种植体周围炎与上颌窦膜增厚:回顾性队列研究

IF 4.8 1区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Clinical Oral Implants Research Pub Date : 2024-05-15 DOI:10.1111/clr.14282
Ramón Pons, Maria Giralt-Hernando, José Nart, Beatriz de Tapia, Federico Hernández-Alfaro, Alberto Monje
{"title":"种植体周围炎与上颌窦膜增厚:回顾性队列研究","authors":"Ramón Pons,&nbsp;Maria Giralt-Hernando,&nbsp;José Nart,&nbsp;Beatriz de Tapia,&nbsp;Federico Hernández-Alfaro,&nbsp;Alberto Monje","doi":"10.1111/clr.14282","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objective</h3>\n \n <p>The objective of this study is to investigate the association of peri-implantitis (PI) and sinus membrane thickening and to assess the resolution of membrane thickening following intervention (implant removal or peri-implantitis treatment) aimed at arresting PI.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>Forty-five patients with 61 implants in the posterior maxillary region were retrospectively included in the study. Twenty-four patients were diagnosed with peri-implantitis (PI) and 21 had peri-implant health (PH). Cone-beam computed tomography (CBCT) scans were evaluated to assess maxillary sinus characteristics, including membrane thickening, sinus occupancy and ostium patency. The CBCT scans taken 6 months after intervention aimed at arresting disease (implant removal or treatment of PI) in the PI group were also appraised and compared to baseline scans.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>At baseline, all parameters evaluating membrane thickness disorders yielded significant differences between groups (<i>p</i> &lt; .001). Patients with posterior maxillary implants diagnosed with PI were 7× more likely to present membrane thickening compatible with pathology when compared to patients with healthy implants (OR = 7.14; <i>p</i> = .005). Furthermore, the likelihood was 6x greater in implants diagnosed with PI to exhibit moderate membrane thickening (OR = 6.75, <i>p</i> = .001). The patients receiving interventions aimed at arresting PI experienced significant enhancement in all radiographic parameters related to the sinus cavity at the 6-month follow-up (<i>p</i> &lt; .001), though these variations were similarly independent of whether treatment consisted of PI treatment or implant removal.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>Maxillary sinus membrane thickening and the permeability/obstruction of the ostium are frequently associated with the presence of PI in posterior implants. Interventions targeting disease resolution effectively reduce membrane thickness to levels compatible with maxillary sinus health.</p>\n </section>\n </div>","PeriodicalId":10455,"journal":{"name":"Clinical Oral Implants Research","volume":"35 7","pages":"757-770"},"PeriodicalIF":4.8000,"publicationDate":"2024-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/clr.14282","citationCount":"0","resultStr":"{\"title\":\"Peri-implantitis and maxillary sinus membrane thickening: A retrospective cohort study\",\"authors\":\"Ramón Pons,&nbsp;Maria Giralt-Hernando,&nbsp;José Nart,&nbsp;Beatriz de Tapia,&nbsp;Federico Hernández-Alfaro,&nbsp;Alberto Monje\",\"doi\":\"10.1111/clr.14282\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Objective</h3>\\n \\n <p>The objective of this study is to investigate the association of peri-implantitis (PI) and sinus membrane thickening and to assess the resolution of membrane thickening following intervention (implant removal or peri-implantitis treatment) aimed at arresting PI.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Materials and Methods</h3>\\n \\n <p>Forty-five patients with 61 implants in the posterior maxillary region were retrospectively included in the study. Twenty-four patients were diagnosed with peri-implantitis (PI) and 21 had peri-implant health (PH). Cone-beam computed tomography (CBCT) scans were evaluated to assess maxillary sinus characteristics, including membrane thickening, sinus occupancy and ostium patency. The CBCT scans taken 6 months after intervention aimed at arresting disease (implant removal or treatment of PI) in the PI group were also appraised and compared to baseline scans.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>At baseline, all parameters evaluating membrane thickness disorders yielded significant differences between groups (<i>p</i> &lt; .001). Patients with posterior maxillary implants diagnosed with PI were 7× more likely to present membrane thickening compatible with pathology when compared to patients with healthy implants (OR = 7.14; <i>p</i> = .005). Furthermore, the likelihood was 6x greater in implants diagnosed with PI to exhibit moderate membrane thickening (OR = 6.75, <i>p</i> = .001). The patients receiving interventions aimed at arresting PI experienced significant enhancement in all radiographic parameters related to the sinus cavity at the 6-month follow-up (<i>p</i> &lt; .001), though these variations were similarly independent of whether treatment consisted of PI treatment or implant removal.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>Maxillary sinus membrane thickening and the permeability/obstruction of the ostium are frequently associated with the presence of PI in posterior implants. Interventions targeting disease resolution effectively reduce membrane thickness to levels compatible with maxillary sinus health.</p>\\n </section>\\n </div>\",\"PeriodicalId\":10455,\"journal\":{\"name\":\"Clinical Oral Implants Research\",\"volume\":\"35 7\",\"pages\":\"757-770\"},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2024-05-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1111/clr.14282\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Oral Implants Research\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/clr.14282\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Implants Research","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/clr.14282","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究的目的是调查种植体周围炎(PI)与窦膜增厚之间的关系,并评估旨在阻止 PI 的干预措施(拔除种植体或治疗种植体周围炎)后窦膜增厚的缓解情况:本研究回顾性地纳入了 45 名在上颌后部植入 61 个种植体的患者。24名患者被诊断为种植体周围炎(PI),21名患者为种植体周围健康(PH)。对锥形束计算机断层扫描(CBCT)进行了评估,以评估上颌窦的特征,包括窦膜增厚、窦占位和窦口通畅。此外,还评估了PI组患者在采取旨在遏制疾病的干预措施(拔除种植体或治疗PI)6个月后的CBCT扫描结果,并与基线扫描结果进行了比较:结果:基线扫描时,所有评估膜厚度紊乱的参数在各组之间均存在显著差异(P上颌窦膜增厚和骨膜的通透性/阻塞经常与后牙种植体中存在 PI 有关。以解决疾病为目标的干预措施能有效地将膜厚度降低到与上颌窦健康相适应的水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Peri-implantitis and maxillary sinus membrane thickening: A retrospective cohort study

