使用不同类型的鞋测量和分析踝关节固定损伤的地面反作用力分布和肌电图

Noora Fakhri, Prof. Dr. Jumaa Chiad
{"title":"使用不同类型的鞋测量和分析踝关节固定损伤的地面反作用力分布和肌电图","authors":"Noora Fakhri, Prof. Dr. Jumaa Chiad","doi":"10.29194/njes.26040358","DOIUrl":null,"url":null,"abstract":"One of the health issues that many people encounter on a daily basis is bone fracture, which can happen for a number of reasons, such as arthritis, sprains, or external trauma . The patient experiences instability as a result of these issues . Internal fixation is a type of surgery used to support and mend a damaged bone Treatment options include ankle joint fixation, a surgical procedure employing pins, plates, rods, or screws. This study uses gait analysis methods to assess lower limb biomechanics .  Gait analysis is vital for understanding walking patterns and intervention effectiveness. The impact of different shoe designs on ankle mechanics, using the finite element method and ANSYS, is investigated The results of the EMG and the GRF were discussed. \nThis research deepens our understanding of lower limb biomechanics and ankle joint health. By evaluating stress effects and designing custom shoes, it enhances ankle injury treatment and management strategies. \nThe patient, a 70-year-old woman with an internal fixation on her ankle joint, underwent a CT scan of her ankle. The patient underwent a number of experiments to evaluate her stability. EMG was used to determine the muscle stress for a brief period of time, and ground reaction force was then used to determine the pressure of walking. Both EMG and GRF have two walking speeds of1.5and 2 km/h while wearing four different types of shoes. The behavior of the EMG demonstrates that the stress on the muscle increases as walking speed increases, and the results varies depending on the shoe. The patient is afraid to apply pressure to the injured foot, so the health foot has better pressure over the entire foot \n ","PeriodicalId":7470,"journal":{"name":"Al-Nahrain Journal for Engineering Sciences","volume":"138 S250","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement and Analysis of ground reaction forces Distribution and electromyography for Ankle Joint Fixation Injury Using Different Types of Shoes\",\"authors\":\"Noora Fakhri, Prof. Dr. Jumaa Chiad\",\"doi\":\"10.29194/njes.26040358\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"One of the health issues that many people encounter on a daily basis is bone fracture, which can happen for a number of reasons, such as arthritis, sprains, or external trauma . The patient experiences instability as a result of these issues . Internal fixation is a type of surgery used to support and mend a damaged bone Treatment options include ankle joint fixation, a surgical procedure employing pins, plates, rods, or screws. This study uses gait analysis methods to assess lower limb biomechanics .  Gait analysis is vital for understanding walking patterns and intervention effectiveness. The impact of different shoe designs on ankle mechanics, using the finite element method and ANSYS, is investigated The results of the EMG and the GRF were discussed. \\nThis research deepens our understanding of lower limb biomechanics and ankle joint health. By evaluating stress effects and designing custom shoes, it enhances ankle injury treatment and management strategies. \\nThe patient, a 70-year-old woman with an internal fixation on her ankle joint, underwent a CT scan of her ankle. The patient underwent a number of experiments to evaluate her stability. EMG was used to determine the muscle stress for a brief period of time, and ground reaction force was then used to determine the pressure of walking. Both EMG and GRF have two walking speeds of1.5and 2 km/h while wearing four different types of shoes. The behavior of the EMG demonstrates that the stress on the muscle increases as walking speed increases, and the results varies depending on the shoe. The patient is afraid to apply pressure to the injured foot, so the health foot has better pressure over the entire foot \\n \",\"PeriodicalId\":7470,\"journal\":{\"name\":\"Al-Nahrain Journal for Engineering Sciences\",\"volume\":\"138 S250\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Al-Nahrain Journal for Engineering Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29194/njes.26040358\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Al-Nahrain Journal for Engineering Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29194/njes.26040358","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

骨折是许多人每天都会遇到的健康问题之一,发生骨折的原因有很多,如关节炎、扭伤或外部创伤。患者会因这些问题而感到不稳定。内固定是一种用于支撑和修补受损骨骼的手术 治疗方法包括踝关节固定术,这是一种使用销钉、钢板、钢棒或螺钉的外科手术。这项研究使用步态分析方法来评估下肢生物力学。 步态分析对于了解行走模式和干预效果至关重要。本研究使用有限元方法和 ANSYS,研究了不同鞋子设计对踝关节力学的影响,并讨论了肌电图和 GRF 的结果。这项研究加深了我们对下肢生物力学和踝关节健康的理解。通过评估应力效应和设计定制鞋,该研究加强了踝关节损伤的治疗和管理策略。患者是一名踝关节内固定的 70 岁女性,她接受了踝关节 CT 扫描。患者接受了一系列实验来评估其稳定性。肌电图被用来确定短暂时间内的肌肉压力,然后地面反作用力被用来确定行走的压力。肌电图和地面反作用力都有两种行走速度,分别为 1.5 公里/小时和 2 公里/小时,同时穿着四种不同类型的鞋子。肌电图的行为表明,随着行走速度的增加,肌肉所承受的压力也在增加,而且不同鞋的结果也不尽相同。患者不敢对受伤的脚施加压力,因此健康的脚对整个脚的压力更大
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Measurement and Analysis of ground reaction forces Distribution and electromyography for Ankle Joint Fixation Injury Using Different Types of Shoes
One of the health issues that many people encounter on a daily basis is bone fracture, which can happen for a number of reasons, such as arthritis, sprains, or external trauma . The patient experiences instability as a result of these issues . Internal fixation is a type of surgery used to support and mend a damaged bone Treatment options include ankle joint fixation, a surgical procedure employing pins, plates, rods, or screws. This study uses gait analysis methods to assess lower limb biomechanics .  Gait analysis is vital for understanding walking patterns and intervention effectiveness. The impact of different shoe designs on ankle mechanics, using the finite element method and ANSYS, is investigated The results of the EMG and the GRF were discussed. This research deepens our understanding of lower limb biomechanics and ankle joint health. By evaluating stress effects and designing custom shoes, it enhances ankle injury treatment and management strategies. The patient, a 70-year-old woman with an internal fixation on her ankle joint, underwent a CT scan of her ankle. The patient underwent a number of experiments to evaluate her stability. EMG was used to determine the muscle stress for a brief period of time, and ground reaction force was then used to determine the pressure of walking. Both EMG and GRF have two walking speeds of1.5and 2 km/h while wearing four different types of shoes. The behavior of the EMG demonstrates that the stress on the muscle increases as walking speed increases, and the results varies depending on the shoe. The patient is afraid to apply pressure to the injured foot, so the health foot has better pressure over the entire foot  
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Strategies of Nanocarrier-Based Therapeutic Drug Delivery An in-Depth Examination Modalities of Hemodynamic Characteristics in Mechanical Aortic Valve: A Comprehensive Review Article Fabrication of Antimicrobial Hydrogel Using Biodegradable Blended Materials for Skin Applications The effect of different heavy metals pollutants in refinery effluent on corrosion rate of carbon steel Design and Analysis of Composite Biomaterial Bone Graft Plate
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1