在消融术后恢复窦性心律的心房颤动患者中,博格体力消耗量表与通气无氧阈值不一致。

IF 16.4 1区 化学 Q1 CHEMISTRY, MULTIDISCIPLINARY Accounts of Chemical Research Pub Date : 2024-04-26 eCollection Date: 2024-04-01 DOI:10.12965/jer.2448056.028
Saori Nishimura, Ryou Tanaka, Shigeshi Kamikawa, Isao Waki, Daiki Yamashita, Natsumi Tabita, Shunichi Higashiya, Hirosuke Yamaji, Takashi Murakami, Shozo Kusachi
{"title":"在消融术后恢复窦性心律的心房颤动患者中,博格体力消耗量表与通气无氧阈值不一致。","authors":"Saori Nishimura, Ryou Tanaka, Shigeshi Kamikawa, Isao Waki, Daiki Yamashita, Natsumi Tabita, Shunichi Higashiya, Hirosuke Yamaji, Takashi Murakami, Shozo Kusachi","doi":"10.12965/jer.2448056.028","DOIUrl":null,"url":null,"abstract":"<p><p>The determination of precise exercise intensity is essential for effective exercise rehabilitation. The Borg rating of perceived exertion category ratio (CR) scale is utilized to prescribe an appropriate level of exertion intensity. A Borg CR of approximately 13 coincides with the ventilatory aerobic threshold (VAT). Patients with atrial fibrillation (AF) exhibit various symptoms. We hypothesized that the workload at Borg CR13 (Borg CR13-Watt) differs from the workload at the VAT level (VAT-Watt) in AF patients with restored sinus rhythm (SR) following ablation. Accordingly, the relationship between Borg CR13-Watt and VAT-Watt was studied in patients with restored SR. Cardiopulmonary exercise testing (CPET) was performed at 101±88 days after ablation in 150 patients using a bicycle ergometer. No adverse events were observed during CPET. Borg CR13-Watt was significantly higher than VAT-Watt (67.2±27.8 Watt vs. 54.7±17.6 Watt, <i>P</i><0.0001). Borg CR13-Watt showed significant linear regression with VAT-Watt (regression coefficient, 0.49, <i>P</i><0.01; correlation coefficient, 0.80, <i>P</i><0.01). Higher Borg CR13-Watt was associated with greater differences between Borg CR13-Watt and VAT-Watt (ΔWatt). The Bland-Altman plot showed nonconcordance between the two. Male sex, use of antiarrhythmic drugs, and smoking had contributed to the increased ΔWatt. Duration from ablation to time of CPET did not correlate with ΔWatt. Therefore, Borg CR13-Watt did not coincide with VAT-Watt in patients with restored SR. Higher Borg CR13-Watt was associated with greater ΔWatt. Prescribing exertion intensity as determined solely by perceived exertion is inadequate. CPET is required to determine the precise exercise intensity in AF patients with restored SR after ablation.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11079550/pdf/","citationCount":"0","resultStr":"{\"title\":\"Borg's exertion scale did not coincide with ventilatory anaerobic threshold in atrial fibrillation patients with restored sinus rhythm after ablation.\",\"authors\":\"Saori Nishimura, Ryou Tanaka, Shigeshi Kamikawa, Isao Waki, Daiki Yamashita, Natsumi Tabita, Shunichi Higashiya, Hirosuke Yamaji, Takashi Murakami, Shozo Kusachi\",\"doi\":\"10.12965/jer.2448056.028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The determination of precise exercise intensity is essential for effective exercise rehabilitation. The Borg rating of perceived exertion category ratio (CR) scale is utilized to prescribe an appropriate level of exertion intensity. A Borg CR of approximately 13 coincides with the ventilatory aerobic threshold (VAT). Patients with atrial fibrillation (AF) exhibit various symptoms. We hypothesized that the workload at Borg CR13 (Borg CR13-Watt) differs from the workload at the VAT level (VAT-Watt) in AF patients with restored sinus rhythm (SR) following ablation. Accordingly, the relationship between Borg CR13-Watt and VAT-Watt was studied in patients with restored SR. Cardiopulmonary exercise testing (CPET) was performed at 101±88 days after ablation in 150 patients using a bicycle ergometer. No adverse events were observed during CPET. Borg CR13-Watt was significantly higher than VAT-Watt (67.2±27.8 Watt vs. 54.7±17.6 Watt, <i>P</i><0.0001). Borg CR13-Watt showed significant linear regression with VAT-Watt (regression coefficient, 0.49, <i>P</i><0.01; correlation coefficient, 0.80, <i>P</i><0.01). Higher Borg CR13-Watt was associated with greater differences between Borg CR13-Watt and VAT-Watt (ΔWatt). The Bland-Altman plot showed nonconcordance between the two. Male sex, use of antiarrhythmic drugs, and smoking had contributed to the increased ΔWatt. Duration from ablation to time of CPET did not correlate with ΔWatt. Therefore, Borg CR13-Watt did not coincide with VAT-Watt in patients with restored SR. Higher Borg CR13-Watt was associated with greater ΔWatt. Prescribing exertion intensity as determined solely by perceived exertion is inadequate. CPET is required to determine the precise exercise intensity in AF patients with restored SR after ablation.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-04-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11079550/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12965/jer.2448056.028\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/4/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12965/jer.2448056.028","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

