乳头保留切除术后乳房重建中的乳头-乳晕复合体错位:日本一项多机构回顾性观察研究

IF 4 3区 医学 Q1 OBSTETRICS & GYNECOLOGY Breast Cancer Pub Date : 2024-04-08 DOI:10.1007/s12282-024-01578-2
Sayuri Kato, Hiroki Mori, Miho Saiga, Satoko Watanabe, Shinsuke Sasada, Ayano Sasaki, Akiko Ogiya, Mao Yamamoto, Kazutaka Narui, Junji Takano, Hirohito Seki, Naomi Nagura, Makoto Ishitobi, Tadahiko Shien
{"title":"乳头保留切除术后乳房重建中的乳头-乳晕复合体错位:日本一项多机构回顾性观察研究","authors":"Sayuri Kato, Hiroki Mori, Miho Saiga, Satoko Watanabe, Shinsuke Sasada, Ayano Sasaki, Akiko Ogiya, Mao Yamamoto, Kazutaka Narui, Junji Takano, Hirohito Seki, Naomi Nagura, Makoto Ishitobi, Tadahiko Shien","doi":"10.1007/s12282-024-01578-2","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Background</h3><p>Position of the nipple–areolar complex (NAC) is an important factor in the esthetic impression of the breast, and NAC malposition is often an issue in breast reconstruction after nipple-sparing mastectomy (NSM). The purpose of this study was to evaluate the degree of NAC malposition depending on several factors using data quantified with the Mamma Balance application (Medic Engineering K.K., Kyoto, Japan).</p><h3 data-test=\"abstract-sub-heading\">Methods</h3><p>Patients who underwent unilateral breast reconstruction after NSM at eight hospitals in Japan between 2007 and 2020 were retrospectively investigated. Using Mamma Balance, NAC malposition was quantified separately in horizontal and vertical directions using patient photographs from pre-operatively and 6–24 months post-operatively. The degree of malpositioning was then statistically compared using various factors.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>The NAC deviated more cranially and medially with implants than that with flaps. Cases with latissimus dorsi flap showed lateral malposition more often than cases with deep inferior epigastric artery perforator flap. With flaps, lateral incisions showed more lateral malposition, and peri-areolar incisions tended to show more medial NAC malposition. In cases with severe post-operative infection of the implant, the NAC tended to deviate cranially. In radiation cases, the NAC deviated cranially. No significant difference was observed according to the degree of breast ptosis or use of the pull-down operation. Only a very weak correlation was observed between a larger amount of mastectomy and more cranial NAC malposition with both flaps and implants.</p><h3 data-test=\"abstract-sub-heading\">Conclusions</h3><p>This study provides insights into the tendencies and characteristics of NAC malposition.</p>","PeriodicalId":56083,"journal":{"name":"Breast Cancer","volume":null,"pages":null},"PeriodicalIF":4.0000,"publicationDate":"2024-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Nipple–areolar complex malposition in breast reconstruction after nipple-sparing mastectomy: a multi-institutional retrospective observational study in Japan\",\"authors\":\"Sayuri Kato, Hiroki Mori, Miho Saiga, Satoko Watanabe, Shinsuke Sasada, Ayano Sasaki, Akiko Ogiya, Mao Yamamoto, Kazutaka Narui, Junji Takano, Hirohito Seki, Naomi Nagura, Makoto Ishitobi, Tadahiko Shien\",\"doi\":\"10.1007/s12282-024-01578-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3 data-test=\\\"abstract-sub-heading\\\">Background</h3><p>Position of the nipple–areolar complex (NAC) is an important factor in the esthetic impression of the breast, and NAC malposition is often an issue in breast reconstruction after nipple-sparing mastectomy (NSM). The purpose of this study was to evaluate the degree of NAC malposition depending on several factors using data quantified with the Mamma Balance application (Medic Engineering K.K., Kyoto, Japan).</p><h3 data-test=\\\"abstract-sub-heading\\\">Methods</h3><p>Patients who underwent unilateral breast reconstruction after NSM at eight hospitals in Japan between 2007 and 2020 were retrospectively investigated. Using Mamma Balance, NAC malposition was quantified separately in horizontal and vertical directions using patient photographs from pre-operatively and 6–24 months post-operatively. The degree of malpositioning was then statistically compared using various factors.</p><h3 data-test=\\\"abstract-sub-heading\\\">Results</h3><p>The NAC deviated more cranially and medially with implants than that with flaps. Cases with latissimus dorsi flap showed lateral malposition more often than cases with deep inferior epigastric artery perforator flap. With flaps, lateral incisions showed more lateral malposition, and peri-areolar incisions tended to show more medial NAC malposition. In cases with severe post-operative infection of the implant, the NAC tended to deviate cranially. In radiation cases, the NAC deviated cranially. No significant difference was observed according to the degree of breast ptosis or use of the pull-down operation. Only a very weak correlation was observed between a larger amount of mastectomy and more cranial NAC malposition with both flaps and implants.</p><h3 data-test=\\\"abstract-sub-heading\\\">Conclusions</h3><p>This study provides insights into the tendencies and characteristics of NAC malposition.</p>\",\"PeriodicalId\":56083,\"journal\":{\"name\":\"Breast Cancer\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.0000,\"publicationDate\":\"2024-04-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Breast Cancer\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s12282-024-01578-2\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OBSTETRICS & GYNECOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Breast Cancer","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s12282-024-01578-2","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景乳头乳晕复合体(NAC)的位置是影响乳房美观的一个重要因素,乳头乳晕复合体位置不正通常是乳头保留乳房切除术(NSM)后乳房重建中的一个问题。本研究的目的是利用 Mamma Balance 应用程序(Medic Engineering K.K.,日本京都)量化的数据,评估 NAC 错位程度取决于几个因素。使用 Mamma Balance,利用患者术前和术后 6-24 个月的照片,分别从水平和垂直方向对 NAC 错位进行量化。结果与皮瓣相比,植入假体的 NAC 更偏向头颅和内侧。使用背阔肌皮瓣的病例比使用上腹部深动脉穿孔皮瓣的病例更容易出现外侧错位。使用皮瓣时,外侧切口更容易出现外侧错位,而乳晕周围切口则更容易出现内侧 NAC 错位。在植入物术后严重感染的病例中,NAC倾向于向颅内偏移。在放射病例中,NAC偏向头颅。乳房下垂程度和使用下拉手术的情况没有明显差异。无论是皮瓣还是假体,乳房切除术量越大,NAC位置越偏向头颅,两者之间仅存在非常微弱的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Nipple–areolar complex malposition in breast reconstruction after nipple-sparing mastectomy: a multi-institutional retrospective observational study in Japan

