亚马逊鹦鹉(Amazona spp.)

IF 1.1 3区 农林科学 Q3 VETERINARY SCIENCES Journal of veterinary emergency and critical care Pub Date : 2024-05-18 DOI:10.1111/vec.13386
Amanda Burke DVM, Miryam Reems DVM, DACVECC, Maria Spriggs DVM, PhD
{"title":"亚马逊鹦鹉(Amazona spp.)","authors":"Amanda Burke DVM,&nbsp;Miryam Reems DVM, DACVECC,&nbsp;Maria Spriggs DVM, PhD","doi":"10.1111/vec.13386","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objective</h3>\n \n <p>To evaluate the feasibility of the point-of-care viscoelastic coagulation monitor (VCM) in Amazon parrots (<i>Amazona</i> spp.) and describe the parameters with fresh whole-blood samples in healthy Amazon parrots.</p>\n </section>\n \n <section>\n \n <h3> Design</h3>\n \n <p>A total of 18 Amazon parrots were enrolled. Physical examinations, a CBC, and a biochemistry profile, including bile acids, were performed on all parrots. VCM tracings were obtained at the time of venipuncture for baseline laboratory work.</p>\n </section>\n \n <section>\n \n <h3> Measurements and Main Results</h3>\n \n <p>The median clot time was 2102 seconds (range: 38.6–3599 s), median clot formation time was 929 seconds (range: 21.4–1711 s), median alpha angle was 20 (range: 6–67), and the median maximum clot formation was 8.5 (range: 0–36). The median lysis index at 30 minutes (LI30) was 100 (range: 98–100), and the median lysis index at 45 minutes (LI45) was 100 (range: 90–100). Of 18 samples, alpha angles were not reported in 7 samples, LI30 was not reported in 10 samples, and LI45 was not reported in 12 samples. Of the qualitative curves, 6 reflected normal mammalian curves, and the remainder were consistent with a hypocoaguable state.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The results were markedly variable, with the majority of VCM tracings being hypocoagulable in comparison with reference intervals established for dogs and cats. Using these protocols, the VCM is not reliable in Amazon parrots. Future areas of investigation include altering the temperature during sample analysis, the use of activators, or an exchange of clotting reagents for an extrinsic pathway activator, which may contribute to the success of this device in avian species.</p>\n </section>\n </div>","PeriodicalId":17603,"journal":{"name":"Journal of veterinary emergency and critical care","volume":"34 3","pages":"238-244"},"PeriodicalIF":1.1000,"publicationDate":"2024-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Point-of-care viscoelastic coagulation monitor parameters in Amazon parrots (Amazona spp.)\",\"authors\":\"Amanda Burke DVM,&nbsp;Miryam Reems DVM, DACVECC,&nbsp;Maria Spriggs DVM, PhD\",\"doi\":\"10.1111/vec.13386\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Objective</h3>\\n \\n <p>To evaluate the feasibility of the point-of-care viscoelastic coagulation monitor (VCM) in Amazon parrots (<i>Amazona</i> spp.) and describe the parameters with fresh whole-blood samples in healthy Amazon parrots.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Design</h3>\\n \\n <p>A total of 18 Amazon parrots were enrolled. Physical examinations, a CBC, and a biochemistry profile, including bile acids, were performed on all parrots. VCM tracings were obtained at the time of venipuncture for baseline laboratory work.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Measurements and Main Results</h3>\\n \\n <p>The median clot time was 2102 seconds (range: 38.6–3599 s), median clot formation time was 929 seconds (range: 21.4–1711 s), median alpha angle was 20 (range: 6–67), and the median maximum clot formation was 8.5 (range: 0–36). The median lysis index at 30 minutes (LI30) was 100 (range: 98–100), and the median lysis index at 45 minutes (LI45) was 100 (range: 90–100). Of 18 samples, alpha angles were not reported in 7 samples, LI30 was not reported in 10 samples, and LI45 was not reported in 12 samples. Of the qualitative curves, 6 reflected normal mammalian curves, and the remainder were consistent with a hypocoaguable state.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>The results were markedly variable, with the majority of VCM tracings being hypocoagulable in comparison with reference intervals established for dogs and cats. Using these protocols, the VCM is not reliable in Amazon parrots. Future areas of investigation include altering the temperature during sample analysis, the use of activators, or an exchange of clotting reagents for an extrinsic pathway activator, which may contribute to the success of this device in avian species.</p>\\n </section>\\n </div>\",\"PeriodicalId\":17603,\"journal\":{\"name\":\"Journal of veterinary emergency and critical care\",\"volume\":\"34 3\",\"pages\":\"238-244\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-05-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of veterinary emergency and critical care\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/vec.13386\",\"RegionNum\":3,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of veterinary emergency and critical care","FirstCategoryId":"97","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/vec.13386","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估亚马逊鹦鹉(Amazonapp:评估亚马逊鹦鹉(Amazona spp.)护理点粘弹性凝血监测仪(VCM)的可行性,并描述健康亚马逊鹦鹉新鲜全血样本的参数:设计:共招募了 18 只亚马逊鹦鹉。设计:共招募了 18 只亚马逊鹦鹉,对所有鹦鹉进行了体格检查、全血细胞计数和生化分析(包括胆汁酸)。在静脉穿刺时采集 VCM 曲线,用于基线实验室工作:凝血时间中位数为 2102 秒(范围:38.6-3599 秒),凝血形成时间中位数为 929 秒(范围:21.4-1711 秒),α角中位数为 20(范围:6-67),凝血形成最大值中位数为 8.5(范围:0-36)。30 分钟裂解指数(LI30)的中位数为 100(范围:98-100),45 分钟裂解指数(LI45)的中位数为 100(范围:90-100)。在 18 个样本中,7 个样本未报告α角,10 个样本未报告 LI30,12 个样本未报告 LI45。在定性曲线中,有 6 个反映了哺乳动物的正常曲线,其余的则符合低凝状态:结论:结果差异明显,与为狗和猫建立的参考区间相比,大多数 VCM 曲线都处于低凝状态。使用这些方案,亚马逊鹦鹉的 VCM 并不可靠。未来的研究领域包括在样本分析过程中改变温度、使用激活剂或将凝血试剂换成外在途径激活剂,这可能有助于该设备在鸟类中取得成功。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Point-of-care viscoelastic coagulation monitor parameters in Amazon parrots (Amazona spp.)

