利用国家稳定性协议框架,评估用于门诊非肠道抗菌治疗的弹性输注装置中头孢他啶/阿维菌素的稳定性。

IF 3.7 Q2 INFECTIOUS DISEASES JAC-Antimicrobial Resistance Pub Date : 2024-04-05 eCollection Date: 2024-04-01 DOI:10.1093/jacamr/dlae056
Saiyuri Naicker, Jason A Roberts, Hayoung Won, Steven C Wallis, Sean Unwin, Conor Jamieson, Tim Hills, Mark Gilchrist, Mark Santillo, R Andrew Seaton, Felicity Drummond, Fekade B Sime
{"title":"利用国家稳定性协议框架,评估用于门诊非肠道抗菌治疗的弹性输注装置中头孢他啶/阿维菌素的稳定性。","authors":"Saiyuri Naicker, Jason A Roberts, Hayoung Won, Steven C Wallis, Sean Unwin, Conor Jamieson, Tim Hills, Mark Gilchrist, Mark Santillo, R Andrew Seaton, Felicity Drummond, Fekade B Sime","doi":"10.1093/jacamr/dlae056","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the stability of ceftazidime/avibactam in elastomeric infusers, utilizing the UK's Yellow Cover Document (YCD) stability testing framework, in conditions representative of OPAT practice.</p><p><strong>Methods: </strong>Ceftazidime/avibactam was reconstituted with sodium chloride 0.9% (w/v) in two elastomeric infusers at concentrations (dose) levels of 1500/375, 3000/750 and 6000 mg/1500 mg in 240 mL. The infusers were exposed to a fridge storage (2°C-8°C) for 14 days followed by 24 h in-use temperature (32°C).</p><p><strong>Results: </strong>After 14 days of fridge storage and subsequent 24 h exposure to 32°C, mean ± SD of ceftazidime percent remaining was 75.5% ± 1.8%, 79.9% ± 1.1%, 82.4% ± 0.6%, for Easypump, and 81.7% ± 1.2%, 82.5% ± 0.5%, 85.4% ± 1.1% for Dosi-Fuser devices at the high, intermediate and low doses tested, respectively. For avibactam, mean ± SD percent remaining was 83.2% ± 1.8%, 87.4% ± 2.0%, 93.1% ± 0.9% for Easypump, and 85.1% ± 2.0%, 86.7% ± 0.1%, 92.5% ± 0.1% for Dosi-Fuser devices. The cumulative amount of pyridine generated in the devices ranged from 10.4 mg at low dose to 76.9 mg at high dose. Regression-based simulation showed that the degradation of both ceftazidime and avibactam was <10% for at least 12 h of the running phase, if stored in a fridge for not more than 72 h prior to in-use temperature exposure.</p><p><strong>Conclusions: </strong>Whilst not meeting the strict UK YCD criteria for ≤5% degradation, ceftazidime/avibactam may be acceptable to administer as a continuous 12 hourly infusion in those territories where degradation of ≤10% is deemed acceptable.</p>","PeriodicalId":14594,"journal":{"name":"JAC-Antimicrobial Resistance","volume":"6 2","pages":"dlae056"},"PeriodicalIF":3.7000,"publicationDate":"2024-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10995722/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the stability of ceftazidime/avibactam in elastomeric infusion devices used for outpatient parenteral antimicrobial therapy utilizing a national stability protocol framework.\",\"authors\":\"Saiyuri Naicker, Jason A Roberts, Hayoung Won, Steven C Wallis, Sean Unwin, Conor Jamieson, Tim Hills, Mark Gilchrist, Mark Santillo, R Andrew Seaton, Felicity Drummond, Fekade B Sime\",\"doi\":\"10.1093/jacamr/dlae056\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To evaluate the stability of ceftazidime/avibactam in elastomeric infusers, utilizing the UK's Yellow Cover Document (YCD) stability testing framework, in conditions representative of OPAT practice.</p><p><strong>Methods: </strong>Ceftazidime/avibactam was reconstituted with sodium chloride 0.9% (w/v) in two elastomeric infusers at concentrations (dose) levels of 1500/375, 3000/750 and 6000 mg/1500 mg in 240 mL. The infusers were exposed to a fridge storage (2°C-8°C) for 14 days followed by 24 h in-use temperature (32°C).</p><p><strong>Results: </strong>After 14 days of fridge storage and subsequent 24 h exposure to 32°C, mean ± SD of ceftazidime percent remaining was 75.5% ± 1.8%, 79.9% ± 1.1%, 82.4% ± 0.6%, for Easypump, and 81.7% ± 1.2%, 82.5% ± 0.5%, 85.4% ± 1.1% for Dosi-Fuser devices at the high, intermediate and low doses tested, respectively. For avibactam, mean ± SD percent remaining was 83.2% ± 1.8%, 87.4% ± 2.0%, 93.1% ± 0.9% for Easypump, and 85.1% ± 2.0%, 86.7% ± 0.1%, 92.5% ± 0.1% for Dosi-Fuser devices. The cumulative amount of pyridine generated in the devices ranged from 10.4 mg at low dose to 76.9 mg at high dose. Regression-based simulation showed that the degradation of both ceftazidime and avibactam was <10% for at least 12 h of the running phase, if stored in a fridge for not more than 72 h prior to in-use temperature exposure.</p><p><strong>Conclusions: </strong>Whilst not meeting the strict UK YCD criteria for ≤5% degradation, ceftazidime/avibactam may be acceptable to administer as a continuous 12 hourly infusion in those territories where degradation of ≤10% is deemed acceptable.</p>\",\"PeriodicalId\":14594,\"journal\":{\"name\":\"JAC-Antimicrobial Resistance\",\"volume\":\"6 2\",\"pages\":\"dlae056\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2024-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10995722/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JAC-Antimicrobial Resistance\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/jacamr/dlae056\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/4/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"INFECTIOUS DISEASES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JAC-Antimicrobial Resistance","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jacamr/dlae056","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

