Weidong Zhang, Yu Cui, Li Liu, Wenquan Wang, Wenzheng Chen, Rui Li, Fuhui Wang
{"title":"在 600 °C 湿氧气流中沉积固体氯化钠的预氧化 GH4169 合金的腐蚀行为","authors":"Weidong Zhang, Yu Cui, Li Liu, Wenquan Wang, Wenzheng Chen, Rui Li, Fuhui Wang","doi":"10.1007/s40195-024-01699-9","DOIUrl":null,"url":null,"abstract":"<div><p>The corrosion behavior of the pre-oxidized GH4169 alloy was studied after 20 h of exposure under a solid NaCl deposit film in a wet O<sub>2</sub> environment at 600 °C by mass-gain measurements, X-ray diffraction, scanning electron microscopy, transmission electron microscopy methods. The results indicate that the pre-oxidized GH4169 alloy undergoes serious corrosion in the corrosive condition. The preformed Cr<sub>2</sub>O<sub>3</sub> layer is gradually destroyed by deposit NaCl, and the inner Nb<sub>2</sub>O<sub>5</sub> layer beneath the complete outer Cr<sub>2</sub>O<sub>3</sub> layer also reacts with NaCl to form NaNbO<sub>3</sub>. The electrochemical test results testified the existence of electrochemical reactions during this corrosion process. The corrosion behavior of pre-oxidized GH4169 under a solid NaCl deposit film in a wet O<sub>2</sub> environment at 600 °C has been discussed in detail.</p></div>","PeriodicalId":457,"journal":{"name":"Acta Metallurgica Sinica-English Letters","volume":"37 7","pages":"1249 - 1264"},"PeriodicalIF":2.9000,"publicationDate":"2024-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Corrosion Behavior of Pre-oxidized GH4169 Alloy with Solid NaCl Deposited in a Wet Oxygen Flow at 600 °C\",\"authors\":\"Weidong Zhang, Yu Cui, Li Liu, Wenquan Wang, Wenzheng Chen, Rui Li, Fuhui Wang\",\"doi\":\"10.1007/s40195-024-01699-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The corrosion behavior of the pre-oxidized GH4169 alloy was studied after 20 h of exposure under a solid NaCl deposit film in a wet O<sub>2</sub> environment at 600 °C by mass-gain measurements, X-ray diffraction, scanning electron microscopy, transmission electron microscopy methods. The results indicate that the pre-oxidized GH4169 alloy undergoes serious corrosion in the corrosive condition. The preformed Cr<sub>2</sub>O<sub>3</sub> layer is gradually destroyed by deposit NaCl, and the inner Nb<sub>2</sub>O<sub>5</sub> layer beneath the complete outer Cr<sub>2</sub>O<sub>3</sub> layer also reacts with NaCl to form NaNbO<sub>3</sub>. The electrochemical test results testified the existence of electrochemical reactions during this corrosion process. The corrosion behavior of pre-oxidized GH4169 under a solid NaCl deposit film in a wet O<sub>2</sub> environment at 600 °C has been discussed in detail.</p></div>\",\"PeriodicalId\":457,\"journal\":{\"name\":\"Acta Metallurgica Sinica-English Letters\",\"volume\":\"37 7\",\"pages\":\"1249 - 1264\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-05-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Metallurgica Sinica-English Letters\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s40195-024-01699-9\",\"RegionNum\":2,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"METALLURGY & METALLURGICAL ENGINEERING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Metallurgica Sinica-English Letters","FirstCategoryId":"1","ListUrlMain":"https://link.springer.com/article/10.1007/s40195-024-01699-9","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"METALLURGY & METALLURGICAL ENGINEERING","Score":null,"Total":0}
Corrosion Behavior of Pre-oxidized GH4169 Alloy with Solid NaCl Deposited in a Wet Oxygen Flow at 600 °C
The corrosion behavior of the pre-oxidized GH4169 alloy was studied after 20 h of exposure under a solid NaCl deposit film in a wet O2 environment at 600 °C by mass-gain measurements, X-ray diffraction, scanning electron microscopy, transmission electron microscopy methods. The results indicate that the pre-oxidized GH4169 alloy undergoes serious corrosion in the corrosive condition. The preformed Cr2O3 layer is gradually destroyed by deposit NaCl, and the inner Nb2O5 layer beneath the complete outer Cr2O3 layer also reacts with NaCl to form NaNbO3. The electrochemical test results testified the existence of electrochemical reactions during this corrosion process. The corrosion behavior of pre-oxidized GH4169 under a solid NaCl deposit film in a wet O2 environment at 600 °C has been discussed in detail.
期刊介绍:
This international journal presents compact reports of significant, original and timely research reflecting progress in metallurgy, materials science and engineering, including materials physics, physical metallurgy, and process metallurgy.