{"title":"地下结构-地下连续墙系统中分段隔离层的抗震和振动控制","authors":"Zhidong Gao , Mingbo Li , Mi Zhao , Xiuli Du","doi":"10.1016/j.undsp.2024.02.002","DOIUrl":null,"url":null,"abstract":"<div><p>In this paper, a seismic and vibration reduction measure of subway station is developed by setting a segmented isolation layer between the sidewall of structure and the diaphragm wall. The segmented isolation layer consists of a rigid layer and a flexible layer. The rigid layer is installed at the joint section between the structural sidewall and slab, and the flexible layer is installed at the remaining sections. A diaphragm wall-segmented isolation layer-subway station structure system is constructed. Seismic and vibration control performance of the diaphragm wall-segmented isolation layer-subway station structure system is evaluated by the detailed numerical analysis. Firstly, a three-dimensional nonlinear time-history analysis is carried out to study the seismic response of the station structure by considering the effect of different earthquake motions and stiffness of segmented isolation layer. Subsequently, the vibration response of site under training loading is also studied by considering the influence of different train velocities and stiffness of the segmented isolation layer. Numerical results demonstrate that the diaphragm wall-segmented isolation layer-subway station structure system can not only effectively reduce the lateral deformation of station structure, but also reduce the tensile damage of the roof slab. On the other hand, the developed reduction measure can also significantly reduce the vertical peak displacements of site under training loading.</p></div>","PeriodicalId":48505,"journal":{"name":"Underground Space","volume":"19 ","pages":"Pages 72-86"},"PeriodicalIF":8.2000,"publicationDate":"2024-05-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2467967424000539/pdfft?md5=24e30c9c07258b082f76dad6e5a6eda3&pid=1-s2.0-S2467967424000539-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Seismic and vibration control of segmented isolation layer in underground structure-diaphragm wall system\",\"authors\":\"Zhidong Gao , Mingbo Li , Mi Zhao , Xiuli Du\",\"doi\":\"10.1016/j.undsp.2024.02.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In this paper, a seismic and vibration reduction measure of subway station is developed by setting a segmented isolation layer between the sidewall of structure and the diaphragm wall. The segmented isolation layer consists of a rigid layer and a flexible layer. The rigid layer is installed at the joint section between the structural sidewall and slab, and the flexible layer is installed at the remaining sections. A diaphragm wall-segmented isolation layer-subway station structure system is constructed. Seismic and vibration control performance of the diaphragm wall-segmented isolation layer-subway station structure system is evaluated by the detailed numerical analysis. Firstly, a three-dimensional nonlinear time-history analysis is carried out to study the seismic response of the station structure by considering the effect of different earthquake motions and stiffness of segmented isolation layer. Subsequently, the vibration response of site under training loading is also studied by considering the influence of different train velocities and stiffness of the segmented isolation layer. Numerical results demonstrate that the diaphragm wall-segmented isolation layer-subway station structure system can not only effectively reduce the lateral deformation of station structure, but also reduce the tensile damage of the roof slab. On the other hand, the developed reduction measure can also significantly reduce the vertical peak displacements of site under training loading.</p></div>\",\"PeriodicalId\":48505,\"journal\":{\"name\":\"Underground Space\",\"volume\":\"19 \",\"pages\":\"Pages 72-86\"},\"PeriodicalIF\":8.2000,\"publicationDate\":\"2024-05-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2467967424000539/pdfft?md5=24e30c9c07258b082f76dad6e5a6eda3&pid=1-s2.0-S2467967424000539-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Underground Space\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2467967424000539\",\"RegionNum\":1,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Underground Space","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2467967424000539","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
Seismic and vibration control of segmented isolation layer in underground structure-diaphragm wall system
In this paper, a seismic and vibration reduction measure of subway station is developed by setting a segmented isolation layer between the sidewall of structure and the diaphragm wall. The segmented isolation layer consists of a rigid layer and a flexible layer. The rigid layer is installed at the joint section between the structural sidewall and slab, and the flexible layer is installed at the remaining sections. A diaphragm wall-segmented isolation layer-subway station structure system is constructed. Seismic and vibration control performance of the diaphragm wall-segmented isolation layer-subway station structure system is evaluated by the detailed numerical analysis. Firstly, a three-dimensional nonlinear time-history analysis is carried out to study the seismic response of the station structure by considering the effect of different earthquake motions and stiffness of segmented isolation layer. Subsequently, the vibration response of site under training loading is also studied by considering the influence of different train velocities and stiffness of the segmented isolation layer. Numerical results demonstrate that the diaphragm wall-segmented isolation layer-subway station structure system can not only effectively reduce the lateral deformation of station structure, but also reduce the tensile damage of the roof slab. On the other hand, the developed reduction measure can also significantly reduce the vertical peak displacements of site under training loading.
期刊介绍:
Underground Space is an open access international journal without article processing charges (APC) committed to serving as a scientific forum for researchers and practitioners in the field of underground engineering. The journal welcomes manuscripts that deal with original theories, methods, technologies, and important applications throughout the life-cycle of underground projects, including planning, design, operation and maintenance, disaster prevention, and demolition. The journal is particularly interested in manuscripts related to the latest development of smart underground engineering from the perspectives of resilience, resources saving, environmental friendliness, humanity, and artificial intelligence. The manuscripts are expected to have significant innovation and potential impact in the field of underground engineering, and should have clear association with or application in underground projects.