摘要

目的利用英国黄皮书(YCD)稳定性测试框架,评估头孢他啶/阿维巴坦在弹性输液器中的稳定性:用 0.9% 氯化钠(w/v)将头孢唑肟/阿维菌素重新配制在两个弹性输液器中,浓度(剂量)分别为 1500/375、3000/750 和 6000 毫克/1500 毫克(240 毫升)。输液器在冰箱中(2°C-8°C)存放 14 天,然后在使用温度(32°C)下存放 24 小时:结果:经过 14 天的冰箱储存和随后 24 小时 32°C 的暴露后,Easypump 和 Dosi-Fuser 设备在高、中、低剂量测试中的头孢他啶剩余率平均值(± SD)分别为 75.5% ± 1.8%、79.9% ± 1.1%、82.4% ± 0.6%;Dosi-Fuser 设备的剩余率平均值(± SD)分别为 81.7% ± 1.2%、82.5% ± 0.5%、85.4% ± 1.1%。对于阿维菌素,Easypump 的平均剩余率(± SD)分别为 83.2% ± 1.8%、87.4% ± 2.0%、93.1% ± 0.9%,Dosi-Fuser 装置的平均剩余率(± SD)分别为 85.1% ± 2.0%、86.7% ± 0.1%、92.5% ± 0.1%。装置中产生的吡啶累积量从低剂量的 10.4 毫克到高剂量的 76.9 毫克不等。基于回归的模拟显示,头孢他啶和阿维菌素的降解均为结论:头孢他啶/阿维巴坦虽然不符合英国 YCD 关于降解率≤5%的严格标准,但在降解率≤10%可接受的地区,头孢他啶/阿维巴坦作为 12 小时连续输注用药是可以接受的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of the stability of ceftazidime/avibactam in elastomeric infusion devices used for outpatient parenteral antimicrobial therapy utilizing a national stability protocol framework.

Objectives: To evaluate the stability of ceftazidime/avibactam in elastomeric infusers, utilizing the UK's Yellow Cover Document (YCD) stability testing framework, in conditions representative of OPAT practice.

Methods: Ceftazidime/avibactam was reconstituted with sodium chloride 0.9% (w/v) in two elastomeric infusers at concentrations (dose) levels of 1500/375, 3000/750 and 6000 mg/1500 mg in 240 mL. The infusers were exposed to a fridge storage (2°C-8°C) for 14 days followed by 24 h in-use temperature (32°C).

Results: After 14 days of fridge storage and subsequent 24 h exposure to 32°C, mean ± SD of ceftazidime percent remaining was 75.5% ± 1.8%, 79.9% ± 1.1%, 82.4% ± 0.6%, for Easypump, and 81.7% ± 1.2%, 82.5% ± 0.5%, 85.4% ± 1.1% for Dosi-Fuser devices at the high, intermediate and low doses tested, respectively. For avibactam, mean ± SD percent remaining was 83.2% ± 1.8%, 87.4% ± 2.0%, 93.1% ± 0.9% for Easypump, and 85.1% ± 2.0%, 86.7% ± 0.1%, 92.5% ± 0.1% for Dosi-Fuser devices. The cumulative amount of pyridine generated in the devices ranged from 10.4 mg at low dose to 76.9 mg at high dose. Regression-based simulation showed that the degradation of both ceftazidime and avibactam was <10% for at least 12 h of the running phase, if stored in a fridge for not more than 72 h prior to in-use temperature exposure.

Conclusions: Whilst not meeting the strict UK YCD criteria for ≤5% degradation, ceftazidime/avibactam may be acceptable to administer as a continuous 12 hourly infusion in those territories where degradation of ≤10% is deemed acceptable.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.30
自引率
0.00%
发文量
0
审稿时长
16 weeks
期刊最新文献
Investigation of cefiderocol resistance prevalence and resistance mechanisms in carbapenem-resistant Pseudomonas aeruginosa, Germany 2019-21. Medical school ranking and provider outpatient Medicare Part D claims for antibiotics among older patients in the USA. Nursing home nurses' opinion profiles on the potential evolution of their role in antimicrobial stewardship and associated factors: a national cross-sectional study in France. Clinical pharmacist-led antifungal drug utilization reviews in cancer care hospital: a prospective audit and feedback. State of the art of real-life concentration monitoring of rifampicin and its implementation contextualized in resource-limited settings: the Tanzanian case.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1