提高光谱域光学相干断层扫描和光学相干断层血管造影监测近视黄斑新生血管活动的准确性。

IF 3.7 2区 医学 Q1 OPHTHALMOLOGY British Journal of Ophthalmology Pub Date : 2024-11-22 DOI:10.1136/bjo-2023-323374
Danny Siu-Chun Ng, Li Jia Chen, Leo Ka Yu Chan, Fang Yao Tang, Wee-Min Teh, Linbin Zhou, Fiona Chan, Eleanor Sui Sum Lin, Ka Wai Yuen, Wai Kit Chu, Shaheeda Mohamed, Chi Wai Tsang, Xinyuan Zhang, Jason C Yam, Chi-Pui Pang, Timothy Y Y Lai
{"title":"提高光谱域光学相干断层扫描和光学相干断层血管造影监测近视黄斑新生血管活动的准确性。","authors":"Danny Siu-Chun Ng, Li Jia Chen, Leo Ka Yu Chan, Fang Yao Tang, Wee-Min Teh, Linbin Zhou, Fiona Chan, Eleanor Sui Sum Lin, Ka Wai Yuen, Wai Kit Chu, Shaheeda Mohamed, Chi Wai Tsang, Xinyuan Zhang, Jason C Yam, Chi-Pui Pang, Timothy Y Y Lai","doi":"10.1136/bjo-2023-323374","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/aims: </strong>To evaluate the diagnostic accuracy of spectral-domain optical coherence tomography (SD OCT) combined with OCT angiography (OCTA) for myopic myopic macular neovascularisation (MNV) activity.</p><p><strong>Methods: </strong>Both eyes of patients with myopic MNV diagnosed with fluorescein angiography (FA), SD OCT and OCTA were assessed by unmasked investigators. The images were deidentified and randomised before graded by masked investigators, who determined the presence of active myopic MNV by using SD OCT together with OCTA without FA and by FA alone, respectively. The findings of masked investigators were compared with unmasked investigators.</p><p><strong>Results: </strong>213 eyes of 110 patients comprising 499 imaging episodes were eligible for grading. For diagnosing new-onset myopic MNV without FA, combined use of SD OCT and OCTA had a sensitivity of 0.94, specificity of 0.84 and area under the curve (AUC) of 0.92. FA had a sensitivity of 0.52 (p<0.01), specificity of 0.80 (p=0.38) and AUC of 0.66 (p<0.01). For recurrent myopic MNV, the combination of SD OCT and OCTA had a sensitivity of 0.98, specificity of 0.78 and AUC of 0.88. FA had a sensitivity of 0.50 (p=0.04), specificity of 0.76 (p=0.85) and AUC of 0.63 (p=0.01). Myopic traction maculopathy was more frequently associated with recurrent myopic MNV (p<0.01).</p><p><strong>Conclusion: </strong>SD OCT with dense volumetric scan was highly sensitive for diagnosing myopic MNV. The addition of OCTA improved the diagnostic specificity without FA. Monitoring of the longitudinal changes on SD OCT and judicious use of FA is a reliable surveillance strategy for myopic MNV.</p>","PeriodicalId":9313,"journal":{"name":"British Journal of Ophthalmology","volume":" ","pages":"1729-1736"},"PeriodicalIF":3.7000,"publicationDate":"2024-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improved accuracy of spectral-domain optical coherence tomography and optical coherence tomography angiography for monitoring myopic macular neovascularisation activity.\",\"authors\":\"Danny Siu-Chun Ng, Li Jia Chen, Leo Ka Yu Chan, Fang Yao Tang, Wee-Min Teh, Linbin Zhou, Fiona Chan, Eleanor Sui Sum Lin, Ka Wai Yuen, Wai Kit Chu, Shaheeda Mohamed, Chi Wai Tsang, Xinyuan Zhang, Jason C Yam, Chi-Pui Pang, Timothy Y Y Lai\",\"doi\":\"10.1136/bjo-2023-323374\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background/aims: </strong>To evaluate the diagnostic accuracy of spectral-domain optical coherence tomography (SD OCT) combined with OCT angiography (OCTA) for myopic myopic macular neovascularisation (MNV) activity.</p><p><strong>Methods: </strong>Both eyes of patients with myopic MNV diagnosed with fluorescein angiography (FA), SD OCT and OCTA were assessed by unmasked investigators. The images were deidentified and randomised before graded by masked investigators, who determined the presence of active myopic MNV by using SD OCT together with OCTA without FA and by FA alone, respectively. The findings of masked investigators were compared with unmasked investigators.</p><p><strong>Results: </strong>213 eyes of 110 patients comprising 499 imaging episodes were eligible for grading. For diagnosing new-onset myopic MNV without FA, combined use of SD OCT and OCTA had a sensitivity of 0.94, specificity of 0.84 and area under the curve (AUC) of 0.92. FA had a sensitivity of 0.52 (p<0.01), specificity of 0.80 (p=0.38) and AUC of 0.66 (p<0.01). For recurrent myopic MNV, the combination of SD OCT and OCTA had a sensitivity of 0.98, specificity of 0.78 and AUC of 0.88. FA had a sensitivity of 0.50 (p=0.04), specificity of 0.76 (p=0.85) and AUC of 0.63 (p=0.01). Myopic traction maculopathy was more frequently associated with recurrent myopic MNV (p<0.01).</p><p><strong>Conclusion: </strong>SD OCT with dense volumetric scan was highly sensitive for diagnosing myopic MNV. The addition of OCTA improved the diagnostic specificity without FA. Monitoring of the longitudinal changes on SD OCT and judicious use of FA is a reliable surveillance strategy for myopic MNV.</p>\",\"PeriodicalId\":9313,\"journal\":{\"name\":\"British Journal of Ophthalmology\",\"volume\":\" \",\"pages\":\"1729-1736\"},\"PeriodicalIF\":3.7000,\"publicationDate\":\"2024-11-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"British Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1136/bjo-2023-323374\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"British Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/bjo-2023-323374","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景/目的:评估光谱域光学相干断层扫描(SD OCT)结合OCT血管造影(OCTA)对近视眼黄斑新生血管(MNV)活动的诊断准确性:方法:由不戴眼罩的研究人员对通过荧光素血管造影(FA)、SD OCT 和 OCTA 诊断为近视性黄斑新生血管的患者的双眼进行评估。在由蒙面调查员进行分级之前,对图像进行了去身份化和随机化处理,蒙面调查员分别通过使用 SD OCT 和不含 FA 的 OCTA 以及仅使用 FA 来确定是否存在活动性近视 MNV。结果:110 名患者的 213 只眼睛共 499 次成像符合分级条件。在诊断无 FA 的新发近视 MNV 时,联合使用 SD OCT 和 OCTA 的灵敏度为 0.94,特异性为 0.84,曲线下面积(AUC)为 0.92。FA的灵敏度为0.52(p结论:带有致密容积扫描的 SD OCT 对近视 MNV 的诊断高度敏感。在没有 FA 的情况下,增加 OCTA 可提高诊断特异性。监测SD OCT的纵向变化并明智地使用FA是一种可靠的近视MNV监测策略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Improved accuracy of spectral-domain optical coherence tomography and optical coherence tomography angiography for monitoring myopic macular neovascularisation activity.

