{"title":"根据燃料电池负载范围分析燃料电池电动公交车 BOP 系统的功耗","authors":"Yebeen Kim, Jiwoong Kim, Kyoungdoug Min","doi":"10.1007/s12239-024-00064-0","DOIUrl":null,"url":null,"abstract":"<p>The proton exchange membrane fuel cell (PEMFC) in a fuel cell electric bus (FCEB) converts hydrogen's chemical energy into electrical energy. The fuel cell system comprises a fuel cell stack and a balance of plant (BOP) system, which efficiently controls the stack. Fuel cell and battery are sensitive to operational temperature, which directly impacts performance, lifespan, and safety. Therefore, a thermal management system (TMS) is necessary to maintain an appropriate temperature by dissipating the heat generated by the fuel cell and battery. In this study, the exponential or quadratic relationships between the power consumption of the major components of an FCEB and various factors, such as temperature and flow rate influencing the operational behavior and control of the components, were analyzed based on the results of a dynamometer vehicle test. Additionally, the vehicle's energy flow was calculated under different fuel cell load conditions. When the fuel cell operated at 56.3 kW, TMS power was 6.6 times higher than at 20 kW. At full load, under 90 kW, it increased to 17.4 times higher. The rise in fuel cell load correlated with higher heat generation, resulting in a significant increase in power consumption for both the radiator fan and coolant pump.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-04-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of Power Consumption on BOP System in a Fuel Cell Electric Bus According to the Fuel Cell Load Range\",\"authors\":\"Yebeen Kim, Jiwoong Kim, Kyoungdoug Min\",\"doi\":\"10.1007/s12239-024-00064-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The proton exchange membrane fuel cell (PEMFC) in a fuel cell electric bus (FCEB) converts hydrogen's chemical energy into electrical energy. The fuel cell system comprises a fuel cell stack and a balance of plant (BOP) system, which efficiently controls the stack. Fuel cell and battery are sensitive to operational temperature, which directly impacts performance, lifespan, and safety. Therefore, a thermal management system (TMS) is necessary to maintain an appropriate temperature by dissipating the heat generated by the fuel cell and battery. In this study, the exponential or quadratic relationships between the power consumption of the major components of an FCEB and various factors, such as temperature and flow rate influencing the operational behavior and control of the components, were analyzed based on the results of a dynamometer vehicle test. Additionally, the vehicle's energy flow was calculated under different fuel cell load conditions. When the fuel cell operated at 56.3 kW, TMS power was 6.6 times higher than at 20 kW. At full load, under 90 kW, it increased to 17.4 times higher. The rise in fuel cell load correlated with higher heat generation, resulting in a significant increase in power consumption for both the radiator fan and coolant pump.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-04-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s12239-024-00064-0\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s12239-024-00064-0","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Analysis of Power Consumption on BOP System in a Fuel Cell Electric Bus According to the Fuel Cell Load Range
The proton exchange membrane fuel cell (PEMFC) in a fuel cell electric bus (FCEB) converts hydrogen's chemical energy into electrical energy. The fuel cell system comprises a fuel cell stack and a balance of plant (BOP) system, which efficiently controls the stack. Fuel cell and battery are sensitive to operational temperature, which directly impacts performance, lifespan, and safety. Therefore, a thermal management system (TMS) is necessary to maintain an appropriate temperature by dissipating the heat generated by the fuel cell and battery. In this study, the exponential or quadratic relationships between the power consumption of the major components of an FCEB and various factors, such as temperature and flow rate influencing the operational behavior and control of the components, were analyzed based on the results of a dynamometer vehicle test. Additionally, the vehicle's energy flow was calculated under different fuel cell load conditions. When the fuel cell operated at 56.3 kW, TMS power was 6.6 times higher than at 20 kW. At full load, under 90 kW, it increased to 17.4 times higher. The rise in fuel cell load correlated with higher heat generation, resulting in a significant increase in power consumption for both the radiator fan and coolant pump.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.