Zircos-E®蚀刻剂、二氧化硅涂层和氧化铝气粒磨损对三种不同制备设计的内冠的抗脱落性的影响。

IF 1.7 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Clinical and Experimental Dental Research Pub Date : 2024-05-21 DOI:10.1002/cre2.901
Ahmed Yaseen Alqutaibi, Mohammed Ahmed Alghauli, Karim Dewedar, Mohammed H. AbdElaziz, Samah Saker
{"title":"Zircos-E®蚀刻剂、二氧化硅涂层和氧化铝气粒磨损对三种不同制备设计的内冠的抗脱落性的影响。","authors":"Ahmed Yaseen Alqutaibi,&nbsp;Mohammed Ahmed Alghauli,&nbsp;Karim Dewedar,&nbsp;Mohammed H. AbdElaziz,&nbsp;Samah Saker","doi":"10.1002/cre2.901","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objectives</h3>\n \n <p>The study aimed to evaluate the debonding resistance of three different endocrown designs on molar teeth, using three different zirconia surface pretreatments.</p>\n </section>\n \n <section>\n \n <h3> Material and Method</h3>\n \n <p>Ninety human mandibular first molars were divided into three main groups: endocrowns without ferrule, with 1 mm ferrule, and with 2 mm ferrule. The subgroups were defined by their surface pretreatment method used (<i>n</i> = 15): 50 μm alumina air-particle abrasion, silica coating using 30 μm Cojet™ particles, and Zircos-E® etching. The endocrowns were fabricated using multilayer zirconia ceramic, cemented with self-adhesive resin cement, and subjected to 5000 thermocycles (5–55°C) before debonding. The data obtained were analyzed using a two-way ANOVA.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>All test specimens survived the thermocyclic aging. The results indicated that both the preparation design and the surface treatment had a significant impact on the resistance to debonding of the endocrowns (<i>p</i> &lt; .001). The 2 mm ferrule followed by the 1 mm ferrule designs exhibited the highest debonding resistance, both were superior to the endocrown without ferrule. Zircos-E® etching and silica coating yielded comparable debonding resistance, which were significantly higher than alumina air-particle abrasion. All endocrowns demonstrated a favorable failure mode.</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>All designs and surface treatments showed high debonding resistance for a single restoration. However, ferrule designs with Zircos-E® etching or silica coating may represent better clinical options compared to the nonferrule design or alumina airborne-particle abrasion. Nonetheless, further research, including fatigue testing and evaluations with different luting agents is recommended.</p>\n </section>\n </div>","PeriodicalId":10203,"journal":{"name":"Clinical and Experimental Dental Research","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cre2.901","citationCount":"0","resultStr":"{\"title\":\"The influence of Zircos-E® etchant, silica coating, and alumina air-particle abrasion on the debonding resistance of endocrowns with three different preparation designs\",\"authors\":\"Ahmed Yaseen Alqutaibi,&nbsp;Mohammed Ahmed Alghauli,&nbsp;Karim Dewedar,&nbsp;Mohammed H. AbdElaziz,&nbsp;Samah Saker\",\"doi\":\"10.1002/cre2.901\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Objectives</h3>\\n \\n <p>The study aimed to evaluate the debonding resistance of three different endocrown designs on molar teeth, using three different zirconia surface pretreatments.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Material and Method</h3>\\n \\n <p>Ninety human mandibular first molars were divided into three main groups: endocrowns without ferrule, with 1 mm ferrule, and with 2 mm ferrule. The subgroups were defined by their surface pretreatment method used (<i>n</i> = 15): 50 μm alumina air-particle abrasion, silica coating using 30 μm Cojet™ particles, and Zircos-E® etching. The endocrowns were fabricated using multilayer zirconia ceramic, cemented with self-adhesive resin cement, and subjected to 5000 thermocycles (5–55°C) before debonding. The data obtained were analyzed using a two-way ANOVA.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>All test specimens survived the thermocyclic aging. The results indicated that both the preparation design and the surface treatment had a significant impact on the resistance to debonding of the endocrowns (<i>p</i> &lt; .001). The 2 mm ferrule followed by the 1 mm ferrule designs exhibited the highest debonding resistance, both were superior to the endocrown without ferrule. Zircos-E® etching and silica coating yielded comparable debonding resistance, which were significantly higher than alumina air-particle abrasion. All endocrowns demonstrated a favorable failure mode.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>All designs and surface treatments showed high debonding resistance for a single restoration. However, ferrule designs with Zircos-E® etching or silica coating may represent better clinical options compared to the nonferrule design or alumina airborne-particle abrasion. Nonetheless, further research, including fatigue testing and evaluations with different luting agents is recommended.</p>\\n </section>\\n </div>\",\"PeriodicalId\":10203,\"journal\":{\"name\":\"Clinical and Experimental Dental Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/cre2.901\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical and Experimental Dental Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/cre2.901\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Dental Research","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/cre2.901","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

