{"title":"在盐水饱和多孔介质置换过程中对纯净和粘化二氧化碳的时空 X 射线成像","authors":"Boxin Ding, A. Kantzas, A. Firoozabadi","doi":"10.2118/214842-pa","DOIUrl":null,"url":null,"abstract":"\n CO2 storage in saline aquifers may contribute to a 90% share in preventing emissions to the atmosphere. Due to low CO2 viscosity at the subsurface often found in supercritical (sc) conditions, the injected CO2 may spread quickly at the formation top and increase the probability of leakage. This work relates to improved CO2 storage in saline aquifers by effective viscosification of the sc-CO2 at very low concentrations of engineered oligomers and the effectiveness of slug injection of viscosified CO2 (vis-CO2). We present the results from X-ray computed tomography (CT) imaging to advance the understanding of two-phase CO2-brine flow in porous media and firmly establish the transport mechanisms.\n X-ray CT imaging of displacement experiments is conducted to quantify the in-situ sc-CO2 saturation spatiotemporally. In neat CO2 injection, gravity override and adverse mobility ratio may result in early breakthrough and low sweep efficiency. We find cumulative brine production from the fraction collector to be lower than X-ray CT imaging at 2 pore volume (PV) injection. The difference between the two is attributed to the solubility of the produced water in the produced CO2 at atmospheric pressure. We show that when the solubility is accounted for, there is a good agreement between direct measurements and in-situ saturation results.\n There are three reports (two by the same group) that oligomers of 1-decene (O1D) with six repeat units may have marginal CO2 viscosification. The majority of published work by other groups shows that O1D with six repeat units and higher are effective CO2 viscosifiers. In the past, we have demonstrated the effectiveness of an O1D in the displacement of brine by CO2 at a concentration of 1.5 wt%. The effectiveness is examined and identified by three different methods. In this work, we show that the same oligomer is effective at a low concentration of 0.6 wt%. The oligomer slows the breakthrough by 1.6 times and improves the brine production by 34% in the horizontal orientation. X-ray CT imaging results reveal that such a large effect may be from the increase in the interfacial elasticity. We also show that there is no need for continuous injection of the oligomer. A slug of 0.3 PV injection (PVI) of vis-CO2 followed by neat CO2 injection has the same effectiveness as the continuous injection of the vis-CO2. In this work, we also demonstrate the effectiveness of a new engineered molecule at 0.3 wt% that may increase residual trapping by about 35%. The combination of mobility control and residual brine saturation reduction is expected to improve CO2 storage by effective viscosification with low concentrations of oligomers.","PeriodicalId":22252,"journal":{"name":"SPE Journal","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Spatiotemporal X-Ray Imaging of Neat and Viscosified CO2 in Displacement of Brine-Saturated Porous Media\",\"authors\":\"Boxin Ding, A. Kantzas, A. Firoozabadi\",\"doi\":\"10.2118/214842-pa\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n CO2 storage in saline aquifers may contribute to a 90% share in preventing emissions to the atmosphere. Due to low CO2 viscosity at the subsurface often found in supercritical (sc) conditions, the injected CO2 may spread quickly at the formation top and increase the probability of leakage. This work relates to improved CO2 storage in saline aquifers by effective viscosification of the sc-CO2 at very low concentrations of engineered oligomers and the effectiveness of slug injection of viscosified CO2 (vis-CO2). We present the results from X-ray computed tomography (CT) imaging to advance the understanding of two-phase CO2-brine flow in porous media and firmly establish the transport mechanisms.\\n X-ray CT imaging of displacement experiments is conducted to quantify the in-situ sc-CO2 saturation spatiotemporally. In neat CO2 injection, gravity override and adverse mobility ratio may result in early breakthrough and low sweep efficiency. We find cumulative brine production from the fraction collector to be lower than X-ray CT imaging at 2 pore volume (PV) injection. The difference between the two is attributed to the solubility of the produced water in the produced CO2 at atmospheric pressure. We show that when the solubility is accounted for, there is a good agreement between direct measurements and in-situ saturation results.