首次非接触式毫米波雷达测量类人猿的心率:黑猩猩(Pan troglodytes)的验证。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2024-05-22 DOI:10.1002/ajp.23633
Takuya Matsumoto, Itsuki Iwata, Takuya Sakamoto, Satoshi Hirata
{"title":"首次非接触式毫米波雷达测量类人猿的心率:黑猩猩(Pan troglodytes)的验证。","authors":"Takuya Matsumoto,&nbsp;Itsuki Iwata,&nbsp;Takuya Sakamoto,&nbsp;Satoshi Hirata","doi":"10.1002/ajp.23633","DOIUrl":null,"url":null,"abstract":"<p>Heart rate is a crucial vital sign and a valuable indicator for assessing the physical and psychological condition of a target animal. Heart rate contributes to (1) fundamental information for cognitive research, (2) an indicator of psychological and physical stress, and (3) improving the animal welfare of captive animals, especially in nonhuman primate studies. Heart rate has been measured using a contact-type device; however, the device burdens the target animals and that there are risks associated with anesthesia during installation. This study explores the application of heartbeat measurement techniques using millimeter-wave radar, primarily developed for humans, as a remote and noninvasive method for measuring the heart rate of nonhuman primates. Through a measurement test conducted on two chimpanzees, we observed a remarkable correspondence between the peak frequency spectrum of heart rate estimated using millimeter-wave radar and the mean value obtained from electrocardiograph data, thereby validating the accuracy of the method. To the best of our knowledge, this is the first demonstration of the precise measurement of great apes' heart rate using millimeter-wave radar technology. Compared to heart rate measurement using video analysis, the method using millimeter-wave radar has the advantage that it is less susceptible to weather and lighting conditions and that measurement techniques for multiple individuals have been developed for human subjects, while its disadvantage is that validation of measurement from long distances has not been completed. Another disadvantage common to both methods is that measurement becomes difficult when the movement of the target individual is large. The possibility of noncontact measurement of heart rate in wild and captive primates will undoubtedly open up a new research area while taking animal welfare into consideration.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/ajp.23633","citationCount":"0","resultStr":"{\"title\":\"First noncontact millimeter-wave radar measurement of heart rate in great apes: Validation in chimpanzees (Pan troglodytes)\",\"authors\":\"Takuya Matsumoto,&nbsp;Itsuki Iwata,&nbsp;Takuya Sakamoto,&nbsp;Satoshi Hirata\",\"doi\":\"10.1002/ajp.23633\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Heart rate is a crucial vital sign and a valuable indicator for assessing the physical and psychological condition of a target animal. Heart rate contributes to (1) fundamental information for cognitive research, (2) an indicator of psychological and physical stress, and (3) improving the animal welfare of captive animals, especially in nonhuman primate studies. Heart rate has been measured using a contact-type device; however, the device burdens the target animals and that there are risks associated with anesthesia during installation. This study explores the application of heartbeat measurement techniques using millimeter-wave radar, primarily developed for humans, as a remote and noninvasive method for measuring the heart rate of nonhuman primates. Through a measurement test conducted on two chimpanzees, we observed a remarkable correspondence between the peak frequency spectrum of heart rate estimated using millimeter-wave radar and the mean value obtained from electrocardiograph data, thereby validating the accuracy of the method. To the best of our knowledge, this is the first demonstration of the precise measurement of great apes' heart rate using millimeter-wave radar technology. Compared to heart rate measurement using video analysis, the method using millimeter-wave radar has the advantage that it is less susceptible to weather and lighting conditions and that measurement techniques for multiple individuals have been developed for human subjects, while its disadvantage is that validation of measurement from long distances has not been completed. Another disadvantage common to both methods is that measurement becomes difficult when the movement of the target individual is large. The possibility of noncontact measurement of heart rate in wild and captive primates will undoubtedly open up a new research area while taking animal welfare into consideration.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/ajp.23633\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/ajp.23633\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"99","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ajp.23633","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

心率是一种重要的生命体征,也是评估目标动物生理和心理状况的重要指标。心率有助于:(1) 认知研究的基本信息;(2) 心理和生理压力指标;(3) 改善圈养动物的动物福利,尤其是在非人灵长类研究中。心率测量一直使用接触式装置,但该装置会对目标动物造成负担,而且在安装过程中存在麻醉风险。本研究利用主要为人类开发的毫米波雷达来探索心跳测量技术的应用,以此作为测量非人灵长类动物心率的一种远程无创方法。通过对两只黑猩猩进行测量测试,我们观察到使用毫米波雷达估测的心率峰值频谱与心电图数据获得的平均值之间存在显著的对应关系,从而验证了该方法的准确性。据我们所知,这是首次利用毫米波雷达技术精确测量类人猿的心率。与利用视频分析测量心率的方法相比,利用毫米波雷达测量心率的方法的优点是不易受天气和光照条件的影响,而且已经开发出针对人类受试者的多个体测量技术,缺点是尚未完成远距离测量的验证。这两种方法的另一个共同缺点是,当目标个体移动幅度较大时,测量会变得困难。对野生和圈养灵长类动物进行非接触式心率测量无疑将开辟一个新的研究领域,同时也会考虑到动物福利问题。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
First noncontact millimeter-wave radar measurement of heart rate in great apes: Validation in chimpanzees (Pan troglodytes)

Heart rate is a crucial vital sign and a valuable indicator for assessing the physical and psychological condition of a target animal. Heart rate contributes to (1) fundamental information for cognitive research, (2) an indicator of psychological and physical stress, and (3) improving the animal welfare of captive animals, especially in nonhuman primate studies. Heart rate has been measured using a contact-type device; however, the device burdens the target animals and that there are risks associated with anesthesia during installation. This study explores the application of heartbeat measurement techniques using millimeter-wave radar, primarily developed for humans, as a remote and noninvasive method for measuring the heart rate of nonhuman primates. Through a measurement test conducted on two chimpanzees, we observed a remarkable correspondence between the peak frequency spectrum of heart rate estimated using millimeter-wave radar and the mean value obtained from electrocardiograph data, thereby validating the accuracy of the method. To the best of our knowledge, this is the first demonstration of the precise measurement of great apes' heart rate using millimeter-wave radar technology. Compared to heart rate measurement using video analysis, the method using millimeter-wave radar has the advantage that it is less susceptible to weather and lighting conditions and that measurement techniques for multiple individuals have been developed for human subjects, while its disadvantage is that validation of measurement from long distances has not been completed. Another disadvantage common to both methods is that measurement becomes difficult when the movement of the target individual is large. The possibility of noncontact measurement of heart rate in wild and captive primates will undoubtedly open up a new research area while taking animal welfare into consideration.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1