Objective

The objective of this study is to investigate the association of peri-implantitis (PI) and sinus membrane thickening and to assess the resolution of membrane thickening following intervention (implant removal or peri-implantitis treatment) aimed at arresting PI.

Materials and Methods

Forty-five patients with 61 implants in the posterior maxillary region were retrospectively included in the study. Twenty-four patients were diagnosed with peri-implantitis (PI) and 21 had peri-implant health (PH). Cone-beam computed tomography (CBCT) scans were evaluated to assess maxillary sinus characteristics, including membrane thickening, sinus occupancy and ostium patency. The CBCT scans taken 6 months after intervention aimed at arresting disease (implant removal or treatment of PI) in the PI group were also appraised and compared to baseline scans.

Results

At baseline, all parameters evaluating membrane thickness disorders yielded significant differences between groups (p < .001). Patients with posterior maxillary implants diagnosed with PI were 7× more likely to present membrane thickening compatible with pathology when compared to patients with healthy implants (OR = 7.14; p = .005). Furthermore, the likelihood was 6x greater in implants diagnosed with PI to exhibit moderate membrane thickening (OR = 6.75, p = .001). The patients receiving interventions aimed at arresting PI experienced significant enhancement in all radiographic parameters related to the sinus cavity at the 6-month follow-up (p < .001), though these variations were similarly independent of whether treatment consisted of PI treatment or implant removal.

Conclusions

Maxillary sinus membrane thickening and the permeability/obstruction of the ostium are frequently associated with the presence of PI in posterior implants. Interventions targeting disease resolution effectively reduce membrane thickness to levels compatible with maxillary sinus health.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical Oral Implants Research
Clinical Oral Implants Research 医学-工程:生物医学
CiteScore
7.70
自引率
11.60%
发文量
149
审稿时长
3 months
期刊介绍: Clinical Oral Implants Research conveys scientific progress in the field of implant dentistry and its related areas to clinicians, teachers and researchers concerned with the application of this information for the benefit of patients in need of oral implants. The journal addresses itself to clinicians, general practitioners, periodontists, oral and maxillofacial surgeons and prosthodontists, as well as to teachers, academicians and scholars involved in the education of professionals and in the scientific promotion of the field of implant dentistry.
期刊最新文献
Fixed Full‐Arch Maxillary Prostheses Supported by Four Versus Six Implants: 5‐Year Results of a Multicenter Randomized Clinical Trial Prospective Clinical Study on the Accuracy of Static Computer-Assisted Implant Surgery in Patients With Distal Free-End Implants. Conventional Versus CAD-CAM Surgical Guides. Regeneration of Chronic Alveolar Vertical Defects Using a Micro Dosage of rhBMP-2. An Experimental In Vivo Study. Comparison Between Conventional and Artificial Intelligence-Assisted Setup for Digital Implant Planning: Accuracy, Time-Efficiency, and User Experience. Influence of Metal Artifact Reduction Tool of Two Cone Beam CT on the Detection of Bone Graft Loss Around Titanium and Zirconium Implants-An Ex Vivo Diagnostic Accuracy Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1