Ahmed Elhanafy, Samir Elsagheer, Shinichi Ookawara, Sameh Nada
{"title":"带有囊状动脉瘤的弯曲微血管中细胞血流的数值模拟:弯曲度和血细胞比容水平的影响","authors":"Ahmed Elhanafy, Samir Elsagheer, Shinichi Ookawara, Sameh Nada","doi":"10.1063/5.0203220","DOIUrl":null,"url":null,"abstract":"The dynamics of cellular blood flow in curved vessels considerably differ from those in straight vessels. It is reported that clotting development is significantly affected by vessel shape irregularities. Thus, the current study aims to investigate the effect of curvature degree and hematocrit level on cellular blood flow in a curved micro-vessel with a saccular aneurysm. Accordingly, a three-dimensional numerical simulation is performed using a validated code developed for cellular blood flow problems. The obtained results show that the cell-free layer thickness is highly dependent on the curvature degree and hematocrit level, which may have a remarkable impact on the apparent viscosity of blood as well as the dynamics of other particles such as drug particulates. The near-wall region exhibits the highest degree of cell deformation, whereas the red blood cells within the aneurysm zone remain nearly undeformed. Meanwhile, the velocity of the red blood cells decreases with the increase in curvature degree, which can affect the quality of the oxygenation process. Because of the saccular aneurysm, a considerable decrease in plasma velocity is predicted. Moreover, no secondary flows are detected in the curved vessel except in the aneurysm zone. An increase in the curvature degree is expected to reduce the blood flow rate by about 10%. Furthermore, low wall shear stress values are predicted in the straight case compared to the values at the apex of the curved vessel, which may affect the structure and function of the endothelial cells of the vessel wall and, hence, increase the aneurysm rupture possibility.","PeriodicalId":8855,"journal":{"name":"Biomicrofluidics","volume":"53 1","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Numerical simulation of cellular blood flow in curved micro-vessels with saccular aneurysms: Effect of curvature degree and hematocrit level\",\"authors\":\"Ahmed Elhanafy, Samir Elsagheer, Shinichi Ookawara, Sameh Nada\",\"doi\":\"10.1063/5.0203220\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The dynamics of cellular blood flow in curved vessels considerably differ from those in straight vessels. It is reported that clotting development is significantly affected by vessel shape irregularities. Thus, the current study aims to investigate the effect of curvature degree and hematocrit level on cellular blood flow in a curved micro-vessel with a saccular aneurysm. Accordingly, a three-dimensional numerical simulation is performed using a validated code developed for cellular blood flow problems. The obtained results show that the cell-free layer thickness is highly dependent on the curvature degree and hematocrit level, which may have a remarkable impact on the apparent viscosity of blood as well as the dynamics of other particles such as drug particulates. The near-wall region exhibits the highest degree of cell deformation, whereas the red blood cells within the aneurysm zone remain nearly undeformed. Meanwhile, the velocity of the red blood cells decreases with the increase in curvature degree, which can affect the quality of the oxygenation process. Because of the saccular aneurysm, a considerable decrease in plasma velocity is predicted. Moreover, no secondary flows are detected in the curved vessel except in the aneurysm zone. An increase in the curvature degree is expected to reduce the blood flow rate by about 10%. Furthermore, low wall shear stress values are predicted in the straight case compared to the values at the apex of the curved vessel, which may affect the structure and function of the endothelial cells of the vessel wall and, hence, increase the aneurysm rupture possibility.\",\"PeriodicalId\":8855,\"journal\":{\"name\":\"Biomicrofluidics\",\"volume\":\"53 1\",\"pages\":\"\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-04-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomicrofluidics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0203220\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomicrofluidics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1063/5.0203220","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Numerical simulation of cellular blood flow in curved micro-vessels with saccular aneurysms: Effect of curvature degree and hematocrit level
The dynamics of cellular blood flow in curved vessels considerably differ from those in straight vessels. It is reported that clotting development is significantly affected by vessel shape irregularities. Thus, the current study aims to investigate the effect of curvature degree and hematocrit level on cellular blood flow in a curved micro-vessel with a saccular aneurysm. Accordingly, a three-dimensional numerical simulation is performed using a validated code developed for cellular blood flow problems. The obtained results show that the cell-free layer thickness is highly dependent on the curvature degree and hematocrit level, which may have a remarkable impact on the apparent viscosity of blood as well as the dynamics of other particles such as drug particulates. The near-wall region exhibits the highest degree of cell deformation, whereas the red blood cells within the aneurysm zone remain nearly undeformed. Meanwhile, the velocity of the red blood cells decreases with the increase in curvature degree, which can affect the quality of the oxygenation process. Because of the saccular aneurysm, a considerable decrease in plasma velocity is predicted. Moreover, no secondary flows are detected in the curved vessel except in the aneurysm zone. An increase in the curvature degree is expected to reduce the blood flow rate by about 10%. Furthermore, low wall shear stress values are predicted in the straight case compared to the values at the apex of the curved vessel, which may affect the structure and function of the endothelial cells of the vessel wall and, hence, increase the aneurysm rupture possibility.
期刊介绍:
Biomicrofluidics (BMF) is an online-only journal published by AIP Publishing to rapidly disseminate research in fundamental physicochemical mechanisms associated with microfluidic and nanofluidic phenomena. BMF also publishes research in unique microfluidic and nanofluidic techniques for diagnostic, medical, biological, pharmaceutical, environmental, and chemical applications.
BMF offers quick publication, multimedia capability, and worldwide circulation among academic, national, and industrial laboratories. With a primary focus on high-quality original research articles, BMF also organizes special sections that help explain and define specific challenges unique to the interdisciplinary field of biomicrofluidics.
Microfluidic and nanofluidic actuation (electrokinetics, acoustofluidics, optofluidics, capillary)
Liquid Biopsy (microRNA profiling, circulating tumor cell isolation, exosome isolation, circulating tumor DNA quantification)
Cell sorting, manipulation, and transfection (di/electrophoresis, magnetic beads, optical traps, electroporation)
Molecular Separation and Concentration (isotachophoresis, concentration polarization, di/electrophoresis, magnetic beads, nanoparticles)
Cell culture and analysis(single cell assays, stimuli response, stem cell transfection)
Genomic and proteomic analysis (rapid gene sequencing, DNA/protein/carbohydrate arrays)
Biosensors (immuno-assay, nucleic acid fluorescent assay, colorimetric assay, enzyme amplification, plasmonic and Raman nano-reporter, molecular beacon, FRET, aptamer, nanopore, optical fibers)
Biophysical transport and characterization (DNA, single protein, ion channel and membrane dynamics, cell motility and communication mechanisms, electrophysiology, patch clamping). Etc...