Background/aims: To evaluate the diagnostic accuracy of spectral-domain optical coherence tomography (SD OCT) combined with OCT angiography (OCTA) for myopic myopic macular neovascularisation (MNV) activity.

Methods: Both eyes of patients with myopic MNV diagnosed with fluorescein angiography (FA), SD OCT and OCTA were assessed by unmasked investigators. The images were deidentified and randomised before graded by masked investigators, who determined the presence of active myopic MNV by using SD OCT together with OCTA without FA and by FA alone, respectively. The findings of masked investigators were compared with unmasked investigators.

Results: 213 eyes of 110 patients comprising 499 imaging episodes were eligible for grading. For diagnosing new-onset myopic MNV without FA, combined use of SD OCT and OCTA had a sensitivity of 0.94, specificity of 0.84 and area under the curve (AUC) of 0.92. FA had a sensitivity of 0.52 (p<0.01), specificity of 0.80 (p=0.38) and AUC of 0.66 (p<0.01). For recurrent myopic MNV, the combination of SD OCT and OCTA had a sensitivity of 0.98, specificity of 0.78 and AUC of 0.88. FA had a sensitivity of 0.50 (p=0.04), specificity of 0.76 (p=0.85) and AUC of 0.63 (p=0.01). Myopic traction maculopathy was more frequently associated with recurrent myopic MNV (p<0.01).

Conclusion: SD OCT with dense volumetric scan was highly sensitive for diagnosing myopic MNV. The addition of OCTA improved the diagnostic specificity without FA. Monitoring of the longitudinal changes on SD OCT and judicious use of FA is a reliable surveillance strategy for myopic MNV.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
10.30
自引率
2.40%
发文量
213
审稿时长
3-6 weeks
期刊介绍: The British Journal of Ophthalmology (BJO) is an international peer-reviewed journal for ophthalmologists and visual science specialists. BJO publishes clinical investigations, clinical observations, and clinically relevant laboratory investigations related to ophthalmology. It also provides major reviews and also publishes manuscripts covering regional issues in a global context.
期刊最新文献
Associations between serum lipids and glaucoma: a cohort study of 400 229 UK Biobank participants. High-sensitivity C-reactive protein and risk of retinal artery occlusion and ischaemic stroke: a cross-cohort study. Evaluating lipid-lowering drug targets for full-course diabetic retinopathy. At a glance Risk factors for rapid axial length growth in a prospective cohort study of 3-year to 9-year-old Chinese children.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1