 芯片可见度;(5) 蝙蝠的整体状况。在研究过程中,植入翅膀和腿部的 p 芯片的平均扫描时间都有所增加;但闪烁棒的次数却有所减少,这表明随着用户经验的增加,p 芯片记录的效率也会提高。重要的是,在 464 天内,翅膀上 p 芯片的可见度和可读性仍然很高,优于腿部的标签,从而确定了第二掌骨是首选的植入部位。佩戴 p 芯片的人工饲养蝙蝠的发病率和死亡率与未佩戴这些标签的蝙蝠的基线值相似。由于 PID 464 的扫描效率与早期相当,这表明在翅膀上植入 p 芯片可能适合作为一种长期标记方法。我们的初步结果表明,p-芯片可以进行更长时间的实地测试,以确定其是否可以有效替代传统的蝙蝠标记方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Scanning efficacy of p-Chips implanted in the wing and leg of the Big Brown Bat (Eptesicus fuscus)
Individual marking techniques are critical for studying animals, especially in the wild. Current marking methods for bats (Order Chiroptera) have practical limitations and some can cause morbidity. We tested the p-Chip (p-Chip Corp.)—a miniaturized, laser light-activated microtransponder—as a prospective marking technique in a captive research colony of Big Brown Bats (Eptesicus fuscus). We assessed long-term readability and postimplantation effects of p-Chips injected subcutaneously above the second metacarpal (wing; n = 30) and the tibia (leg; n = 13 in both locations). Following implantation (Day 0), p-Chips were scanned with a hand-held ID reader (wand) on postimplantation days (PIDs) 1, 8, 15, 22, 32, 60, 74, 81, 88, 95, and over 1 year later (PID 464). For each trial, we recorded: (1) animal handling time; (2) scan time; (3) number of wand flashes; (4) p-Chip visibility; and (5) overall condition of the bat. Average scan times for p-Chips implanted in both the wing and leg increased over the duration of the study; however, the number of wand flashes decreased, suggesting that efficacy of p-Chip recording increased with user experience. Importantly, over 464 days both the visibility and readability of p-Chips in the wing remained high and superior to tags in the leg, establishing the second metacarpal as the preferred implantation site. Observed morbidity and mortality in captive bats with p-Chips was similar to baseline values for bats without these tags. Because scan efficiency on PID 464 was comparable with earlier days, this indicates that p-Chips implanted in the wing may be suitable as a long-term marking method. Our provisional results suggest that p-Chips are viable for extended field testing to see if they are suitable as an effective alternative to traditional methods to mark bats.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Mammalogy
Journal of Mammalogy 生物-动物学
CiteScore
3.30
自引率
5.90%
发文量
106
审稿时长
4-8 weeks
期刊介绍: Papers are published on mammalian behavior, conservation, ecology, genetics, morphology, physiology, and taxonomy.
期刊最新文献
A new species of Tube-nosed Bat (Chiroptera: Vespertilionidae: Murina) from Qinghai-Tibet Plateau, China. Invasive wild boar affected feral hog skull evolution over 25 years in Brazilian Pantanal wetland Thermal constraints and gender-related differences in the activity patterns of the monomorphic rodent Clyomys laticeps Dispersal of the Golden-mantled Ground Squirrel (Callospermophilus lateralis) Cave Myotis (Myotis velifer) consume diverse prey items and provide important ecosystem services
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1