Shikhah Almutairi, Nawal A. Alarfaj, Adibah M. Almutairi, Maha F. El-Tohamy
{"title":"利用绿色合成的金属氧化物纳米粒子进行药品中盐酸二甲双胍的电位测定","authors":"Shikhah Almutairi, Nawal A. Alarfaj, Adibah M. Almutairi, Maha F. El-Tohamy","doi":"10.1155/2024/8354311","DOIUrl":null,"url":null,"abstract":"The advanced and highly functional properties of Al<sub>2</sub>O<sub>3</sub> and NiO nanoparticles promote the widespread use of metal oxides as remarkable electroactive materials for sensing and electrochemical applications. The proposed study describes a comparison of the sensitivity and selectivity of two modified wire membrane sensors enriched with Al<sub>2</sub>O<sub>3</sub> and NiO nanoparticles with conventional wire membranes for the quantification of the antidiabetic drug metformin hydrochloride (MTF). The results show linear relationships of the enriched Al<sub>2</sub>O<sub>3</sub> and NiO nanosensors over the concentration ranges 1.0 × 10<sup>−10</sup>–1.0 × 10<sup>−2</sup> mol L<sup>−1</sup> and 1.0 × 10<sup>−6</sup>–1.0 × 10<sup>−2</sup> M for both the modified sensors and the conventional coated wire membrane sensors. The regression equations were <svg height=\"11.9087pt\" style=\"vertical-align:-3.2728pt\" version=\"1.1\" viewbox=\"-0.0498162 -8.6359 21.614 11.9087\" width=\"21.614pt\" xmlns=\"http://www.w3.org/2000/svg\" xmlns:xlink=\"http://www.w3.org/1999/xlink\"><g transform=\"matrix(.013,0,0,-0.013,0,0)\"></path></g><g transform=\"matrix(.0091,0,0,-0.0091,7.943,3.132)\"></path></g><g transform=\"matrix(.0091,0,0,-0.0091,14.537,3.132)\"></path></g></svg> = (52.1 ± 0.5) log (MTF) + 729 for enriched nanometallic oxides, <svg height=\"11.9087pt\" style=\"vertical-align:-3.2728pt\" version=\"1.1\" viewbox=\"-0.0498162 -8.6359 21.614 11.9087\" width=\"21.614pt\" xmlns=\"http://www.w3.org/2000/svg\" xmlns:xlink=\"http://www.w3.org/1999/xlink\"><g transform=\"matrix(.013,0,0,-0.013,0,0)\"><use xlink:href=\"#g113-70\"></use></g><g transform=\"matrix(.0091,0,0,-0.0091,7.943,3.132)\"><use xlink:href=\"#g190-110\"></use></g><g transform=\"matrix(.0091,0,0,-0.0091,14.537,3.132)\"><use xlink:href=\"#g190-87\"></use></g></svg> = (57.04 ± 0.4) log (MTF) + 890.66, and <svg height=\"11.9087pt\" style=\"vertical-align:-3.2728pt\" version=\"1.1\" viewbox=\"-0.0498162 -8.6359 21.614 11.9087\" width=\"21.614pt\" xmlns=\"http://www.w3.org/2000/svg\" xmlns:xlink=\"http://www.w3.org/1999/xlink\"><g transform=\"matrix(.013,0,0,-0.013,0,0)\"><use xlink:href=\"#g113-70\"></use></g><g transform=\"matrix(.0091,0,0,-0.0091,7.943,3.132)\"><use xlink:href=\"#g190-110\"></use></g><g transform=\"matrix(.0091,0,0,-0.0091,14.537,3.132)\"><use xlink:href=\"#g190-87\"></use></g></svg> = (58.27 ± 0.7) log (MTF) + 843.27 with correlation coefficients of 0.9991, 0.9997, and 0.9998 for the aforementioned sensors, respectively. The proposed method was fully validated with respect to the recommendations of the International Union of Pure and Applied Chemistry (IUPAC). The newly functionalized sensors have been successfully used for the determination of MTF in its commercial products.","PeriodicalId":13888,"journal":{"name":"International Journal of Analytical Chemistry","volume":"121 1","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2024-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Exploiting of Green Synthesized Metal Oxide Nanoparticles in the Potentiometric Determination of Metformin Hydrochloride in Pharmaceutical Products\",\"authors\":\"Shikhah Almutairi, Nawal A. Alarfaj, Adibah M. Almutairi, Maha F. El-Tohamy\",\"doi\":\"10.1155/2024/8354311\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The advanced and highly functional properties of Al<sub>2</sub>O<sub>3</sub> and NiO nanoparticles promote the widespread use of metal oxides as remarkable electroactive materials for sensing and electrochemical applications. The proposed study describes a comparison of the sensitivity and selectivity of two modified wire membrane sensors enriched with Al<sub>2</sub>O<sub>3</sub> and NiO nanoparticles with conventional wire membranes for the quantification of the antidiabetic drug metformin hydrochloride (MTF). The results show linear relationships of the enriched Al<sub>2</sub>O<sub>3</sub> and NiO nanosensors over the concentration ranges 1.0 × 10<sup>−10</sup>–1.0 × 10<sup>−2</sup> mol L<sup>−1</sup> and 1.0 × 10<sup>−6</sup>–1.0 × 10<sup>−2</sup> M for both the modified sensors and the conventional coated wire membrane sensors. The regression equations were <svg