研究目的该研究旨在评估三种不同氧化锆表面预处理的磨牙内冠设计的抗脱落性:将 90 颗人类下颌第一磨牙分为三大组:无套圈内冠、带 1 毫米套圈内冠和带 2 毫米套圈内冠。根据所使用的表面预处理方法(n = 15)来确定分组:50 μm 氧化铝空气颗粒研磨、使用 30 μm Cojet™ 颗粒的二氧化硅涂层和 Zircos-E® 蚀刻。使用多层氧化锆陶瓷制作内冠,用自粘树脂粘结剂粘结,并在脱粘前进行 5000 次热循环(5-55°C)。所得数据采用双向方差分析:结果:所有试样都经受住了热循环老化。结果表明,制备设计和表面处理对内冠的抗脱落性都有显著影响(p 结论:所有设计和表面处理都显示出较高的抗脱落性:对于单个修复体而言,所有的设计和表面处理都显示出较高的抗脱落性。不过,与非卡环设计或氧化铝空气颗粒磨蚀相比,带有 Zircos-E® 蚀刻或二氧化硅涂层的卡环设计可能是更好的临床选择。尽管如此,还是建议进行进一步的研究,包括疲劳测试和使用不同粘结剂的评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The influence of Zircos-E® etchant, silica coating, and alumina air-particle abrasion on the debonding resistance of endocrowns with three different preparation designs

Objectives

The study aimed to evaluate the debonding resistance of three different endocrown designs on molar teeth, using three different zirconia surface pretreatments.

Material and Method

Ninety human mandibular first molars were divided into three main groups: endocrowns without ferrule, with 1 mm ferrule, and with 2 mm ferrule. The subgroups were defined by their surface pretreatment method used (n = 15): 50 μm alumina air-particle abrasion, silica coating using 30 μm Cojet™ particles, and Zircos-E® etching. The endocrowns were fabricated using multilayer zirconia ceramic, cemented with self-adhesive resin cement, and subjected to 5000 thermocycles (5–55°C) before debonding. The data obtained were analyzed using a two-way ANOVA.

Results

All test specimens survived the thermocyclic aging. The results indicated that both the preparation design and the surface treatment had a significant impact on the resistance to debonding of the endocrowns (p < .001). The 2 mm ferrule followed by the 1 mm ferrule designs exhibited the highest debonding resistance, both were superior to the endocrown without ferrule. Zircos-E® etching and silica coating yielded comparable debonding resistance, which were significantly higher than alumina air-particle abrasion. All endocrowns demonstrated a favorable failure mode.

Conclusions

All designs and surface treatments showed high debonding resistance for a single restoration. However, ferrule designs with Zircos-E® etching or silica coating may represent better clinical options compared to the nonferrule design or alumina airborne-particle abrasion. Nonetheless, further research, including fatigue testing and evaluations with different luting agents is recommended.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical and Experimental Dental Research
Clinical and Experimental Dental Research DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.30
自引率
5.60%
发文量
165
审稿时长
26 weeks
期刊介绍: Clinical and Experimental Dental Research aims to provide open access peer-reviewed publications of high scientific quality representing original clinical, diagnostic or experimental work within all disciplines and fields of oral medicine and dentistry. The scope of Clinical and Experimental Dental Research comprises original research material on the anatomy, physiology and pathology of oro-facial, oro-pharyngeal and maxillofacial tissues, and functions and dysfunctions within the stomatognathic system, and the epidemiology, aetiology, prevention, diagnosis, prognosis and therapy of diseases and conditions that have an effect on the homeostasis of the mouth, jaws, and closely associated structures, as well as the healing and regeneration and the clinical aspects of replacement of hard and soft tissues with biomaterials, and the rehabilitation of stomatognathic functions. Studies that bring new knowledge on how to advance health on the individual or public health levels, including interactions between oral and general health and ill-health are welcome.
期刊最新文献
Artificial Intelligence in Dental Caries Diagnosis and Detection: An Umbrella Review Influence of Different Application Modes of a Universal Adhesive System on the Bond Strength of Bulk-Fill Composite Resin to Enamel and Dentin in Primary Teeth Factors Impacting Quality of Life in a Group of Iranian Patients in Chronic Oral Mucosal Disease Following Treatment? Prevalence of Middle Mesial Canal in Mandibular First Permanent Molars in a Persian Population: An In Vivo Cone-Beam Computed Tomography Study Quality of Life After Orthognathic Surgery in Swedish Patients: A Register-Based Cohort
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1