{"title":"在消融术后恢复窦性心律的心房颤动患者中,博格体力消耗量表与通气无氧阈值不一致。","authors":"Saori Nishimura, Ryou Tanaka, Shigeshi Kamikawa, Isao Waki, Daiki Yamashita, Natsumi Tabita, Shunichi Higashiya, Hirosuke Yamaji, Takashi Murakami, Shozo Kusachi","doi":"10.12965/jer.2448056.028","DOIUrl":null,"url":null,"abstract":"<p><p>The determination of precise exercise intensity is essential for effective exercise rehabilitation. The Borg rating of perceived exertion category ratio (CR) scale is utilized to prescribe an appropriate level of exertion intensity. A Borg CR of approximately 13 coincides with the ventilatory aerobic threshold (VAT). Patients with atrial fibrillation (AF) exhibit various symptoms. We hypothesized that the workload at Borg CR13 (Borg CR13-Watt) differs from the workload at the VAT level (VAT-Watt) in AF patients with restored sinus rhythm (SR) following ablation. Accordingly, the relationship between Borg CR13-Watt and VAT-Watt was studied in patients with restored SR. Cardiopulmonary exercise testing (CPET) was performed at 101±88 days after ablation in 150 patients using a bicycle ergometer. No adverse events were observed during CPET. Borg CR13-Watt was significantly higher than VAT-Watt (67.2±27.8 Watt vs. 54.7±17.6 Watt, <i>P</i><0.0001). Borg CR13-Watt showed significant linear regression with VAT-Watt (regression coefficient, 0.49, <i>P</i><0.01; correlation coefficient, 0.80, <i>P</i><0.01). Higher Borg CR13-Watt was associated with greater differences between Borg CR13-Watt and VAT-Watt (ΔWatt). The Bland-Altman plot showed nonconcordance between the two. Male sex, use of antiarrhythmic drugs, and smoking had contributed to the increased ΔWatt. Duration from ablation to time of CPET did not correlate with ΔWatt. Therefore, Borg CR13-Watt did not coincide with VAT-Watt in patients with restored SR. Higher Borg CR13-Watt was associated with greater ΔWatt. Prescribing exertion intensity as determined solely by perceived exertion is inadequate. CPET is required to determine the precise exercise intensity in AF patients with restored SR after ablation.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11079550/pdf/","citationCount":"0","resultStr":"{\"title\":\"Borg's exertion scale did not coincide with ventilatory anaerobic threshold in atrial fibrillation patients with restored sinus rhythm after ablation.\",\"authors\":\"Saori Nishimura, Ryou Tanaka, Shigeshi Kamikawa, Isao Waki, Daiki Yamashita, Natsumi Tabita, Shunichi Higashiya, Hirosuke Yamaji, Takashi Murakami, Shozo Kusachi\",\"doi\":\"10.12965/jer.2448056.028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The determination of precise exercise intensity is essential for effective exercise rehabilitation. The Borg rating of perceived exertion category ratio (CR) scale is utilized to prescribe an appropriate level of exertion intensity. A Borg CR of approximately 13 coincides with the ventilatory aerobic threshold (VAT). Patients with atrial fibrillation (AF) exhibit various symptoms. We hypothesized that the workload at Borg CR13 (Borg CR13-Watt) differs from the workload at the VAT level (VAT-Watt) in AF patients with restored sinus rhythm (SR) following ablation. Accordingly, the relationship between Borg CR13-Watt and VAT-Watt was studied in patients with restored SR. Cardiopulmonary exercise testing (CPET) was performed at 101±88 days after ablation in 150 patients using a bicycle ergometer. No adverse events were observed during CPET. Borg CR13-Watt was significantly higher than VAT-Watt (67.2±27.8 Watt vs. 54.7±17.6 Watt, <i>P</i><0.0001). Borg CR13-Watt showed significant linear regression with VAT-Watt (regression coefficient, 0.49, <i>P</i><0.01; correlation coefficient, 0.80, <i>P</i><0.01). Higher Borg CR13-Watt was associated with greater differences between Borg CR13-Watt and VAT-Watt (ΔWatt). The Bland-Altman plot showed nonconcordance between the two. Male sex, use of antiarrhythmic drugs, and smoking had contributed to the increased ΔWatt. Duration from ablation to time of CPET did not correlate with ΔWatt. Therefore, Borg CR13-Watt did not coincide with VAT-Watt in patients with restored SR. Higher Borg CR13-Watt was associated with greater ΔWatt. Prescribing exertion intensity as determined solely by perceived exertion is inadequate. CPET is required to determine the precise exercise intensity in AF patients with restored SR after ablation.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-04-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11079550/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12965/jer.2448056.028\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/4/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12965/jer.2448056.028","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Borg's exertion scale did not coincide with ventilatory anaerobic threshold in atrial fibrillation patients with restored sinus rhythm after ablation.
The determination of precise exercise intensity is essential for effective exercise rehabilitation. The Borg rating of perceived exertion category ratio (CR) scale is utilized to prescribe an appropriate level of exertion intensity. A Borg CR of approximately 13 coincides with the ventilatory aerobic threshold (VAT). Patients with atrial fibrillation (AF) exhibit various symptoms. We hypothesized that the workload at Borg CR13 (Borg CR13-Watt) differs from the workload at the VAT level (VAT-Watt) in AF patients with restored sinus rhythm (SR) following ablation. Accordingly, the relationship between Borg CR13-Watt and VAT-Watt was studied in patients with restored SR. Cardiopulmonary exercise testing (CPET) was performed at 101±88 days after ablation in 150 patients using a bicycle ergometer. No adverse events were observed during CPET. Borg CR13-Watt was significantly higher than VAT-Watt (67.2±27.8 Watt vs. 54.7±17.6 Watt, P<0.0001). Borg CR13-Watt showed significant linear regression with VAT-Watt (regression coefficient, 0.49, P<0.01; correlation coefficient, 0.80, P<0.01). Higher Borg CR13-Watt was associated with greater differences between Borg CR13-Watt and VAT-Watt (ΔWatt). The Bland-Altman plot showed nonconcordance between the two. Male sex, use of antiarrhythmic drugs, and smoking had contributed to the increased ΔWatt. Duration from ablation to time of CPET did not correlate with ΔWatt. Therefore, Borg CR13-Watt did not coincide with VAT-Watt in patients with restored SR. Higher Borg CR13-Watt was associated with greater ΔWatt. Prescribing exertion intensity as determined solely by perceived exertion is inadequate. CPET is required to determine the precise exercise intensity in AF patients with restored SR after ablation.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.