Objective

To evaluate the feasibility of the point-of-care viscoelastic coagulation monitor (VCM) in Amazon parrots (Amazona spp.) and describe the parameters with fresh whole-blood samples in healthy Amazon parrots.

Design

A total of 18 Amazon parrots were enrolled. Physical examinations, a CBC, and a biochemistry profile, including bile acids, were performed on all parrots. VCM tracings were obtained at the time of venipuncture for baseline laboratory work.

Measurements and Main Results

The median clot time was 2102 seconds (range: 38.6–3599 s), median clot formation time was 929 seconds (range: 21.4–1711 s), median alpha angle was 20 (range: 6–67), and the median maximum clot formation was 8.5 (range: 0–36). The median lysis index at 30 minutes (LI30) was 100 (range: 98–100), and the median lysis index at 45 minutes (LI45) was 100 (range: 90–100). Of 18 samples, alpha angles were not reported in 7 samples, LI30 was not reported in 10 samples, and LI45 was not reported in 12 samples. Of the qualitative curves, 6 reflected normal mammalian curves, and the remainder were consistent with a hypocoaguable state.

Conclusions

The results were markedly variable, with the majority of VCM tracings being hypocoagulable in comparison with reference intervals established for dogs and cats. Using these protocols, the VCM is not reliable in Amazon parrots. Future areas of investigation include altering the temperature during sample analysis, the use of activators, or an exchange of clotting reagents for an extrinsic pathway activator, which may contribute to the success of this device in avian species.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.50
自引率
15.40%
发文量
121
审稿时长
18-36 weeks
期刊介绍: The Journal of Veterinary Emergency and Critical Care’s primary aim is to advance the international clinical standard of care for emergency/critical care patients of all species. The journal’s content is relevant to specialist and non-specialist veterinarians practicing emergency/critical care medicine. The journal achieves it aims by publishing descriptions of unique presentation or management; retrospective and prospective evaluations of prognosis, novel diagnosis, or therapy; translational basic science studies with clinical relevance; in depth reviews of pertinent topics; topical news and letters; and regular themed issues. The journal is the official publication of the Veterinary Emergency and Critical Care Society, the American College of Veterinary Emergency and Critical Care, the European Veterinary Emergency and Critical Care Society, and the European College of Veterinary Emergency and Critical Care. It is a bimonthly publication with international impact and adheres to currently accepted ethical standards.
期刊最新文献
Fabio Viganó Jennifer J. Devey Issue Information - Prelim AUTHOR INDEX Abstracts from the International Veterinary Emergency and Critical Care Symposium and the European Veterinary Emergency and Critical Care Annual Congress 2024
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1