{"title":"神经肌肉障碍儿童咳嗽峰值流速与呼气峰值流速的比较","authors":"","doi":"10.1016/j.prrv.2024.04.001","DOIUrl":null,"url":null,"abstract":"<div><p><span><span>Spirometry and peak cough flow testing (PCF) are commonly used in the respiratory assessment of children with a </span>neuromuscular disorder (NMD). Testing uses two different machines, increases laboratory time, costs and resource utilisation. No studies have assessed the correlation between peak expiratory flow (PEF) obtained from spirometry and PCF in children with NMD using one device. An audit of children with a NMD managed at the Children’s Hospital at Westmead in 2022–2024 aged < 20 years who performed spirometry and PCF testing on the same device (Vyaire Body Box</span><sup>TM</sup>, Ultrasonic flow meter-based, or Vyaire Pneumotachograph<sup>TM</sup>, Pneumotach flow meter-based; Germany) was conducted to assess the correlation between PCF and PEF. Fifty-one sets of testing were identified, and 40 subjects (9F) had reproducible testing and were included. Median (range) age was 14.95 (7.20–19.00) years. Median PEF (L/min) was 4.05 (1.22–10.26) and median PCF (L/min) was 4.29 (1.69–10.82). PEF and PCF had a strong Pearson’s correlation coefficient, (R = 0.97, p = 0.03). The coefficient of determination was 0.93. If laboratory resources permit, spirometry should be the test of choice for children with NMD. On average, spirometry required multiple practices to achieve reproducibility to meet ATS/ERS standards. PCF testing can be utilised for children where performing technically acceptable spirometry is not possible.</p></div>","PeriodicalId":19658,"journal":{"name":"Paediatric Respiratory Reviews","volume":"51 ","pages":"Pages 26-31"},"PeriodicalIF":4.7000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A comparison of peak cough flow and peak expiratory flow in children with neuromuscular disorders\",\"authors\":\"\",\"doi\":\"10.1016/j.prrv.2024.04.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p><span><span>Spirometry and peak cough flow testing (PCF) are commonly used in the respiratory assessment of children with a </span>neuromuscular disorder (NMD). Testing uses two different machines, increases laboratory time, costs and resource utilisation. No studies have assessed the correlation between peak expiratory flow (PEF) obtained from spirometry and PCF in children with NMD using one device. An audit of children with a NMD managed at the Children’s Hospital at Westmead in 2022–2024 aged < 20 years who performed spirometry and PCF testing on the same device (Vyaire Body Box</span><sup>TM</sup>, Ultrasonic flow meter-based, or Vyaire Pneumotachograph<sup>TM</sup>, Pneumotach flow meter-based; Germany) was conducted to assess the correlation between PCF and PEF. Fifty-one sets of testing were identified, and 40 subjects (9F) had reproducible testing and were included. Median (range) age was 14.95 (7.20–19.00) years. Median PEF (L/min) was 4.05 (1.22–10.26) and median PCF (L/min) was 4.29 (1.69–10.82). PEF and PCF had a strong Pearson’s correlation coefficient, (R = 0.97, p = 0.03). The coefficient of determination was 0.93. If laboratory resources permit, spirometry should be the test of choice for children with NMD. On average, spirometry required multiple practices to achieve reproducibility to meet ATS/ERS standards. PCF testing can be utilised for children where performing technically acceptable spirometry is not possible.</p></div>\",\"PeriodicalId\":19658,\"journal\":{\"name\":\"Paediatric Respiratory Reviews\",\"volume\":\"51 \",\"pages\":\"Pages 26-31\"},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Paediatric Respiratory Reviews\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1526054224000265\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"PEDIATRICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Paediatric Respiratory Reviews","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1526054224000265","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"PEDIATRICS","Score":null,"Total":0}
A comparison of peak cough flow and peak expiratory flow in children with neuromuscular disorders
Spirometry and peak cough flow testing (PCF) are commonly used in the respiratory assessment of children with a neuromuscular disorder (NMD). Testing uses two different machines, increases laboratory time, costs and resource utilisation. No studies have assessed the correlation between peak expiratory flow (PEF) obtained from spirometry and PCF in children with NMD using one device. An audit of children with a NMD managed at the Children’s Hospital at Westmead in 2022–2024 aged < 20 years who performed spirometry and PCF testing on the same device (Vyaire Body BoxTM, Ultrasonic flow meter-based, or Vyaire PneumotachographTM, Pneumotach flow meter-based; Germany) was conducted to assess the correlation between PCF and PEF. Fifty-one sets of testing were identified, and 40 subjects (9F) had reproducible testing and were included. Median (range) age was 14.95 (7.20–19.00) years. Median PEF (L/min) was 4.05 (1.22–10.26) and median PCF (L/min) was 4.29 (1.69–10.82). PEF and PCF had a strong Pearson’s correlation coefficient, (R = 0.97, p = 0.03). The coefficient of determination was 0.93. If laboratory resources permit, spirometry should be the test of choice for children with NMD. On average, spirometry required multiple practices to achieve reproducibility to meet ATS/ERS standards. PCF testing can be utilised for children where performing technically acceptable spirometry is not possible.
期刊介绍:
Paediatric Respiratory Reviews offers authors the opportunity to submit their own editorials, educational reviews and short communications on topics relevant to paediatric respiratory medicine. These peer reviewed contributions will complement the commissioned reviews which will continue to form an integral part of the journal.
Subjects covered include:
• Epidemiology
• Immunology and cell biology
• Physiology
• Occupational disorders
• The role of allergens and pollutants
A particular emphasis is given to the recommendation of "best practice" for primary care physicians and paediatricians.
Paediatric Respiratory Reviews is aimed at general paediatricians but it should also be read by specialist paediatric physicians and nurses, respiratory physicians and general practitioners.
It is a journal for those who are busy and do not have time to read systematically through literature, but who need to stay up to date in the field of paediatric respiratory and sleep medicine.