肺活量保留患者可变阻塞的临床特征和 1 年疗效:中国 ECOPD 研究结果。

IF 3.6 3区 医学 Q1 RESPIRATORY SYSTEM BMJ Open Respiratory Research Pub Date : 2024-05-24 DOI:10.1136/bmjresp-2023-002210
Fan Wu, Haiqing Li, Zhishan Deng, Huajing Yang, Youlan Zheng, Ningning Zhao, Cuiqiong Dai, Jieqi Peng, Lifei Lu, Zihui Wang, Xiang Wen, Shan Xiao, Kunning Zhou, Xiaohui Wu, Gaoying Tang, Qi Wan, Ruiting Sun, Jiangyu Cui, Changli Yang, Shengtang Chen, Jianhui Huang, Shuqing Yu, Yumin Zhou, Pixin Ran
{"title":"肺活量保留患者可变阻塞的临床特征和 1 年疗效:中国 ECOPD 研究结果。","authors":"Fan Wu, Haiqing Li, Zhishan Deng, Huajing Yang, Youlan Zheng, Ningning Zhao, Cuiqiong Dai, Jieqi Peng, Lifei Lu, Zihui Wang, Xiang Wen, Shan Xiao, Kunning Zhou, Xiaohui Wu, Gaoying Tang, Qi Wan, Ruiting Sun, Jiangyu Cui, Changli Yang, Shengtang Chen, Jianhui Huang, Shuqing Yu, Yumin Zhou, Pixin Ran","doi":"10.1136/bmjresp-2023-002210","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>There are limited data on the clinical features and longitudinal prognosis of variable obstruction, particularly among never smokers and different variable obstruction types. Therefore, we aimed to evaluate the clinical characteristics of the participants with variable obstruction and determine the relationship between variable obstruction and the development of chronic obstructive pulmonary disease (COPD) and the decline of lung function in a community-dwelling study of Chinese, especially among never smokers and different variable obstruction subtypes.</p><p><strong>Methods: </strong>Participants with preserved spirometry (postbronchodilator forced expiratory volume in 1 s (FEV<sub>1</sub>)/forced vital capacity (FVC) ≥0.70) at baseline from the Early COPD cohort were included in our analysis. Participants with variable obstruction (prebronchodilator FEV<sub>1</sub>/FVC <0.70) were compared with those without variable obstruction (prebronchodilator FEV<sub>1</sub>/FVC ≥0.70). We performed subgroup analyses in never smokers, former and current smokers, and different variable obstruction types (postbronchodilator FVC <prebronchodilator FVC or postbronchodilator FVC ≥prebronchodilator FVC).</p><p><strong>Results: </strong>The final analysis included 1140 participants with preserved spirometry (169 in the variable obstruction group) at baseline. Participants with variable obstruction were older, had lower lung function and had greater severe emphysema and computed tomography-defined air trapping than participants without variable obstruction. Participants with variable obstruction had a significantly increased risk of incident spirometry-defined COPD (relative risk: 3.22, 95% confidence interval 2.23 to 4.64, p <0.001) than those without variable obstruction after adjustment for covariates. These findings remained consistent among both former and current smokers, never smokers, and different variable obstruction types. Additionally, participants with variable obstruction had a faster decline in postbronchodilator FEV<sub>1</sub>/FVC (2.3±0.5%/year vs 0.9±0.4%/year, mean difference: 1.4 (95% confidence interval 0.5 to 2.3), p=0.002) than participants without variable obstruction after adjustment for covariates.</p><p><strong>Conclusions: </strong>The results of our study revealed that variable obstruction can identify individuals who are at risk for the development of COPD and accelerated postbronchodilator FEV<sub>1</sub>/FVC decline in preserved spirometry.</p>","PeriodicalId":9048,"journal":{"name":"BMJ Open Respiratory Research","volume":"11 1","pages":""},"PeriodicalIF":3.6000,"publicationDate":"2024-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11129023/pdf/","citationCount":"0","resultStr":"{\"title\":\"Clinical features and 1-year outcomes of variable obstruction in participants with preserved spirometry: results from the ECOPD study in China.\",\"authors\":\"Fan Wu, Haiqing Li, Zhishan Deng, Huajing Yang, Youlan Zheng, Ningning Zhao, Cuiqiong Dai, Jieqi Peng, Lifei Lu, Zihui Wang, Xiang Wen, Shan Xiao, Kunning Zhou, Xiaohui Wu, Gaoying Tang, Qi Wan, Ruiting Sun, Jiangyu Cui, Changli Yang, Shengtang Chen, Jianhui Huang, Shuqing Yu, Yumin Zhou, Pixin Ran\",\"doi\":\"10.1136/bmjresp-2023-002210\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>There are limited data on the clinical features and longitudinal prognosis of variable obstruction, particularly among never smokers and different variable obstruction types. Therefore, we aimed to evaluate the clinical characteristics of the participants with variable obstruction and determine the relationship between variable obstruction and the development of chronic obstructive pulmonary disease (COPD) and the decline of lung function in a community-dwelling study of Chinese, especially among never smokers and different variable obstruction subtypes.</p><p><strong>Methods: </strong>Participants with preserved spirometry (postbronchodilator forced expiratory volume in 1 s (FEV<sub>1</sub>)/forced vital capacity (FVC) ≥0.70) at baseline from the Early COPD cohort were included in our analysis. Participants with variable obstruction (prebronchodilator FEV<sub>1</sub>/FVC <0.70) were compared with those without variable obstruction (prebronchodilator FEV<sub>1</sub>/FVC ≥0.70). We performed subgroup analyses in never smokers, former and current smokers, and different variable obstruction types (postbronchodilator FVC <prebronchodilator FVC or postbronchodilator FVC ≥prebronchodilator FVC).</p><p><strong>Results: </strong>The final analysis included 1140 participants with preserved spirometry (169 in the variable obstruction group) at baseline. Participants with variable obstruction were older, had lower lung function and had greater severe emphysema and computed tomography-defined air trapping than participants without variable obstruction. Participants with variable obstruction had a significantly increased risk of incident spirometry-defined COPD (relative risk: 3.22, 95% confidence interval 2.23 to 4.64, p <0.001) than those without variable obstruction after adjustment for covariates. These findings remained consistent among both former and current smokers, never smokers, and different variable obstruction types. Additionally, participants with variable obstruction had a faster decline in postbronchodilator FEV<sub>1</sub>/FVC (2.3±0.5%/year vs 0.9±0.4%/year, mean difference: 1.4 (95% confidence interval 0.5 to 2.3), p=0.002) than participants without variable obstruction after adjustment for covariates.</p><p><strong>Conclusions: </strong>The results of our study revealed that variable obstruction can identify individuals who are at risk for the development of COPD and accelerated postbronchodilator FEV<sub>1</sub>/FVC decline in preserved spirometry.</p>\",\"PeriodicalId\":9048,\"journal\":{\"name\":\"BMJ Open Respiratory Research\",\"volume\":\"11 1\",\"pages\":\"\"},\"PeriodicalIF\":3.6000,\"publicationDate\":\"2024-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11129023/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BMJ Open Respiratory Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1136/bmjresp-2023-002210\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"RESPIRATORY SYSTEM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMJ Open Respiratory Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/bmjresp-2023-002210","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RESPIRATORY SYSTEM","Score":null,"Total":0}
引用次数: 0

