金属泡沫体积对双管热交换器性能的影响

Zuhair S. Faal, Abbas J. Jubear, Hussain R. Al-Bugharbee
{"title":"金属泡沫体积对双管热交换器性能的影响","authors":"Zuhair S. Faal, Abbas J. Jubear, Hussain R. Al-Bugharbee","doi":"10.31185/ejuow.vol12.iss2.495","DOIUrl":null,"url":null,"abstract":"The present numerical study aims to explore the effect of metal foam’s volume on the performance of a double-pipe heat exchanger in comparison with a smooth pipe (HXS). It used water as operating fluid at flow rate 2lpm, the outer stainless steel pipe has outer diameter (Do=60mm) and length (L=609.6mm), and inner copper pipe with outer diameter (do=20mm). The numerical simulation was conducted by ANSYS FLUENT 2020 R2 software and open-cell copper foam (CF) with porosity (0.9) was used. The cases considered in the analysis include a heat exchanger with a complete fill of copper foam (HXF), and  a partial fill heat exchanger. The latter was made by inserting a complete rings of copper foam baffles (CFB) to decrease volume of a CF. Then, the baffles volumes was increased by increasing the thickness and their number.  Three parameters were varied and their influence on performance evaluate criteria (PEC) were investigated. They are pore density (PPI), thickness of baffles (tc), and number of baffles (nob). Results showed that, heat transfer rate (Qave) and the pressure drop (∆p) increased with increase pore density, and well distribution of a CFB increase thermal performance while the pressure drop did not change with use same volume of CF.","PeriodicalId":184256,"journal":{"name":"Wasit Journal of Engineering Sciences","volume":"82 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Metal Foam’s Volume on the Performance of a Double Pipe heat exchanger\",\"authors\":\"Zuhair S. Faal, Abbas J. Jubear, Hussain R. Al-Bugharbee\",\"doi\":\"10.31185/ejuow.vol12.iss2.495\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The present numerical study aims to explore the effect of metal foam’s volume on the performance of a double-pipe heat exchanger in comparison with a smooth pipe (HXS). It used water as operating fluid at flow rate 2lpm, the outer stainless steel pipe has outer diameter (Do=60mm) and length (L=609.6mm), and inner copper pipe with outer diameter (do=20mm). The numerical simulation was conducted by ANSYS FLUENT 2020 R2 software and open-cell copper foam (CF) with porosity (0.9) was used. The cases considered in the analysis include a heat exchanger with a complete fill of copper foam (HXF), and  a partial fill heat exchanger. The latter was made by inserting a complete rings of copper foam baffles (CFB) to decrease volume of a CF. Then, the baffles volumes was increased by increasing the thickness and their number.  Three parameters were varied and their influence on performance evaluate criteria (PEC) were investigated. They are pore density (PPI), thickness of baffles (tc), and number of baffles (nob). Results showed that, heat transfer rate (Qave) and the pressure drop (∆p) increased with increase pore density, and well distribution of a CFB increase thermal performance while the pressure drop did not change with use same volume of CF.\",\"PeriodicalId\":184256,\"journal\":{\"name\":\"Wasit Journal of Engineering Sciences\",\"volume\":\"82 \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Wasit Journal of Engineering Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31185/ejuow.vol12.iss2.495\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wasit Journal of Engineering Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31185/ejuow.vol12.iss2.495","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本数值研究旨在探讨与光滑管(HXS)相比,金属泡沫体积对双管热交换器性能的影响。它使用水作为工作流体,流速为 2lpm,外层不锈钢管的外径(Do=60 毫米)和长度(L=609.6 毫米),内层铜管的外径(do=20 毫米)。数值模拟由 ANSYS FLUENT 2020 R2 软件进行,使用孔隙率为 0.9 的开孔泡沫铜(CF)。分析中考虑的情况包括完全填充泡沫铜(HXF)的热交换器和部分填充热交换器。后者是通过插入一个完整的环形泡沫铜挡板(CFB)来减少 CF 的体积。然后,通过增加挡板的厚度和数量来增大挡板的体积。 我们改变了三个参数,并研究了它们对性能评估标准(PEC)的影响。它们分别是孔密度(PPI)、挡板厚度(tc)和挡板数量(nob)。结果表明,传热率(Qave)和压降(Δp)随孔隙密度的增加而增加,CFB 的良好分布提高了热性能,而在使用相同体积的 CF 时,压降没有变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Effect of Metal Foam’s Volume on the Performance of a Double Pipe heat exchanger
The present numerical study aims to explore the effect of metal foam’s volume on the performance of a double-pipe heat exchanger in comparison with a smooth pipe (HXS). It used water as operating fluid at flow rate 2lpm, the outer stainless steel pipe has outer diameter (Do=60mm) and length (L=609.6mm), and inner copper pipe with outer diameter (do=20mm). The numerical simulation was conducted by ANSYS FLUENT 2020 R2 software and open-cell copper foam (CF) with porosity (0.9) was used. The cases considered in the analysis include a heat exchanger with a complete fill of copper foam (HXF), and  a partial fill heat exchanger. The latter was made by inserting a complete rings of copper foam baffles (CFB) to decrease volume of a CF. Then, the baffles volumes was increased by increasing the thickness and their number.  Three parameters were varied and their influence on performance evaluate criteria (PEC) were investigated. They are pore density (PPI), thickness of baffles (tc), and number of baffles (nob). Results showed that, heat transfer rate (Qave) and the pressure drop (∆p) increased with increase pore density, and well distribution of a CFB increase thermal performance while the pressure drop did not change with use same volume of CF.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Efficient Dye Removal and Water Treatment Feasibility Assessment for Iraq's Industrial Sector: A Case Study on Terasil Blue Dye Treatment Using Inverse Fluidized Bed and Adsorption A Deep Learning Approach to Evaluating SISO-OFDM Channel Equalization Numerical Investigation of the Impact of Subcooling Inlet on Water Flow Boiling Heat Transfer Through a Microchannel Effect of Metal Foam’s Volume on the Performance of a Double Pipe heat exchanger Flow field and heat transfer characteristics in dimple pipe with different shape of dimples
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1