{"title":"葡萄糖监测的进展:基于 ZnO-Nanoflakes 薄膜的高灵敏度可穿戴生物传感器,用于基于汗液的无创糖尿病护理点监测","authors":"G M Mehedi Hossain, A. Jalal, Nezih Pala, Fahmida Alam","doi":"10.1149/11313.0035ecst","DOIUrl":null,"url":null,"abstract":"In the contemporary global landscape, diabetes is a concerning presence that contributes to noteworthy mortality rates. The etiology of this condition involves a subtle interaction between insulin deficiency and elevated blood sugar levels. Against this backdrop, the necessity for prompt, accurate, and continuous noninvasive monitoring of glucose concentrations becomes notably evident. The electrochemical flexible glucose biosensor was fabricated by immobilizing glucose oxidase (GOx) on ZnO nanoflakes, possessing a 20nm thickness, and synthesized on an Au-coated stretchable PET film. The sensitivity of the flexible biosensor was determined by 29.97μA/decade/cm², and the minimum detection limit was 1μM. The coefficient of determination was 97.76%, which is significantly linear.","PeriodicalId":11473,"journal":{"name":"ECS Transactions","volume":"3 7","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Advancements in Glucose Monitoring: A Thin Film ZnO-Nanoflakes Based Highly Sensitive Wearable Biosensor for Noninvasive Sweat-Based Point-of-Care Monitoring for Diabetes\",\"authors\":\"G M Mehedi Hossain, A. Jalal, Nezih Pala, Fahmida Alam\",\"doi\":\"10.1149/11313.0035ecst\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the contemporary global landscape, diabetes is a concerning presence that contributes to noteworthy mortality rates. The etiology of this condition involves a subtle interaction between insulin deficiency and elevated blood sugar levels. Against this backdrop, the necessity for prompt, accurate, and continuous noninvasive monitoring of glucose concentrations becomes notably evident. The electrochemical flexible glucose biosensor was fabricated by immobilizing glucose oxidase (GOx) on ZnO nanoflakes, possessing a 20nm thickness, and synthesized on an Au-coated stretchable PET film. The sensitivity of the flexible biosensor was determined by 29.97μA/decade/cm², and the minimum detection limit was 1μM. The coefficient of determination was 97.76%, which is significantly linear.\",\"PeriodicalId\":11473,\"journal\":{\"name\":\"ECS Transactions\",\"volume\":\"3 7\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ECS Transactions\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1149/11313.0035ecst\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ECS Transactions","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1149/11313.0035ecst","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
在当代全球范围内,糖尿病是一种令人担忧的疾病,它导致了显著的死亡率。这种疾病的病因涉及胰岛素缺乏和血糖水平升高之间微妙的相互作用。在此背景下,对葡萄糖浓度进行及时、准确和连续的无创监测就显得尤为必要。电化学柔性葡萄糖生物传感器是通过将葡萄糖氧化酶(GOx)固定在厚度为 20nm 的氧化锌纳米片上,并合成在镀金的可拉伸 PET 薄膜上制成的。柔性生物传感器的灵敏度为 29.97μA/decade/cm² ,最低检测限为 1μM。测定系数为 97.76%,具有明显的线性。
Advancements in Glucose Monitoring: A Thin Film ZnO-Nanoflakes Based Highly Sensitive Wearable Biosensor for Noninvasive Sweat-Based Point-of-Care Monitoring for Diabetes
In the contemporary global landscape, diabetes is a concerning presence that contributes to noteworthy mortality rates. The etiology of this condition involves a subtle interaction between insulin deficiency and elevated blood sugar levels. Against this backdrop, the necessity for prompt, accurate, and continuous noninvasive monitoring of glucose concentrations becomes notably evident. The electrochemical flexible glucose biosensor was fabricated by immobilizing glucose oxidase (GOx) on ZnO nanoflakes, possessing a 20nm thickness, and synthesized on an Au-coated stretchable PET film. The sensitivity of the flexible biosensor was determined by 29.97μA/decade/cm², and the minimum detection limit was 1μM. The coefficient of determination was 97.76%, which is significantly linear.