选择性激光熔融 Ti6Al4V-奎宁骨纳米复合材料的摩擦和磨损行为

IF 1.1 4区 材料科学 Q4 MATERIALS SCIENCE, MULTIDISCIPLINARY Korean Journal of Metals and Materials Pub Date : 2024-05-05 DOI:10.3365/kjmm.2024.62.5.351
Se-Hee Kim, Suhyun Bae, Sang-Bae Park, Hoon Seonwoo, Se-Eun Shin
{"title":"选择性激光熔融 Ti6Al4V-奎宁骨纳米复合材料的摩擦和磨损行为","authors":"Se-Hee Kim, Suhyun Bae, Sang-Bae Park, Hoon Seonwoo, Se-Eun Shin","doi":"10.3365/kjmm.2024.62.5.351","DOIUrl":null,"url":null,"abstract":"Ti6Al4V is commonly used in implants because of its excellent mechanical properties, corrosion resistance, and biocompatibility. While Hydroxyapatite (HAp) is typically used for strong biological bonding between Ti6Al4V implants and bone tissue, this study takes a different approach by incorporating Equine Bone (EB), which has a chemical structure similar to human bone tissue, as a substitute for HAp. In this study, to develop implant materials with a low elastic modulus, high strength, and excellent wear resistance, Ti6Al4V used in biomedical applications was combined with natural EB. Subsequently, a Ti6Al4V-0.05EB composite was fabricated using ball milling followed by Selective Laser Melting (SLM). SLM can reproduce even the interior of a 3D structure, so various studies are being conducted to apply it as a biomaterial. However, Ti6Al4V alloys produced by SLM are known to have low ductility due to localized heat gradients, rapid solidification, and cooling rates. This reduced ductility can result in decreased formability of biomaterials, and the high elastic modulus may lead to stress shielding phenomena, potentially reducing the lifespan of the biomaterial. To minimize this, a post-heat treatment was applied to the Ti6Al4V-0.05EB composite material manufactured by SLM. Afterwards, the microstructure, mechanical properties, and wear resistance, which are important in biomaterials, were evaluated.","PeriodicalId":17894,"journal":{"name":"Korean Journal of Metals and Materials","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Friction and Wear Behavior of Selective Laser Melted Ti6Al4V-Equine Bone Nanocomposites\",\"authors\":\"Se-Hee Kim, Suhyun Bae, Sang-Bae Park, Hoon Seonwoo, Se-Eun Shin\",\"doi\":\"10.3365/kjmm.2024.62.5.351\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ti6Al4V is commonly used in implants because of its excellent mechanical properties, corrosion resistance, and biocompatibility. While Hydroxyapatite (HAp) is typically used for strong biological bonding between Ti6Al4V implants and bone tissue, this study takes a different approach by incorporating Equine Bone (EB), which has a chemical structure similar to human bone tissue, as a substitute for HAp. In this study, to develop implant materials with a low elastic modulus, high strength, and excellent wear resistance, Ti6Al4V used in biomedical applications was combined with natural EB. Subsequently, a Ti6Al4V-0.05EB composite was fabricated using ball milling followed by Selective Laser Melting (SLM). SLM can reproduce even the interior of a 3D structure, so various studies are being conducted to apply it as a biomaterial. However, Ti6Al4V alloys produced by SLM are known to have low ductility due to localized heat gradients, rapid solidification, and cooling rates. This reduced ductility can result in decreased formability of biomaterials, and the high elastic modulus may lead to stress shielding phenomena, potentially reducing the lifespan of the biomaterial. To minimize this, a post-heat treatment was applied to the Ti6Al4V-0.05EB composite material manufactured by SLM. Afterwards, the microstructure, mechanical properties, and wear resistance, which are important in biomaterials, were evaluated.\",\"PeriodicalId\":17894,\"journal\":{\"name\":\"Korean Journal of Metals and Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2024-05-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Korean Journal of Metals and Materials\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.3365/kjmm.2024.62.5.351\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MATERIALS SCIENCE, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Metals and Materials","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.3365/kjmm.2024.62.5.351","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

