降低工厂能耗,提供升级版能源系统,提高能源绩效

Armin Tayefeh, Alireza Aslani, Rahim Zahedi, Hossein Yousefi
{"title":"降低工厂能耗,提供升级版能源系统,提高能源绩效","authors":"Armin Tayefeh,&nbsp;Alireza Aslani,&nbsp;Rahim Zahedi,&nbsp;Hossein Yousefi","doi":"10.1016/j.cles.2024.100124","DOIUrl":null,"url":null,"abstract":"<div><p>The industrial sector is a major energy consumer worldwide. Much of this consumption is due to air conditioning systems. In regions with extreme temperature conditions, the electricity consumption of these air conditioning systems increases significantly. This study was carried out with the objective of calculating the total energy consumption of the factory and identifying methods to decrease it. Furthermore, an enhanced energy system is suggested to lower energy consumption. This study was carried out with the objective of calculating the total energy consumption of the factory and identifying methods to decrease it. Furthermore, an enhanced energy system is suggested to lower energy consumption. It is also evident that the cooling load decreases by 21,661 kWh when thermal insulation is applied to the walls. Utilizing double-glazed windows for the skylight roof can lead to a reduction in the cooling load by 822 kWh. Additionally, the use of Light-Emitting Diode (LED) bulb lamps in the factory can further decrease the cooling load by up to 14,717 kWh.</p></div>","PeriodicalId":100252,"journal":{"name":"Cleaner Energy Systems","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2772783124000189/pdfft?md5=d3eb238ce55f4bf09490f5f561fe5213&pid=1-s2.0-S2772783124000189-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Reducing energy consumption in a factory and providing an upgraded energy system to improve energy performance\",\"authors\":\"Armin Tayefeh,&nbsp;Alireza Aslani,&nbsp;Rahim Zahedi,&nbsp;Hossein Yousefi\",\"doi\":\"10.1016/j.cles.2024.100124\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The industrial sector is a major energy consumer worldwide. Much of this consumption is due to air conditioning systems. In regions with extreme temperature conditions, the electricity consumption of these air conditioning systems increases significantly. This study was carried out with the objective of calculating the total energy consumption of the factory and identifying methods to decrease it. Furthermore, an enhanced energy system is suggested to lower energy consumption. This study was carried out with the objective of calculating the total energy consumption of the factory and identifying methods to decrease it. Furthermore, an enhanced energy system is suggested to lower energy consumption. It is also evident that the cooling load decreases by 21,661 kWh when thermal insulation is applied to the walls. Utilizing double-glazed windows for the skylight roof can lead to a reduction in the cooling load by 822 kWh. Additionally, the use of Light-Emitting Diode (LED) bulb lamps in the factory can further decrease the cooling load by up to 14,717 kWh.</p></div>\",\"PeriodicalId\":100252,\"journal\":{\"name\":\"Cleaner Energy Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2772783124000189/pdfft?md5=d3eb238ce55f4bf09490f5f561fe5213&pid=1-s2.0-S2772783124000189-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cleaner Energy Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2772783124000189\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cleaner Energy Systems","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772783124000189","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

工业部门是全球能源消耗大户。大部分能源消耗来自空调系统。在温度条件极端恶劣的地区,这些空调系统的耗电量会大幅增加。本研究旨在计算工厂的总能耗,并找出降低能耗的方法。此外,还建议采用增强型能源系统来降低能耗。本研究旨在计算工厂的总能耗,并确定降低能耗的方法。此外,还建议采用增强型能源系统来降低能耗。同样明显的是,在墙壁上使用隔热材料后,冷却负荷减少了 21 661 千瓦时。屋顶天窗采用双层玻璃窗可减少 822 千瓦时的制冷负荷。此外,在工厂中使用发光二极管 (LED) 灯泡可进一步减少制冷负荷,最多可减少 14,717 千瓦时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reducing energy consumption in a factory and providing an upgraded energy system to improve energy performance

The industrial sector is a major energy consumer worldwide. Much of this consumption is due to air conditioning systems. In regions with extreme temperature conditions, the electricity consumption of these air conditioning systems increases significantly. This study was carried out with the objective of calculating the total energy consumption of the factory and identifying methods to decrease it. Furthermore, an enhanced energy system is suggested to lower energy consumption. This study was carried out with the objective of calculating the total energy consumption of the factory and identifying methods to decrease it. Furthermore, an enhanced energy system is suggested to lower energy consumption. It is also evident that the cooling load decreases by 21,661 kWh when thermal insulation is applied to the walls. Utilizing double-glazed windows for the skylight roof can lead to a reduction in the cooling load by 822 kWh. Additionally, the use of Light-Emitting Diode (LED) bulb lamps in the factory can further decrease the cooling load by up to 14,717 kWh.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.00
自引率
0.00%
发文量
0
期刊最新文献
Simulation of a system to simultaneously recover CO2 and sweet carbon-neutral natural gas from wet natural gas: A delve into process inputs and units performances Optimizing a hybrid wind-solar-biomass system with battery and hydrogen storage using generic algorithm-particle swarm optimization for performance assessment Design and implementation of a control system for multifunctional applications of a Battery Energy Storage System (BESS) in a power system network Optimizing textile dyeing and finishing for improved energy efficiency and sustainability in fleece knitted fabrics Techno economic study of floating solar photovoltaic project in Indonesia using RETscreen
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1