扭曲钢丝配置对外固定器稳定性的影响:生物力学研究

Alaa A. Najim, S. Hamandi, Ahmed Alzubaidi
{"title":"扭曲钢丝配置对外固定器稳定性的影响:生物力学研究","authors":"Alaa A. Najim, S. Hamandi, Ahmed Alzubaidi","doi":"10.3991/ijoe.v20i06.47293","DOIUrl":null,"url":null,"abstract":"The Ilizarov fixator is a type of external fixator that is used to treat patients who have suffered injuries from accidents, bone shortening, or nonunion of the bone. The principle behind the Ilizarov fixator is that thin wires (called Kirschner wires) are used to support the bones and connect them to framed rings. Before being fastened to the rings, the wires are tensioned and drilled through the bones. This study suggests using a new parallel wires configuration at the same level on the same ring and two revised versions, which are divergent and convergent models, and compare them with standard wires, 60 angle wires model. All models were designed using SolidWorks, a computer-aided design (CAD) software, and then analyzed in four conditions (axial compression, medial bending, posterior bending, and torsion) with Finite Element Analysis (FEA) using Ansys Workbench 2020 R2. Mechanical testing was conducted to validate the FEA results, A simple model consisting of a single ring, two K-wires, and polylactic acid (PLA) cylinders was utilized in a tensile test. It has been concluded from the results that the parallel model and its improvement have higher stiffness to axial compression, medial bending, and torsion, but a lower posterior bending stiffness, except the divergent model with 8-hole separation which has a relatively acceptable stiffness for posterior bending.","PeriodicalId":507997,"journal":{"name":"International Journal of Online and Biomedical Engineering (iJOE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Effect of Twisted Wire Configuration on the Stability of External Fixator: A Biomechanical Study\",\"authors\":\"Alaa A. Najim, S. Hamandi, Ahmed Alzubaidi\",\"doi\":\"10.3991/ijoe.v20i06.47293\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The Ilizarov fixator is a type of external fixator that is used to treat patients who have suffered injuries from accidents, bone shortening, or nonunion of the bone. The principle behind the Ilizarov fixator is that thin wires (called Kirschner wires) are used to support the bones and connect them to framed rings. Before being fastened to the rings, the wires are tensioned and drilled through the bones. This study suggests using a new parallel wires configuration at the same level on the same ring and two revised versions, which are divergent and convergent models, and compare them with standard wires, 60 angle wires model. All models were designed using SolidWorks, a computer-aided design (CAD) software, and then analyzed in four conditions (axial compression, medial bending, posterior bending, and torsion) with Finite Element Analysis (FEA) using Ansys Workbench 2020 R2. Mechanical testing was conducted to validate the FEA results, A simple model consisting of a single ring, two K-wires, and polylactic acid (PLA) cylinders was utilized in a tensile test. It has been concluded from the results that the parallel model and its improvement have higher stiffness to axial compression, medial bending, and torsion, but a lower posterior bending stiffness, except the divergent model with 8-hole separation which has a relatively acceptable stiffness for posterior bending.\",\"PeriodicalId\":507997,\"journal\":{\"name\":\"International Journal of Online and Biomedical Engineering (iJOE)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Online and Biomedical Engineering (iJOE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3991/ijoe.v20i06.47293\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Online and Biomedical Engineering (iJOE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3991/ijoe.v20i06.47293","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

伊利扎洛夫外固定器是一种外固定器,用于治疗因意外受伤、骨骼缩短或骨骼不愈合的患者。伊利扎洛夫固定器的原理是用细线(称为 Kirschner 线)支撑骨骼并将其连接到框架环上。在固定到固定环之前,先将钢丝拉紧并钻入骨头。本研究建议在同一骨环上的同一水平面上使用一种新的平行钢丝配置,以及两个修订版本,即发散型和收敛型模型,并将其与标准钢丝、60 角钢丝模型进行比较。所有模型均使用计算机辅助设计(CAD)软件 SolidWorks 进行设计,然后使用 Ansys Workbench 2020 R2 进行有限元分析(FEA),对四种情况(轴向压缩、内侧弯曲、后方弯曲和扭转)进行分析。为验证有限元分析结果,还进行了机械测试,在拉伸测试中使用了由单个环、两条 K 线和聚乳酸(PLA)圆柱体组成的简单模型。结果表明,平行模型及其改进型对轴向压缩、内侧弯曲和扭转的刚度较高,但对后侧弯曲的刚度较低,只有 8 孔分离的发散模型对后侧弯曲的刚度相对可以接受。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Effect of Twisted Wire Configuration on the Stability of External Fixator: A Biomechanical Study
The Ilizarov fixator is a type of external fixator that is used to treat patients who have suffered injuries from accidents, bone shortening, or nonunion of the bone. The principle behind the Ilizarov fixator is that thin wires (called Kirschner wires) are used to support the bones and connect them to framed rings. Before being fastened to the rings, the wires are tensioned and drilled through the bones. This study suggests using a new parallel wires configuration at the same level on the same ring and two revised versions, which are divergent and convergent models, and compare them with standard wires, 60 angle wires model. All models were designed using SolidWorks, a computer-aided design (CAD) software, and then analyzed in four conditions (axial compression, medial bending, posterior bending, and torsion) with Finite Element Analysis (FEA) using Ansys Workbench 2020 R2. Mechanical testing was conducted to validate the FEA results, A simple model consisting of a single ring, two K-wires, and polylactic acid (PLA) cylinders was utilized in a tensile test. It has been concluded from the results that the parallel model and its improvement have higher stiffness to axial compression, medial bending, and torsion, but a lower posterior bending stiffness, except the divergent model with 8-hole separation which has a relatively acceptable stiffness for posterior bending.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
XAI-PhD: Fortifying Trust of Phishing URL Detection Empowered by Shapley Additive Explanations Improving the Accuracy of Oncology Diagnosis: A Machine Learning-Based Approach to Cancer Prediction Social Robots, Mindfulness, and Kindergarten Blockchain of Things for Securing and Managing Water 4.0 Applications Intelligent Interconnected Healthcare System: Integrating IoT and Big Data for Personalized Patient Care
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1