间歇性术中神经监测 (IONM) 对普通外科住院医师全甲状腺切除术学习曲线的影响

IF 1.2 4区 医学 Q3 SURGERY Surgical Innovation Pub Date : 2024-04-18 DOI:10.1177/15533506241248974
Alessia Fassari, Alessandra Micalizzi, Giulio Lelli, Angela Gurrado, Andrea Polistena, Angelo Iossa, Francesco De Angelis, Lorenzo Martini, Giovanni Traumuller Tamagnini, Mario Testini, Giuseppe Cavallaro
{"title":"间歇性术中神经监测 (IONM) 对普通外科住院医师全甲状腺切除术学习曲线的影响","authors":"Alessia Fassari, Alessandra Micalizzi, Giulio Lelli, Angela Gurrado, Andrea Polistena, Angelo Iossa, Francesco De Angelis, Lorenzo Martini, Giovanni Traumuller Tamagnini, Mario Testini, Giuseppe Cavallaro","doi":"10.1177/15533506241248974","DOIUrl":null,"url":null,"abstract":"IntroductionRecurrent laryngeal nerve (RNL) identification constitutes the standard in thyroidectomy. Intraoperative nerve monitoring (IONM) has been introduced as a complementary tool for RLN functionality evaluation. The aim of this study is to establish how routine use of IONM can affect the learning curve (LC) in thyroidectomy.MethodsPatients undergoing total thyroidectomy performed by surgery residents in their learning curve course in 2 academic hospitals, were divided into 2 groups: Group A, including 150 thyroidectomies performed without IONM by 3 different residents, and Group B, including 150 procedures with routine use of intermittent IONM, by other 3 different residents. LC was measured by comparing operative time (OT), its stabilization during the development of the LC, perioperative complication rate.ResultsAs previously demonstrated, the LC was achieved after 30 procedures, in both groups, with no differences due to the use of IONM. Similarly, there were no significant differences among the 2 groups, and between subgroups independently matched, for both OT and complications, even when comparing RLN palsy. Direct nerve visualization and IONM assessment rates were comparable in all groups, and no bilateral RLN palsy (transient or permanent) were reported. No case of interrupted procedure to unilateral lobectomy, due to evidence of RLN injury, was reported.ConclusionsThe study demonstrates that the use of IONM thyroid surgery, despite requiring a specific training with experienced surgeons, does not particularly affect the learning curve of residents approaching this kind of surgery, and for this reason its routine use should be encouraged even for trainees.","PeriodicalId":22095,"journal":{"name":"Surgical Innovation","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-04-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact of Intermittent Intraoperative Neuromonitoring (IONM) on the Learning Curve for Total Thyroidectomy by Residents in General Surgery\",\"authors\":\"Alessia Fassari, Alessandra Micalizzi, Giulio Lelli, Angela Gurrado, Andrea Polistena, Angelo Iossa, Francesco De Angelis, Lorenzo Martini, Giovanni Traumuller Tamagnini, Mario Testini, Giuseppe Cavallaro\",\"doi\":\"10.1177/15533506241248974\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"IntroductionRecurrent laryngeal nerve (RNL) identification constitutes the standard in thyroidectomy. Intraoperative nerve monitoring (IONM) has been introduced as a complementary tool for RLN functionality evaluation. The aim of this study is to establish how routine use of IONM can affect the learning curve (LC) in thyroidectomy.MethodsPatients undergoing total thyroidectomy performed by surgery residents in their learning curve course in 2 academic hospitals, were divided into 2 groups: Group A, including 150 thyroidectomies performed without IONM by 3 different residents, and Group B, including 150 procedures with routine use of intermittent IONM, by other 3 different residents. LC was measured by comparing operative time (OT), its stabilization during the development of the LC, perioperative complication rate.ResultsAs previously demonstrated, the LC was achieved after 30 procedures, in both groups, with no differences due to the use of IONM. Similarly, there were no significant differences among the 2 groups, and between subgroups independently matched, for both OT and complications, even when comparing RLN palsy. Direct nerve visualization and IONM assessment rates were comparable in all groups, and no bilateral RLN palsy (transient or permanent) were reported. No case of interrupted procedure to unilateral lobectomy, due to evidence of RLN injury, was reported.ConclusionsThe study demonstrates that the use of IONM thyroid surgery, despite requiring a specific training with experienced surgeons, does not particularly affect the learning curve of residents approaching this kind of surgery, and for this reason its routine use should be encouraged even for trainees.