Background

Position of the nipple–areolar complex (NAC) is an important factor in the esthetic impression of the breast, and NAC malposition is often an issue in breast reconstruction after nipple-sparing mastectomy (NSM). The purpose of this study was to evaluate the degree of NAC malposition depending on several factors using data quantified with the Mamma Balance application (Medic Engineering K.K., Kyoto, Japan).

Methods

Patients who underwent unilateral breast reconstruction after NSM at eight hospitals in Japan between 2007 and 2020 were retrospectively investigated. Using Mamma Balance, NAC malposition was quantified separately in horizontal and vertical directions using patient photographs from pre-operatively and 6–24 months post-operatively. The degree of malpositioning was then statistically compared using various factors.

Results

The NAC deviated more cranially and medially with implants than that with flaps. Cases with latissimus dorsi flap showed lateral malposition more often than cases with deep inferior epigastric artery perforator flap. With flaps, lateral incisions showed more lateral malposition, and peri-areolar incisions tended to show more medial NAC malposition. In cases with severe post-operative infection of the implant, the NAC tended to deviate cranially. In radiation cases, the NAC deviated cranially. No significant difference was observed according to the degree of breast ptosis or use of the pull-down operation. Only a very weak correlation was observed between a larger amount of mastectomy and more cranial NAC malposition with both flaps and implants.

Conclusions

This study provides insights into the tendencies and characteristics of NAC malposition.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Breast Cancer
Breast Cancer ONCOLOGY-OBSTETRICS & GYNECOLOGY
CiteScore
6.70
自引率
2.50%
发文量
105
审稿时长
6-12 weeks
期刊介绍: Breast Cancer, the official journal of the Japanese Breast Cancer Society, publishes articles that contribute to progress in the field, in basic or translational research and also in clinical research, seeking to develop a new focus and new perspectives for all who are concerned with breast cancer. The journal welcomes all original articles describing clinical and epidemiological studies and laboratory investigations regarding breast cancer and related diseases. The journal will consider five types of articles: editorials, review articles, original articles, case reports, and rapid communications. Although editorials and review articles will principally be solicited by the editors, they can also be submitted for peer review, as in the case of original articles. The journal provides the best of up-to-date information on breast cancer, presenting readers with high-impact, original work focusing on pivotal issues.
期刊最新文献
Comparative assessment of breast volume using a smartphone device versus MRI. Correction: Trastuzumab deruxtecan for the treatment of patients with HER2-positive breast cancer with brain and/or leptomeningeal metastases: an updated overall survival analysis using data from a multicenter retrospective study (ROSET-BM). High-risk pathogenic germline variants in blood relatives of BRCA1/2 negative probands. Comparison of locoregional recurrence risk among nipple-sparing mastectomy, skin-sparing mastectomy, and simple mastectomy in patients with ductal carcinoma in situ: a single-center study. Development of a nomogram to predict recurrence scores obtained using Oncotype DX in Japanese patients with breast cancer.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1