过冷入口对微小通道水流沸腾传热影响的数值研究

A. Al-Waaly
{"title":"过冷入口对微小通道水流沸腾传热影响的数值研究","authors":"A. Al-Waaly","doi":"10.31185/ejuow.vol12.iss2.531","DOIUrl":null,"url":null,"abstract":"The effect of subcooling inlet has a big effect of the flow patterns for the flow boiling through a microchannel. Higher subcooling lower mass flux will delay the nucleate boiling and vice versa. The water flow boiling inside a microchannel has been analyzed numerically. The microchannel depth was 0.24 mm while the length was 40 mm. The supplied heat fluxes were 500 kW·m-2, 1000 kW·m-2and 1500 kW·m-2 with mass velocities of 400 kg·m-2·s-1 and 800 kg·m-2·s-1. The degrees of subcoooling of inlet water were 5oC, 10oC, 15oC, 20oC, and 25oC. The results showed that the degree subcooling has a considerable impact on both the wall temperature and flow patterns. The rise in the degree of subcooling kept the nucleate flow boiling and retarded the development of convective boiling. In addition, there was a reflection point at which the impact of heat flux on the average of the convective coefficient of heat transfer was altered. The increase in the heat flux may lead to an increase or reduction in the average HTC with respect to the location of the reflection point. The reflection points were 7oC and 5oC for the mass velocities 400 kg·m-2·s-1 and 800 kg·m-2·s-1. Thus, both the degree of subcooling and the heat flux should be simultaneously considered when it comes to the enhancement of HTC during the flow boiling inside the microchannels.","PeriodicalId":184256,"journal":{"name":"Wasit Journal of Engineering Sciences","volume":"21 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Numerical Investigation of the Impact of Subcooling Inlet on Water Flow Boiling Heat Transfer Through a Microchannel\",\"authors\":\"A. Al-Waaly\",\"doi\":\"10.31185/ejuow.vol12.iss2.531\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The effect of subcooling inlet has a big effect of the flow patterns for the flow boiling through a microchannel. Higher subcooling lower mass flux will delay the nucleate boiling and vice versa. The water flow boiling inside a microchannel has been analyzed numerically. The microchannel depth was 0.24 mm while the length was 40 mm. The supplied heat fluxes were 500 kW·m-2, 1000 kW·m-2and 1500 kW·m-2 with mass velocities of 400 kg·m-2·s-1 and 800 kg·m-2·s-1. The degrees of subcoooling of inlet water were 5oC, 10oC, 15oC, 20oC, and 25oC. The results showed that the degree subcooling has a considerable impact on both the wall temperature and flow patterns. The rise in the degree of subcooling kept the nucleate flow boiling and retarded the development of convective boiling. In addition, there was a reflection point at which the impact of heat flux on the average of the convective coefficient of heat transfer was altered. The increase in the heat flux may lead to an increase or reduction in the average HTC with respect to the location of the reflection point. The reflection points were 7oC and 5oC for the mass velocities 400 kg·m-2·s-1 and 800 kg·m-2·s-1. Thus, both the degree of subcooling and the heat flux should be simultaneously considered when it comes to the enhancement of HTC during the flow boiling inside the microchannels.\",\"PeriodicalId\":184256,\"journal\":{\"name\":\"Wasit Journal of Engineering Sciences\",\"volume\":\"21 \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Wasit Journal of Engineering Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31185/ejuow.vol12.iss2.531\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wasit Journal of Engineering Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31185/ejuow.vol12.iss2.531","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

入口过冷度对通过微通道的沸腾流的流动模式有很大影响。过冷度越高,质量通量越低,成核沸腾越晚,反之亦然。我们对微通道内的水流沸腾进行了数值分析。微通道深度为 0.24 毫米,长度为 40 毫米。提供的热通量分别为 500 kW-m-2、1000 kW-m-2 和 1500 kW-m-2,质量速度分别为 400 kg-m-2-s-1 和 800 kg-m-2-s-1。进水过冷度分别为 5oC、10oC、15oC、20oC 和 25oC。结果表明,过冷度对壁面温度和流动模式都有相当大的影响。过冷度的升高保持了核流动沸腾,延缓了对流沸腾的发展。此外,热通量对对流传热系数平均值的影响在一个反射点上发生了变化。热通量的增加可能会导致相对于反射点位置的 HTC 平均值的增加或减少。在质量速度为 400 kg-m-2-s-1 和 800 kg-m-2-s-1 时,反射点分别为 7oC 和 5oC。因此,在微通道内流动沸腾过程中提高 HTC 时,应同时考虑过冷度和热通量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Numerical Investigation of the Impact of Subcooling Inlet on Water Flow Boiling Heat Transfer Through a Microchannel
The effect of subcooling inlet has a big effect of the flow patterns for the flow boiling through a microchannel. Higher subcooling lower mass flux will delay the nucleate boiling and vice versa. The water flow boiling inside a microchannel has been analyzed numerically. The microchannel depth was 0.24 mm while the length was 40 mm. The supplied heat fluxes were 500 kW·m-2, 1000 kW·m-2and 1500 kW·m-2 with mass velocities of 400 kg·m-2·s-1 and 800 kg·m-2·s-1. The degrees of subcoooling of inlet water were 5oC, 10oC, 15oC, 20oC, and 25oC. The results showed that the degree subcooling has a considerable impact on both the wall temperature and flow patterns. The rise in the degree of subcooling kept the nucleate flow boiling and retarded the development of convective boiling. In addition, there was a reflection point at which the impact of heat flux on the average of the convective coefficient of heat transfer was altered. The increase in the heat flux may lead to an increase or reduction in the average HTC with respect to the location of the reflection point. The reflection points were 7oC and 5oC for the mass velocities 400 kg·m-2·s-1 and 800 kg·m-2·s-1. Thus, both the degree of subcooling and the heat flux should be simultaneously considered when it comes to the enhancement of HTC during the flow boiling inside the microchannels.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Efficient Dye Removal and Water Treatment Feasibility Assessment for Iraq's Industrial Sector: A Case Study on Terasil Blue Dye Treatment Using Inverse Fluidized Bed and Adsorption A Deep Learning Approach to Evaluating SISO-OFDM Channel Equalization Numerical Investigation of the Impact of Subcooling Inlet on Water Flow Boiling Heat Transfer Through a Microchannel Effect of Metal Foam’s Volume on the Performance of a Double Pipe heat exchanger Flow field and heat transfer characteristics in dimple pipe with different shape of dimples
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1