\\n There are three reports (two by the same group) that oligomers of 1-decene (O1D) with six repeat units may have marginal CO2 viscosification. The majority of published work by other groups shows that O1D with six repeat units and higher are effective CO2 viscosifiers. In the past, we have demonstrated the effectiveness of an O1D in the displacement of brine by CO2 at a concentration of 1.5 wt%. The effectiveness is examined and identified by three different methods. In this work, we show that the same oligomer is effective at a low concentration of 0.6 wt%. The oligomer slows the breakthrough by 1.6 times and improves the brine production by 34% in the horizontal orientation. X-ray CT imaging results reveal that such a large effect may be from the increase in the interfacial elasticity. We also show that there is no need for continuous injection of the oligomer. A slug of 0.3 PV injection (PVI) of vis-CO2 followed by neat CO2 injection has the same effectiveness as the continuous injection of the vis-CO2. In this work, we also demonstrate the effectiveness of a new engineered molecule at 0.3 wt% that may increase residual trapping by about 35%. The combination of mobility control and residual brine saturation reduction is expected to improve CO2 storage by effective viscosification with low concentrations of oligomers.\",\"PeriodicalId\":22252,\"journal\":{\"name\":\"SPE Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"SPE Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.2118/214842-pa\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, PETROLEUM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"SPE Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2118/214842-pa","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, PETROLEUM","Score":null,"Total":0}
Spatiotemporal X-Ray Imaging of Neat and Viscosified CO2 in Displacement of Brine-Saturated Porous Media
CO2 storage in saline aquifers may contribute to a 90% share in preventing emissions to the atmosphere. Due to low CO2 viscosity at the subsurface often found in supercritical (sc) conditions, the injected CO2 may spread quickly at the formation top and increase the probability of leakage. This work relates to improved CO2 storage in saline aquifers by effective viscosification of the sc-CO2 at very low concentrations of engineered oligomers and the effectiveness of slug injection of viscosified CO2 (vis-CO2). We present the results from X-ray computed tomography (CT) imaging to advance the understanding of two-phase CO2-brine flow in porous media and firmly establish the transport mechanisms.
X-ray CT imaging of displacement experiments is conducted to quantify the in-situ sc-CO2 saturation spatiotemporally. In neat CO2 injection, gravity override and adverse mobility ratio may result in early breakthrough and low sweep efficiency. We find cumulative brine production from the fraction collector to be lower than X-ray CT imaging at 2 pore volume (PV) injection. The difference between the two is attributed to the solubility of the produced water in the produced CO2 at atmospheric pressure. We show that when the solubility is accounted for, there is a good agreement between direct measurements and in-situ saturation results.
There are three reports (two by the same group) that oligomers of 1-decene (O1D) with six repeat units may have marginal CO2 viscosification. The majority of published work by other groups shows that O1D with six repeat units and higher are effective CO2 viscosifiers. In the past, we have demonstrated the effectiveness of an O1D in the displacement of brine by CO2 at a concentration of 1.5 wt%. The effectiveness is examined and identified by three different methods. In this work, we show that the same oligomer is effective at a low concentration of 0.6 wt%. The oligomer slows the breakthrough by 1.6 times and improves the brine production by 34% in the horizontal orientation. X-ray CT imaging results reveal that such a large effect may be from the increase in the interfacial elasticity. We also show that there is no need for continuous injection of the oligomer. A slug of 0.3 PV injection (PVI) of vis-CO2 followed by neat CO2 injection has the same effectiveness as the continuous injection of the vis-CO2. In this work, we also demonstrate the effectiveness of a new engineered molecule at 0.3 wt% that may increase residual trapping by about 35%. The combination of mobility control and residual brine saturation reduction is expected to improve CO2 storage by effective viscosification with low concentrations of oligomers.
期刊介绍:
Covers theories and emerging concepts spanning all aspects of engineering for oil and gas exploration and production, including reservoir characterization, multiphase flow, drilling dynamics, well architecture, gas well deliverability, numerical simulation, enhanced oil recovery, CO2 sequestration, and benchmarking and performance indicators.