{"title":"膨胀涂料的耐久性和工作寿命超过 10 年的测试概念建议","authors":"Dustin Häßler ,&nbsp;Maximilian Mund ,&nbsp;Lars-Hendrik Daus ,&nbsp;Sascha Hothan ,&nbsp;Peter Schaumann ,&nbsp;Bernhard Schartel","doi":"10.1016/j.firesaf.2024.104173","DOIUrl":null,"url":null,"abstract":"<div><p>It is an essential requirement for all building products to ensure durability of their fire safety. Throughout the working life of products, intumescent coatings are aged by certain climatic factors. To predict a lifetime of several years, generally the behaviour of the intumescent coating is extrapolated based on accelerated artificial ageing. The established German and European procedures to assess the durability assume a working life of at least 10 years. For a longer period, additional evidence is required; yet the procedure and the specifications to justify this are not described. In addition to addressing this formal lack, from a scientific point of view it is necessary to investigate the degradation of intumescent coatings in detail and to propose a reliable test concept to assess durability for more than 10 years. This paper summarises the existing knowledge about the ageing of intumescent coatings. The results of various demanding weathering approaches are presented for two intumescent coatings tested in a joint research project. Moreover, formulations with a reduced amount of functionally relevant components were analysed to gain insight into the associated effects. Derived from these research results and knowledge, recommendations are proposed to assess the durability of intumescent coatings for more than 10 years based on a combination of verifications.</p></div>","PeriodicalId":50445,"journal":{"name":"Fire Safety Journal","volume":"146 ","pages":"Article 104173"},"PeriodicalIF":3.4000,"publicationDate":"2024-05-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0379711224000869/pdfft?md5=24c74ab8a36a4cf4a54f8325b7e80129&pid=1-s2.0-S0379711224000869-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Durability of intumescent coatings and recommendations for test concepts for a working life of more than 10 years\",\"authors\":\"Dustin Häßler ,&nbsp;Maximilian Mund ,&nbsp;Lars-Hendrik Daus ,&nbsp;Sascha Hothan ,&nbsp;Peter Schaumann ,&nbsp;Bernhard Schartel\",\"doi\":\"10.1016/j.firesaf.2024.104173\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>It is an essential requirement for all building products to ensure durability of their fire safety. Throughout the working life of products, intumescent coatings are aged by certain climatic factors. To predict a lifetime of several years, generally the behaviour of the intumescent coating is extrapolated based on accelerated artificial ageing. The established German and European procedures to assess the durability assume a working life of at least 10 years. For a longer period, additional evidence is required; yet the procedure and the specifications to justify this are not described. In addition to addressing this formal lack, from a scientific point of view it is necessary to investigate the degradation of intumescent coatings in detail and to propose a reliable test concept to assess durability for more than 10 years. This paper summarises the existing knowledge about the ageing of intumescent coatings. The results of various demanding weathering approaches are presented for two intumescent coatings tested in a joint research project. Moreover, formulations with a reduced amount of functionally relevant components were analysed to gain insight into the associated effects. Derived from these research results and knowledge, recommendations are proposed to assess the durability of intumescent coatings for more than 10 years based on a combination of verifications.</p></div>\",\"PeriodicalId\":50445,\"journal\":{\"name\":\"Fire Safety Journal\",\"volume\":\"146 \",\"pages\":\"Article 104173\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-05-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0379711224000869/pdfft?md5=24c74ab8a36a4cf4a54f8325b7e80129&pid=1-s2.0-S0379711224000869-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fire Safety Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0379711224000869\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Safety Journal","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0379711224000869","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

摘要

确保防火安全的耐久性是所有建筑产品的基本要求。在产品的整个使用寿命期间,膨胀涂层会因某些气候因素而老化。为了预测数年的使用寿命,通常会根据人工加速老化推断膨胀涂层的性能。德国和欧洲评估耐久性的既定程序假定工作寿命至少为 10 年。如果需要更长的时间,则需要更多的证据;但没有说明证明这一点的程序和规格。除了解决这一形式上的不足,从科学的角度来看,有必要对膨胀涂层的降解进行详细研究,并提出一个可靠的测试概念,以评估超过 10 年的耐久性。本文总结了有关膨胀涂层老化的现有知识。文中介绍了在一个联合研究项目中对两种膨胀涂料进行测试的各种苛刻老化方法的结果。此外,还分析了功能相关成分用量减少的配方,以深入了解相关影响。根据这些研究成果和知识,提出了一些建议,以便在综合验证的基础上评估膨胀涂料 10 年以上的耐久性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Durability of intumescent coatings and recommendations for test concepts for a working life of more than 10 years

It is an essential requirement for all building products to ensure durability of their fire safety. Throughout the working life of products, intumescent coatings are aged by certain climatic factors. To predict a lifetime of several years, generally the behaviour of the intumescent coating is extrapolated based on accelerated artificial ageing. The established German and European procedures to assess the durability assume a working life of at least 10 years. For a longer period, additional evidence is required; yet the procedure and the specifications to justify this are not described. In addition to addressing this formal lack, from a scientific point of view it is necessary to investigate the degradation of intumescent coatings in detail and to propose a reliable test concept to assess durability for more than 10 years. This paper summarises the existing knowledge about the ageing of intumescent coatings. The results of various demanding weathering approaches are presented for two intumescent coatings tested in a joint research project. Moreover, formulations with a reduced amount of functionally relevant components were analysed to gain insight into the associated effects. Derived from these research results and knowledge, recommendations are proposed to assess the durability of intumescent coatings for more than 10 years based on a combination of verifications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Fire Safety Journal
Fire Safety Journal 工程技术-材料科学:综合
CiteScore
5.70
自引率
9.70%
发文量
153
审稿时长
60 days
期刊介绍: Fire Safety Journal is the leading publication dealing with all aspects of fire safety engineering. Its scope is purposefully wide, as it is deemed important to encourage papers from all sources within this multidisciplinary subject, thus providing a forum for its further development as a distinct engineering discipline. This is an essential step towards gaining a status equal to that enjoyed by the other engineering disciplines.
期刊最新文献
Numerical investigation of the influence of thermal runaway modelling on car park fire hazard and application to a Lithium-ion Manganese Oxide battery Analysis of air consumption and moving speed by firefighters during full-scale search & rescue experiments in a tunnel Numerical simulation of fire spread in a large-scale open CLT compartment Soot modeling in the numerical simulation of buoyant diffusion flames and fires—A review Experimental study to assess the impact of different connection types on the fire resistance of composite concrete-topped CLT slabs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1