用于估算分子放射治疗吸收剂量的高分辨率便携式伽马相机

IF 4.6 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING IEEE Transactions on Radiation and Plasma Medical Sciences Pub Date : 2024-03-13 DOI:10.1109/TRPMS.2024.3376826
T. Bossis;M.-A. Verdier;C. Trigila;L. Pinot;F. Bouvet;A. Blot;H. Ramarijaona;T. Beaumont;D. Broggio;O. Caselles;S. Zerdoud;L. Ménard
{"title":"用于估算分子放射治疗吸收剂量的高分辨率便携式伽马相机","authors":"T. Bossis;M.-A. Verdier;C. Trigila;L. Pinot;F. Bouvet;A. Blot;H. Ramarijaona;T. Beaumont;D. Broggio;O. Caselles;S. Zerdoud;L. Ménard","doi":"10.1109/TRPMS.2024.3376826","DOIUrl":null,"url":null,"abstract":"Molecular radiotherapy is a treatment modality that requires personalized dosimetry for efficient treatment and reduced toxicity. Current clinical imaging systems and miniaturized gamma-cameras lack the necessary features for this task. In this article, we present the design and optimization of a mobile gamma-camera with a \n<inline-formula> <tex-math>$10\\times 10$ </tex-math></inline-formula>\n cm2 field of view tailored for quantitative imaging during \n<inline-formula> <tex-math>$^{131}\\text{I}$ </tex-math></inline-formula>\n therapy of thyroid diseases. The camera uses a monolithic \n<inline-formula> <tex-math>$10\\times 10\\times 1$ </tex-math></inline-formula>\n cm3 CeBr3 scintillator coupled to a \n<inline-formula> <tex-math>$16\\times 16$ </tex-math></inline-formula>\n SiPMs array and commercial electronics. It exhibits high imaging performance with an intrinsic spatial resolution (SR) of 1.15-mm FWHM, an energy resolution of 8% FWHM at 356 keV and negligible deadtime up to 150 kcps. Images are reconstructed in real time using a convolutional neural network. The manufacturing method of tungsten collimators and shielding was optimized using laser 3-D printing to achieve an effective density of 97% that of bulk tungsten. Their geometry was adjusted with Monte-Carlo simulations in order to reduce septal penetration and scattering and optimize the signal-to-noise ratio at short times after treatment administration. Two high-energy parallel-hole collimators with high sensitivity or very high SR were designed for treatment planning and post-treatment control. The fully operational gamma-camera will soon be clinically assessed.","PeriodicalId":46807,"journal":{"name":"IEEE Transactions on Radiation and Plasma Medical Sciences","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10472319","citationCount":"0","resultStr":"{\"title\":\"A High-Resolution Portable Gamma-Camera for Estimation of Absorbed Dose in Molecular Radiotherapy\",\"authors\":\"T. Bossis;M.-A. Verdier;C. Trigila;L. Pinot;F. Bouvet;A. Blot;H. Ramarijaona;T. Beaumont;D. Broggio;O. Caselles;S. Zerdoud;L. Ménard\",\"doi\":\"10.1109/TRPMS.2024.3376826\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Molecular radiotherapy is a treatment modality that requires personalized dosimetry for efficient treatment and reduced toxicity. Current clinical imaging systems and miniaturized gamma-cameras lack the necessary features for this task. In this article, we present the design and optimization of a mobile gamma-camera with a \\n<inline-formula> <tex-math>$10\\\\times 10$ </tex-math></inline-formula>\\n cm2 field of view tailored for quantitative imaging during \\n<inline-formula> <tex-math>$^{131}\\\\text{I}$ </tex-math></inline-formula>\\n therapy of thyroid diseases. The camera uses a monolithic \\n<inline-formula> <tex-math>$10\\\\times 10\\\\times 1$ </tex-math></inline-formula>\\n cm3 CeBr3 scintillator coupled to a \\n<inline-formula> <tex-math>$16\\\\times 16$ </tex-math></inline-formula>\\n SiPMs array and commercial electronics. It exhibits high imaging performance with an intrinsic spatial resolution (SR) of 1.15-mm FWHM, an energy resolution of 8% FWHM at 356 keV and negligible deadtime