确定精确的运动强度对有效的运动康复至关重要。博格感知运动强度等级比(CR)表可用于规定适当的运动强度水平。博格CR约为13,与通气有氧阈值(VAT)相吻合。心房颤动(房颤)患者会表现出各种症状。我们假设,在消融术后恢复窦性心律(SR)的房颤患者中,Borg CR13 的工作量(Borg CR13-瓦特)不同于 VAT 水平的工作量(VAT-瓦特)。因此,我们对窦性心律恢复患者的 Borg CR13-Watt 和 VAT-Watt 之间的关系进行了研究。在消融术后 101±88 天,使用自行车测力计对 150 名患者进行了心肺运动测试(CPET)。CPET 期间未观察到不良事件。Borg CR13 瓦特明显高于 VAT 瓦特(67.2±27.8 瓦特 vs. 54.7±17.6 瓦特,PPP
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Borg's exertion scale did not coincide with ventilatory anaerobic threshold in atrial fibrillation patients with restored sinus rhythm after ablation.

The determination of precise exercise intensity is essential for effective exercise rehabilitation. The Borg rating of perceived exertion category ratio (CR) scale is utilized to prescribe an appropriate level of exertion intensity. A Borg CR of approximately 13 coincides with the ventilatory aerobic threshold (VAT). Patients with atrial fibrillation (AF) exhibit various symptoms. We hypothesized that the workload at Borg CR13 (Borg CR13-Watt) differs from the workload at the VAT level (VAT-Watt) in AF patients with restored sinus rhythm (SR) following ablation. Accordingly, the relationship between Borg CR13-Watt and VAT-Watt was studied in patients with restored SR. Cardiopulmonary exercise testing (CPET) was performed at 101±88 days after ablation in 150 patients using a bicycle ergometer. No adverse events were observed during CPET. Borg CR13-Watt was significantly higher than VAT-Watt (67.2±27.8 Watt vs. 54.7±17.6 Watt, P<0.0001). Borg CR13-Watt showed significant linear regression with VAT-Watt (regression coefficient, 0.49, P<0.01; correlation coefficient, 0.80, P<0.01). Higher Borg CR13-Watt was associated with greater differences between Borg CR13-Watt and VAT-Watt (ΔWatt). The Bland-Altman plot showed nonconcordance between the two. Male sex, use of antiarrhythmic drugs, and smoking had contributed to the increased ΔWatt. Duration from ablation to time of CPET did not correlate with ΔWatt. Therefore, Borg CR13-Watt did not coincide with VAT-Watt in patients with restored SR. Higher Borg CR13-Watt was associated with greater ΔWatt. Prescribing exertion intensity as determined solely by perceived exertion is inadequate. CPET is required to determine the precise exercise intensity in AF patients with restored SR after ablation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
期刊最新文献
Intentions to move abroad among medical students: a cross-sectional study to investigate determinants and opinions. Analysis of Medical Rehabilitation Needs of 2023 Kahramanmaraş Earthquake Victims: Adıyaman Example. Efficacy of whole body vibration on fascicle length and joint angle in children with hemiplegic cerebral palsy. The change process questionnaire (CPQ): A psychometric validation. Prevalence and predictors of hand hygiene compliance in clinical, surgical and intensive care unit wards: results of a second cross-sectional study at the Umberto I teaching hospital of Rome.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1