乳腺 X 线造影术、放射医师和患者因素对诊断性乳腺 X 线造影术中良性(BI-RADS 3)评估可能性的影响。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-04-24 DOI:10.1093/jbi/wbae014
Allyson L Chesebro, Nooshin Abbasi, Ronilda C. Lacson, S. Chikarmane, Andro Licaros, C. Giess
{"title":"乳腺 X 线造影术、放射医师和患者因素对诊断性乳腺 X 线造影术中良性(BI-RADS 3)评估可能性的影响。","authors":"Allyson L Chesebro, Nooshin Abbasi, Ronilda C. Lacson, S. Chikarmane, Andro Licaros, C. Giess","doi":"10.1093/jbi/wbae014","DOIUrl":null,"url":null,"abstract":"OBJECTIVE\nTo evaluate the association of mammographic, radiologist, and patient factors on BI-RADS 3 assessment at diagnostic mammography in patients recalled from screening mammography.\n\n\nMETHODS\nThis Institutional Review Board-approved retrospective study of consecutive unique diagnostic mammography examinations in asymptomatic patients recalled from screening mammography March 5, 2014, to December 31, 2019, was conducted in a single large United States health care institution. Mammographic features (mass, calcification, distortion, asymmetry), breast density, prior examination, and BI-RADS assessment were extracted from reports by natural language processing. Patient age, race, and ethnicity were extracted from the electronic health record. Radiologist years in practice, recall rate, and number of interpreted diagnostic mammograms were calculated. A mixed effect logistic regression model evaluated factors associated with likelihood of BI-RADS 3 compared with other BI-RADS assessments.\n\n\nRESULTS\nA total of 12 080 diagnostic mammography examinations were performed during the study period, yielding 2010 (16.6%) BI-RADS 3 and 10 070 (83.4%) other BI-RADS assessments. Asymmetry (odds ratio [OR] = 6.49, P <.001) and calcification (OR = 5.59, P <.001) were associated with increased likelihood of BI-RADS 3 assessment; distortion (OR = 0.20, P <.001), dense breast parenchyma (OR = 0.82, P <.001), prior examination (OR = 0.63, P = .01), and increasing patient age (OR = 0.99, P <.001) were associated with decreased likelihood. Mass, patient race or ethnicity, and radiologist factors were not significantly associated with BI-RADS 3 assessment. Malignancy rate for BI-RADS 3 lesions was 1.6%.\n\n\nCONCLUSION\nAsymmetry and calcifications had an increased likelihood of BI-RADS 3 assessment at diagnostic evaluation with low likelihood of malignancy, while radiologist features had no association.","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Impact of Mammographic, Radiologist, and Patient Factors on the Likelihood of Probably Benign (BI-RADS 3) Assessment at Diagnostic Mammography.\",\"authors\":\"Allyson L Chesebro, Nooshin Abbasi, Ronilda C. Lacson, S. Chikarmane, Andro Licaros, C. Giess\",\"doi\":\"10.1093/jbi/wbae014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"OBJECTIVE\\nTo evaluate the association of mammographic, radiologist, and patient factors on BI-RADS 3 assessment at diagnostic mammography in patients recalled from screening mammography.\\n\\n\\nMETHODS\\nThis Institutional Review Board-approved retrospective study of consecutive unique diagnostic mammography examinations in asymptomatic patients recalled from screening mammography March 5, 2014, to December 31, 2019, was conducted in a single large United States health care institution. Mammographic features (mass, calcification, distortion, asymmetry), breast density, prior examination, and BI-RADS assessment were extracted from reports by natural language processing. Patient age, race, and ethnicity were extracted from the electronic health record. Radiologist years in practice, recall rate, and number of interpreted diagnostic mammograms were calculated. A mixed effect logistic regression model evaluated factors associated with likelihood of BI-RADS 3 compared with other BI-RADS assessments.