up to 150 kcps. Images are reconstructed in real time using a convolutional neural network. The manufacturing method of tungsten collimators and shielding was optimized using laser 3-D printing to achieve an effective density of 97% that of bulk tungsten. Their geometry was adjusted with Monte-Carlo simulations in order to reduce septal penetration and scattering and optimize the signal-to-noise ratio at short times after treatment administration. Two high-energy parallel-hole collimators with high sensitivity or very high SR were designed for treatment planning and post-treatment control. The fully operational gamma-camera will soon be clinically assessed.\",\"PeriodicalId\":46807,\"journal\":{\"name\":\"IEEE Transactions on Radiation and Plasma Medical Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-03-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10472319\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Transactions on Radiation and Plasma Medical Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10472319/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Radiation and Plasma Medical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10472319/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

分子放射治疗是一种需要个性化剂量测定的治疗方式,以实现高效治疗和减少毒性。目前的临床成像系统和微型伽马相机缺乏完成这项任务的必要功能。在这篇文章中,我们介绍了一种移动式伽马相机的设计和优化,它的视场为10美元/10平方厘米,专门用于甲状腺疾病的^{131}\text{I}$治疗过程中的定量成像。该相机使用了一个10美元/次 10美元/次 1立方厘米的单片CeBr3闪烁体,该闪烁体与一个16美元/次 16美元的SiPMs阵列和商用电子设备相连。它具有很高的成像性能,固有空间分辨率(SR)为 1.15 mm FWHM,在 356 keV 时的能量分辨率为 8% FWHM,死区时间可忽略不计,最高可达 150 kcps。使用卷积神经网络实时重建图像。钨准直器和屏蔽的制造方法通过激光三维打印进行了优化,使其有效密度达到块状钨的 97%。通过蒙特卡洛模拟调整了它们的几何形状,以减少隔膜穿透和散射,优化治疗后短时间内的信噪比。设计了两个高能量平行孔准直器,具有高灵敏度或极高的 SR,用于治疗计划和治疗后控制。全面运行的伽马相机不久将进行临床评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A High-Resolution Portable Gamma-Camera for Estimation of Absorbed Dose in Molecular Radiotherapy
Molecular radiotherapy is a treatment modality that requires personalized dosimetry for efficient treatment and reduced toxicity. Current clinical imaging systems and miniaturized gamma-cameras lack the necessary features for this task. In this article, we present the design and optimization of a mobile gamma-camera with a $10\times 10$ cm2 field of view tailored for quantitative imaging during $^{131}\text{I}$ therapy of thyroid diseases. The camera uses a monolithic $10\times 10\times 1$ cm3 CeBr3 scintillator coupled to a $16\times 16$ SiPMs array and commercial electronics. It exhibits high imaging performance with an intrinsic spatial resolution (SR) of 1.15-mm FWHM, an energy resolution of 8% FWHM at 356 keV and negligible deadtime up to 150 kcps. Images are reconstructed in real time using a convolutional neural network. The manufacturing method of tungsten collimators and shielding was optimized using laser 3-D printing to achieve an effective density of 97% that of bulk tungsten. Their geometry was adjusted with Monte-Carlo simulations in order to reduce septal penetration and scattering and optimize the signal-to-noise ratio at short times after treatment administration. Two high-energy parallel-hole collimators with high sensitivity or very high SR were designed for treatment planning and post-treatment control. The fully operational gamma-camera will soon be clinically assessed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEEE Transactions on Radiation and Plasma Medical Sciences
IEEE Transactions on Radiation and Plasma Medical Sciences RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
8.00
自引率
18.20%
发文量
109
期刊最新文献
Affiliate Plan of the IEEE Nuclear and Plasma Sciences Society Table of Contents Introducing IEEE Collabratec IEEE Transactions on Radiation and Plasma Medical Sciences Publication Information Member Get-a-Member (MGM) Program
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1