通过基于遗传算法的模糊逻辑控制器优化 1 型糖尿病患者的血糖调节,同时考虑大量进餐方案

Isah Ndakara Abubakar, Moad Essabbar, Hajar Saikouk
{"title":"通过基于遗传算法的模糊逻辑控制器优化 1 型糖尿病患者的血糖调节,同时考虑大量进餐方案","authors":"Isah Ndakara Abubakar, Moad Essabbar, Hajar Saikouk","doi":"10.3991/ijoe.v20i06.46929","DOIUrl":null,"url":null,"abstract":"Effective management of blood glucose levels in individuals with type 1 diabetes, especially after meals, is crucial for diabetes care. Artificial pancreas systems (APS) perform automated insulin delivery in subjects with type 1 diabetes mellitus (T1DM). In this study, an optimized fuzzy logic controller was designed to achieve a euglycemic range after a substantial meal intake. All in silico simulations were performed using the MATLAB/Simulink environment, leveraging control variability grid analysis (CVGA), and the performance of the controller was evaluated. The proposed controller is based on a fuzzy-logic control law designed in three stages. First, a nonlinear framework of the glucose-insulin regulatory system was identified based on the heavy meal protocol of three patients given as follows: for subject ID 117-1, a total of 295 gCHO; for subject ID 126-1, 236 gCHO; and subject ID 128-1, 394 gCHO over a day. Then, an iterative tree structure was employed to establish a stabilizing control rule for insulin delivery, integrating inputs from two Mamdani Fuzzy Inference System (FIS) objects. Finally, a genetic algorithm refines the control system by fine-tuning the uncertainty of the fuzzy membership functions. Two scenarios were considered for three patients to assess the performance of the proposed controller. The results indicated its effectiveness under various conditions, achieving a time in the range of 61.25%, 71% and 61.10% respectively for the three subjects. The obtained results are analyzed and compared with IMC and multi-objective output feedback controllers. The findings of the study reveal that the proposed controller shows promising advancements in tailored strategies for type 1 diabetes patients, outperforming the other controllers in terms of blood glucose regulation.","PeriodicalId":507997,"journal":{"name":"International Journal of Online and Biomedical Engineering (iJOE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Optimizing Blood Glucose Regulation in Type 1 Diabetes Patients via Genetic Algorithm-Based Fuzzy Logic Controller Considering Substantial Meal Protocol\",\"authors\":\"Isah Ndakara Abubakar, Moad Essabbar, Hajar Saikouk\",\"doi\":\"10.3991/ijoe.v20i06.46929\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Effective management of blood glucose levels in individuals with type 1 diabetes, especially after meals, is crucial for diabetes care. Artificial pancreas systems (APS) perform automated insulin delivery in subjects with type 1 diabetes mellitus (T1DM). In this study, an optimized fuzzy logic controller was designed to achieve a euglycemic range after a substantial meal intake. All in silico simulations were performed using the MATLAB/Simulink environment, leveraging control variability grid analysis (CVGA), and the performance of the controller was evaluated. The proposed controller is based on a fuzzy-logic control law designed in three stages. First, a nonlinear framework of the glucose-insulin regulatory system was identified based on the heavy meal protocol of three patients given as follows: for subject ID 117-1, a total of 295 gCHO; for subject ID 126-1, 236 gCHO; and subject ID 128-1, 394 gCHO over a day. Then, an iterative tree structure was employed to establish a stabilizing control rule for insulin delivery, integrating inputs from two Mamdani Fuzzy Inference System (FIS) objects. Finally, a genetic algorithm refines the control system by fine-tuning the uncertainty of the fuzzy membership functions. Two scenarios were considered for three patients to assess the performance of the proposed controller. The results indicated its effectiveness under various conditions, achieving a time in the range of 61.25%, 71% and 61.10% respectively for the three subjects. The obtained results are analyzed and compared with IMC and multi-objective output feedback controllers. The findings of the study reveal that the proposed controller shows promising advancements in tailored strategies for type 1 diabetes patients, outperforming the other controllers in terms of blood glucose regulation.