Ti6Al4V 因其优异的机械性能、耐腐蚀性和生物相容性而常用于植入物。羟基磷灰石(HAp)通常用于在 Ti6Al4V 植入体和骨组织之间建立牢固的生物结合,而本研究则采用了一种不同的方法,将化学结构与人体骨组织相似的马骨(EB)作为 HAp 的替代品。在这项研究中,为了开发具有低弹性模量、高强度和优异耐磨性的植入体材料,将生物医学应用中使用的 Ti6Al4V 与天然 EB 结合在一起。随后,利用球磨和选择性激光熔融(SLM)技术制造出了 Ti6Al4V-0.05EB 复合材料。选择性激光熔融(SLM)甚至可以再现三维结构的内部,因此,人们正在开展各种研究,将其用作生物材料。然而,由于局部热梯度、快速凝固和冷却速度等原因,通过 SLM 生产的 Ti6Al4V 合金的延展性较低。延展性降低会导致生物材料的可成形性降低,而高弹性模量可能会导致应力屏蔽现象,从而可能缩短生物材料的使用寿命。为了尽量减少这种情况,对 SLM 制造的 Ti6Al4V-0.05EB 复合材料进行了后热处理。随后,对生物材料中重要的微观结构、机械性能和耐磨性进行了评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Friction and Wear Behavior of Selective Laser Melted Ti6Al4V-Equine Bone Nanocomposites
Ti6Al4V is commonly used in implants because of its excellent mechanical properties, corrosion resistance, and biocompatibility. While Hydroxyapatite (HAp) is typically used for strong biological bonding between Ti6Al4V implants and bone tissue, this study takes a different approach by incorporating Equine Bone (EB), which has a chemical structure similar to human bone tissue, as a substitute for HAp. In this study, to develop implant materials with a low elastic modulus, high strength, and excellent wear resistance, Ti6Al4V used in biomedical applications was combined with natural EB. Subsequently, a Ti6Al4V-0.05EB composite was fabricated using ball milling followed by Selective Laser Melting (SLM). SLM can reproduce even the interior of a 3D structure, so various studies are being conducted to apply it as a biomaterial. However, Ti6Al4V alloys produced by SLM are known to have low ductility due to localized heat gradients, rapid solidification, and cooling rates. This reduced ductility can result in decreased formability of biomaterials, and the high elastic modulus may lead to stress shielding phenomena, potentially reducing the lifespan of the biomaterial. To minimize this, a post-heat treatment was applied to the Ti6Al4V-0.05EB composite material manufactured by SLM. Afterwards, the microstructure, mechanical properties, and wear resistance, which are important in biomaterials, were evaluated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Korean Journal of Metals and Materials
Korean Journal of Metals and Materials MATERIALS SCIENCE, MULTIDISCIPLINARY-METALLURGY & METALLURGICAL ENGINEERING
CiteScore
1.80
自引率
58.30%
发文量
100
审稿时长
4-8 weeks
期刊介绍: The Korean Journal of Metals and Materials is a representative Korean-language journal of the Korean Institute of Metals and Materials (KIM); it publishes domestic and foreign academic papers related to metals and materials, in abroad range of fields from metals and materials to nano-materials, biomaterials, functional materials, energy materials, and new materials, and its official ISO designation is Korean J. Met. Mater.
期刊最新文献
Solidification Behavior and Mechanical Properties of Sn-2.5Ag-0.8Cu-0.05Ni-1Bi and Sn-0.75Cu-0.065Ni-1.5Bi Solder Alloys, and Microstructures in Joints Formed Using Them Microstructure and Texture Evolution in Thermomechanically Processed FCC Metals and Alloys: a Review Theoretical Maximum Thermoelectric Performance of Cu-doped and Electric Current Pulse-treated Bi-Sb-Te Alloys Investigation on the Structural and Mechanical Properties of Al Foam Manufactured by Spark Plasma Sintering and Compression Molding Methods Skutterudite: Reproducibility of Thermoelectric Performance of P-type RyFe4-xCoxSb12 Bulky Compacts
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1