\",\"PeriodicalId\":22095,\"journal\":{\"name\":\"Surgical Innovation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-04-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Surgical Innovation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15533506241248974\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Innovation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15533506241248974","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

导言喉返神经(RNL)识别是甲状腺切除术的标准。术中神经监测(IONM)作为喉返神经功能评估的补充工具已被引入。本研究旨在确定 IONM 的常规使用如何影响甲状腺切除术的学习曲线(LC):A 组包括由 3 名不同住院医师实施的 150 例未使用 IONM 的甲状腺切除术,B 组包括由其他 3 名不同住院医师实施的 150 例常规使用间歇性 IONM 的手术。通过比较手术时间(OT)、LC发展过程中的稳定性以及围手术期并发症发生率来衡量LC。同样,两组之间以及独立匹配的亚组之间,在OT和并发症方面也没有明显差异,即使在比较RLN麻痹时也是如此。各组的神经直视率和 IONM 评估率相当,没有双侧 RLN 麻痹(暂时性或永久性)的报告。结论该研究表明,尽管需要对经验丰富的外科医生进行专门培训,但使用IONM甲状腺手术并不会特别影响住院医师对此类手术的学习曲线,因此即使是对受训者,也应鼓励其常规使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Impact of Intermittent Intraoperative Neuromonitoring (IONM) on the Learning Curve for Total Thyroidectomy by Residents in General Surgery
IntroductionRecurrent laryngeal nerve (RNL) identification constitutes the standard in thyroidectomy. Intraoperative nerve monitoring (IONM) has been introduced as a complementary tool for RLN functionality evaluation. The aim of this study is to establish how routine use of IONM can affect the learning curve (LC) in thyroidectomy.MethodsPatients undergoing total thyroidectomy performed by surgery residents in their learning curve course in 2 academic hospitals, were divided into 2 groups: Group A, including 150 thyroidectomies performed without IONM by 3 different residents, and Group B, including 150 procedures with routine use of intermittent IONM, by other 3 different residents. LC was measured by comparing operative time (OT), its stabilization during the development of the LC, perioperative complication rate.ResultsAs previously demonstrated, the LC was achieved after 30 procedures, in both groups, with no differences due to the use of IONM. Similarly, there were no significant differences among the 2 groups, and between subgroups independently matched, for both OT and complications, even when comparing RLN palsy. Direct nerve visualization and IONM assessment rates were comparable in all groups, and no bilateral RLN palsy (transient or permanent) were reported. No case of interrupted procedure to unilateral lobectomy, due to evidence of RLN injury, was reported.ConclusionsThe study demonstrates that the use of IONM thyroid surgery, despite requiring a specific training with experienced surgeons, does not particularly affect the learning curve of residents approaching this kind of surgery, and for this reason its routine use should be encouraged even for trainees.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Surgical Innovation
Surgical Innovation 医学-外科
CiteScore
2.90
自引率
0.00%
发文量
72
审稿时长
6-12 weeks
期刊介绍: Surgical Innovation (SRI) is a peer-reviewed bi-monthly journal focusing on minimally invasive surgical techniques, new instruments such as laparoscopes and endoscopes, and new technologies. SRI prepares surgeons to think and work in "the operating room of the future" through learning new techniques, understanding and adapting to new technologies, maintaining surgical competencies, and applying surgical outcomes data to their practices. This journal is a member of the Committee on Publication Ethics (COPE).
期刊最新文献
The Use of the Symani Surgical System® in Emergency Hand Trauma Care. A Prospective Study on a Suture Force Feedback Device for Training and Evaluating Junior Surgeons in Anastomotic Surgical Closure. The Reconstructive Metaverse - Collaboration in Real-Time Shared Mixed Reality Environments for Microsurgical Reconstruction. Patients Engaged in Losing Weight Preoperatively Experience Improved Outcomes After Hiatal Hernia Repair. Metrics for Success in a Surgical Innovation Fellowship.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1