\",\"PeriodicalId\":507997,\"journal\":{\"name\":\"International Journal of Online and Biomedical Engineering (iJOE)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Online and Biomedical Engineering (iJOE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3991/ijoe.v20i06.46929\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Online and Biomedical Engineering (iJOE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3991/ijoe.v20i06.46929","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

有效控制 1 型糖尿病患者的血糖水平,尤其是餐后血糖水平,对糖尿病护理至关重要。人工胰腺系统(APS)可为 1 型糖尿病患者自动输送胰岛素。在这项研究中,设计了一种优化的模糊逻辑控制器,以便在大量进餐后达到优生血糖范围。使用 MATLAB/Simulink 环境,利用控制变异性网格分析 (CVGA) 进行了所有硅模拟,并对控制器的性能进行了评估。所提出的控制器是基于模糊逻辑控制法设计的,分为三个阶段。首先,根据三位患者的大餐方案确定了葡萄糖-胰岛素调节系统的非线性框架:受试者编号 117-1,一天共进食 295 gCHO;受试者编号 126-1,一天共进食 236 gCHO;受试者编号 128-1,一天共进食 394 gCHO。然后,采用迭代树结构建立胰岛素输送的稳定控制规则,整合两个马姆达尼模糊推理系统(FIS)对象的输入。最后,遗传算法通过微调模糊成员函数的不确定性来完善控制系统。为评估拟议控制器的性能,对三名患者的两种情况进行了考虑。结果表明,该控制器在各种条件下都很有效,三个受试者的时间分别达到了 61.25%、71% 和 61.10%。获得的结果与 IMC 和多目标输出反馈控制器进行了分析和比较。研究结果表明,所提出的控制器在为 1 型糖尿病患者量身定制策略方面取得了可喜的进步,在血糖调节方面优于其他控制器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optimizing Blood Glucose Regulation in Type 1 Diabetes Patients via Genetic Algorithm-Based Fuzzy Logic Controller Considering Substantial Meal Protocol
Effective management of blood glucose levels in individuals with type 1 diabetes, especially after meals, is crucial for diabetes care. Artificial pancreas systems (APS) perform automated insulin delivery in subjects with type 1 diabetes mellitus (T1DM). In this study, an optimized fuzzy logic controller was designed to achieve a euglycemic range after a substantial meal intake. All in silico simulations were performed using the MATLAB/Simulink environment, leveraging control variability grid analysis (CVGA), and the performance of the controller was evaluated. The proposed controller is based on a fuzzy-logic control law designed in three stages. First, a nonlinear framework of the glucose-insulin regulatory system was identified based on the heavy meal protocol of three patients given as follows: for subject ID 117-1, a total of 295 gCHO; for subject ID 126-1, 236 gCHO; and subject ID 128-1, 394 gCHO over a day. Then, an iterative tree structure was employed to establish a stabilizing control rule for insulin delivery, integrating inputs from two Mamdani Fuzzy Inference System (FIS) objects. Finally, a genetic algorithm refines the control system by fine-tuning the uncertainty of the fuzzy membership functions. Two scenarios were considered for three patients to assess the performance of the proposed controller. The results indicated its effectiveness under various conditions, achieving a time in the range of 61.25%, 71% and 61.10% respectively for the three subjects. The obtained results are analyzed and compared with IMC and multi-objective output feedback controllers. The findings of the study reveal that the proposed controller shows promising advancements in tailored strategies for type 1 diabetes patients, outperforming the other controllers in terms of blood glucose regulation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
XAI-PhD: Fortifying Trust of Phishing URL Detection Empowered by Shapley Additive Explanations Improving the Accuracy of Oncology Diagnosis: A Machine Learning-Based Approach to Cancer Prediction Social Robots, Mindfulness, and Kindergarten Blockchain of Things for Securing and Managing Water 4.0 Applications Intelligent Interconnected Healthcare System: Integrating IoT and Big Data for Personalized Patient Care
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1