[通过射血时心室功率相型分析无创评估心功能]。

Journal of cardiography Pub Date : 1986-03-01
I Takahashi, Y Miyashita, K Takayama, H Fujisaki, M Hara, K Maie, K Nishida, T Nakatsuka, S Yoshimura, H Furuhata
{"title":"[通过射血时心室功率相型分析无创评估心功能]。","authors":"I Takahashi,&nbsp;Y Miyashita,&nbsp;K Takayama,&nbsp;H Fujisaki,&nbsp;M Hara,&nbsp;K Maie,&nbsp;K Nishida,&nbsp;T Nakatsuka,&nbsp;S Yoshimura,&nbsp;H Furuhata","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>To evaluate cardiac function, ventricular power during ejection (power) and the rate of change of power (dPower/dt) were assessed noninvasively. Power was determined from the product of aortic flow (Fa(t] and brachial arterial pressure (Pa(t]. Fa(t) was measured at the suprasternal notch using an ultrasonic pulsed Doppler flowmeter with a 2 MHz carrier frequency and 10 KHz repetition frequency. The maximum detectable blood velocity was 380 cm/sec. Pa(t) was measured using a newly-developed method based on indirect unloading techniques and an air pressure system. There were 21 normal subjects and seven patients with coronary artery disease in this study. The following results were obtained. There was no significant difference between power patterns calculated by Pa(t) and Pao(t) (aortic pressure measured by catheter). The average peak dPower/dt was 160.2 J/sec2 in normal subjects, 145.2 L/sec2 in patients with ejection fractions greater than 50%, and 93.5 J/sec2 in patients with ejection fraction less than 50%. Peak dPower/dt was significantly decreased in patients with the lower ejection fraction (p less than 0.005). The results indicated that this index is clinically useful in evaluating cardiac contractility.</p>","PeriodicalId":77734,"journal":{"name":"Journal of cardiography","volume":"16 1","pages":"159-70"},"PeriodicalIF":0.0000,"publicationDate":"1986-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Cardiac function noninvasively evaluated by phasic pattern analysis of ventricular power during ejection].\",\"authors\":\"I Takahashi,&nbsp;Y Miyashita,&nbsp;K Takayama,&nbsp;H Fujisaki,&nbsp;M Hara,&nbsp;K Maie,&nbsp;K Nishida,&nbsp;T Nakatsuka,&nbsp;S Yoshimura,&nbsp;H Furuhata\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>To evaluate cardiac function, ventricular power during ejection (power) and the rate of change of power (dPower/dt) were assessed noninvasively. Power was determined from the product of aortic flow (Fa(t] and brachial arterial pressure (Pa(t]. Fa(t) was measured at the suprasternal notch using an ultrasonic pulsed Doppler flowmeter with a 2 MHz carrier frequency and 10 KHz repetition frequency. The maximum detectable blood velocity was 380 cm/sec. Pa(t) was measured using a newly-developed method based on indirect unloading techniques and an air pressure system. There were 21 normal subjects and seven patients with coronary artery disease in this study. The following results were obtained. There was no significant difference between power patterns calculated by Pa(t) and Pao(t) (aortic pressure measured by catheter). The average peak dPower/dt was 160.2 J/sec2 in normal subjects, 145.2 L/sec2 in patients with ejection fractions greater than 50%, and 93.5 J/sec2 in patients with ejection fraction less than 50%. Peak dPower/dt was significantly decreased in patients with the lower ejection fraction (p less than 0.005). The results indicated that this index is clinically useful in evaluating cardiac contractility.</p>\",\"PeriodicalId\":77734,\"journal\":{\"name\":\"Journal of cardiography\",\"volume\":\"16 1\",\"pages\":\"159-70\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1986-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of cardiography\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cardiography","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了评估心功能,无创评估了射血时心室功率(power)和功率变化率(dPower/dt)。功率由主动脉流量(Fa(t))和肱动脉压(Pa(t))的乘积确定。采用载频为2 MHz、重复频率为10 KHz的超声脉冲多普勒流量计测量胸骨上切迹处Fa(t)。最大可检血速度为380厘米/秒。Pa(t)的测量采用了一种基于间接卸载技术和气压系统的新方法。正常受试者21例,冠心病患者7例。得到了以下结果:Pa(t)和Pao(t)(导管测量的主动脉压)计算的功率模式无显著差异。正常人dPower/dt平均峰值为160.2 J/sec2,射血分数大于50%的患者为145.2 L/sec2,射血分数小于50%的患者为93.5 J/sec2。射血分数较低的患者峰值dPower/dt显著降低(p < 0.005)。结果表明,该指标在临床上评价心脏收缩力是有价值的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[Cardiac function noninvasively evaluated by phasic pattern analysis of ventricular power during ejection].

To evaluate cardiac function, ventricular power during ejection (power) and the rate of change of power (dPower/dt) were assessed noninvasively. Power was determined from the product of aortic flow (Fa(t] and brachial arterial pressure (Pa(t]. Fa(t) was measured at the suprasternal notch using an ultrasonic pulsed Doppler flowmeter with a 2 MHz carrier frequency and 10 KHz repetition frequency. The maximum detectable blood velocity was 380 cm/sec. Pa(t) was measured using a newly-developed method based on indirect unloading techniques and an air pressure system. There were 21 normal subjects and seven patients with coronary artery disease in this study. The following results were obtained. There was no significant difference between power patterns calculated by Pa(t) and Pao(t) (aortic pressure measured by catheter). The average peak dPower/dt was 160.2 J/sec2 in normal subjects, 145.2 L/sec2 in patients with ejection fractions greater than 50%, and 93.5 J/sec2 in patients with ejection fraction less than 50%. Peak dPower/dt was significantly decreased in patients with the lower ejection fraction (p less than 0.005). The results indicated that this index is clinically useful in evaluating cardiac contractility.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Mechanical and electrocardiographic sequence of coronary artery occlusion: an echocardiographic study during coronary angioplasty]. [Collateral circulation during exercise-induced angina: evaluation by coronary angiography]. [Echo and Doppler cardiographic findings of isolated quadricuspid aortic valve: a case report and a review of the literature]. [Quantitative integrated backscatter characteristics in the normal and infarcted canine myocardium]. Clinical validity of washout time constant images obtained by digital subtraction angiography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1