height=\\\"11.9087pt\\\" style=\\\"vertical-align:-3.2728pt\\\" version=\\\"1.1\\\" viewbox=\\\"-0.0498162 -8.6359 21.614 11.9087\\\" width=\\\"21.614pt\\\" xmlns=\\\"http://www.w3.org/2000/svg\\\" xmlns:xlink=\\\"http://www.w3.org/1999/xlink\\\"><g transform=\\\"matrix(.013,0,0,-0.013,0,0)\\\"></path></g><g transform=\\\"matrix(.0091,0,0,-0.0091,7.943,3.132)\\\"></path></g><g transform=\\\"matrix(.0091,0,0,-0.0091,14.537,3.132)\\\"></path></g></svg> = (52.1 ± 0.5) log (MTF) + 729 for enriched nanometallic oxides, <svg height=\\\"11.9087pt\\\" style=\\\"vertical-align:-3.2728pt\\\" version=\\\"1.1\\\" viewbox=\\\"-0.0498162 -8.6359 21.614 11.9087\\\" width=\\\"21.614pt\\\" xmlns=\\\"http://www.w3.org/2000/svg\\\" xmlns:xlink=\\\"http://www.w3.org/1999/xlink\\\"><g transform=\\\"matrix(.013,0,0,-0.013,0,0)\\\"><use xlink:href=\\\"#g113-70\\\"></use></g><g transform=\\\"matrix(.0091,0,0,-0.0091,7.943,3.132)\\\"><use xlink:href=\\\"#g190-110\\\"></use></g><g transform=\\\"matrix(.0091,0,0,-0.0091,14.537,3.132)\\\"><use xlink:href=\\\"#g190-87\\\"></use></g></svg> = (57.04 ± 0.4) log (MTF) + 890.66, and <svg height=\\\"11.9087pt\\\" style=\\\"vertical-align:-3.2728pt\\\" version=\\\"1.1\\\" viewbox=\\\"-0.0498162 -8.6359 21.614 11.9087\\\" width=\\\"21.614pt\\\" xmlns=\\\"http://www.w3.org/2000/svg\\\" xmlns:xlink=\\\"http://www.w3.org/1999/xlink\\\"><g transform=\\\"matrix(.013,0,0,-0.013,0,0)\\\"><use xlink:href=\\\"#g113-70\\\"></use></g><g transform=\\\"matrix(.0091,0,0,-0.0091,7.943,3.132)\\\"><use xlink:href=\\\"#g190-110\\\"></use></g><g transform=\\\"matrix(.0091,0,0,-0.0091,14.537,3.132)\\\"><use xlink:href=\\\"#g190-87\\\"></use></g></svg> = (58.27 ± 0.7) log (MTF) + 843.27 with correlation coefficients of 0.9991, 0.9997, and 0.9998 for the aforementioned sensors, respectively. The proposed method was fully validated with respect to the recommendations of the International Union of Pure and Applied Chemistry (IUPAC). The newly functionalized sensors have been successfully used for the determination of MTF in its commercial products.\",\"PeriodicalId\":13888,\"journal\":{\"name\":\"International Journal of Analytical Chemistry\",\"volume\":\"121 1\",\"pages\":\"\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-04-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Analytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1155/2024/8354311\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1155/2024/8354311","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Exploiting of Green Synthesized Metal Oxide Nanoparticles in the Potentiometric Determination of Metformin Hydrochloride in Pharmaceutical Products
The advanced and highly functional properties of Al2O3 and NiO nanoparticles promote the widespread use of metal oxides as remarkable electroactive materials for sensing and electrochemical applications. The proposed study describes a comparison of the sensitivity and selectivity of two modified wire membrane sensors enriched with Al2O3 and NiO nanoparticles with conventional wire membranes for the quantification of the antidiabetic drug metformin hydrochloride (MTF). The results show linear relationships of the enriched Al2O3 and NiO nanosensors over the concentration ranges 1.0 × 10−10–1.0 × 10−2 mol L−1 and 1.0 × 10−6–1.0 × 10−2 M for both the modified sensors and the conventional coated wire membrane sensors. The regression equations were = (52.1 ± 0.5) log (MTF) + 729 for enriched nanometallic oxides, = (57.04 ± 0.4) log (MTF) + 890.66, and = (58.27 ± 0.7) log (MTF) + 843.27 with correlation coefficients of 0.9991, 0.9997, and 0.9998 for the aforementioned sensors, respectively. The proposed method was fully validated with respect to the recommendations of the International Union of Pure and Applied Chemistry (IUPAC). The newly functionalized sensors have been successfully used for the determination of MTF in its commercial products.
期刊介绍:
International Journal of Analytical Chemistry publishes original research articles that report new experimental results and methods, especially in relation to important analytes, difficult matrices, and topical samples. Investigations may be fundamental, or else related to specific applications; examples being biological, environmental and food testing, and analysis in chemical synthesis and materials processing.
As well as original research, the International Journal of Analytical Chemistry also publishes focused review articles that examine the state of the art, identify emerging trends, and suggest future directions for developing fields.