\\n\\n\\nRESULTS\\nA total of 12 080 diagnostic mammography examinations were performed during the study period, yielding 2010 (16.6%) BI-RADS 3 and 10 070 (83.4%) other BI-RADS assessments. Asymmetry (odds ratio [OR] = 6.49, P <.001) and calcification (OR = 5.59, P <.001) were associated with increased likelihood of BI-RADS 3 assessment; distortion (OR = 0.20, P <.001), dense breast parenchyma (OR = 0.82, P <.001), prior examination (OR = 0.63, P = .01), and increasing patient age (OR = 0.99, P <.001) were associated with decreased likelihood. Mass, patient race or ethnicity, and radiologist factors were not significantly associated with BI-RADS 3 assessment. Malignancy rate for BI-RADS 3 lesions was 1.6%.\\n\\n\\nCONCLUSION\\nAsymmetry and calcifications had an increased likelihood of BI-RADS 3 assessment at diagnostic evaluation with low likelihood of malignancy, while radiologist features had no association.\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-04-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/jbi/wbae014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jbi/wbae014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

目的评估乳腺X线摄影、放射医师和患者因素与乳腺X线摄影筛查召回患者诊断性乳腺X线摄影的BI-RADS 3评估之间的关联。方法在美国一家大型医疗机构对2014年3月5日至2019年12月31日期间乳腺X线摄影筛查召回的无症状患者的连续独特诊断性乳腺X线摄影检查进行了机构审查委员会批准的回顾性研究。通过自然语言处理从报告中提取了乳腺X光特征(肿块、钙化、变形、不对称)、乳腺密度、之前的检查和BI-RADS评估。患者的年龄、种族和民族是从电子健康记录中提取的。计算了放射科医生的执业年限、召回率和诊断性乳房 X 线照片的解释次数。混合效应逻辑回归模型评估了 BI-RADS 3 与其他 BI-RADS 评估的相关因素。结果在研究期间共进行了 12 080 次诊断性乳腺 X 光检查,其中 2010 次(16.6%)为 BI-RADS 3,10 070 次(83.4%)为其他 BI-RADS 评估。不对称(几率比 [OR] = 6.49,P <.001)和钙化(OR = 5.59,P <.001)与 BI-RADS 3 评估的可能性增加有关;扭曲(OR = 0.20,P <.001)、致密乳腺实质(OR = 0.82,P <.001)、先前检查(OR = 0.63,P = .01)和患者年龄增加(OR = 0.99,P <.001)与可能性降低有关。质量、患者种族或民族以及放射医师因素与 BI-RADS 3 评估无明显关联。结论诊断评估时,不对称和钙化增加了 BI-RADS 3 评估的可能性,但恶性的可能性较低,而放射医师的特征与之无关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Impact of Mammographic, Radiologist, and Patient Factors on the Likelihood of Probably Benign (BI-RADS 3) Assessment at Diagnostic Mammography.
OBJECTIVE To evaluate the association of mammographic, radiologist, and patient factors on BI-RADS 3 assessment at diagnostic mammography in patients recalled from screening mammography. METHODS This Institutional Review Board-approved retrospective study of consecutive unique diagnostic mammography examinations in asymptomatic patients recalled from screening mammography March 5, 2014, to December 31, 2019, was conducted in a single large United States health care institution. Mammographic features (mass, calcification, distortion, asymmetry), breast density, prior examination, and BI-RADS assessment were extracted from reports by natural language processing. Patient age, race, and ethnicity were extracted from the electronic health record. Radiologist years in practice, recall rate, and number of interpreted diagnostic mammograms were calculated. A mixed effect logistic regression model evaluated factors associated with likelihood of BI-RADS 3 compared with other BI-RADS assessments. RESULTS A total of 12 080 diagnostic mammography examinations were performed during the study period, yielding 2010 (16.6%) BI-RADS 3 and 10 070 (83.4%) other BI-RADS assessments. Asymmetry (odds ratio [OR] = 6.49, P <.001) and calcification (OR = 5.59, P <.001) were associated with increased likelihood of BI-RADS 3 assessment; distortion (OR = 0.20, P <.001), dense breast parenchyma (OR = 0.82, P <.001), prior examination (OR = 0.63, P = .01), and increasing patient age (OR = 0.99, P <.001) were associated with decreased likelihood. Mass, patient race or ethnicity, and radiologist factors were not significantly associated with BI-RADS 3 assessment. Malignancy rate for BI-RADS 3 lesions was 1.6%. CONCLUSION Asymmetry and calcifications had an increased likelihood of BI-RADS 3 assessment at diagnostic evaluation with low likelihood of malignancy, while radiologist features had no association.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1