摘要

背景:关于可变阻塞的临床特征和纵向预后的数据有限,尤其是在从不吸烟者和不同可变阻塞类型中。因此,我们旨在评估变异性阻塞参与者的临床特征,并确定变异性阻塞与慢性阻塞性肺病(COPD)的发展和肺功能下降之间的关系:早期慢性阻塞性肺病队列中基线肺活量保留(支气管扩张剂后 1 秒用力呼气容积(FEV1)/用力肺活量(FVC)≥0.70)的参与者被纳入我们的分析。存在可变阻塞的参与者(支气管舒张前 FEV1/FVC 1/FVC ≥0.70)。我们对从未吸烟者、曾经吸烟者和目前吸烟者以及不同的可变阻塞类型(支气管舒张后 FVC 结果)进行了分组分析:最终分析包括 1140 名基线肺活量保留的参与者(169 人属于可变阻塞组)。与无可变阻塞的参与者相比,有可变阻塞的参与者年龄更大,肺功能更低,严重肺气肿和计算机断层扫描定义的空气潴留更严重。存在可变阻塞的参与者发生肺活量测定定义的慢性阻塞性肺疾病的风险明显增加(相对风险:3.22,95% 置信区间为 2.23 至 4.64,p 1/FVC(2.3±0.5%/年 vs 0.9±0.4%/年,平均差异:1.4(95% 置信区间:1.4)):结论:我们的研究结果表明,可变阻塞可识别出慢性阻塞性肺病的高危人群,并可在保留肺活量的情况下加速支气管扩张剂后 FEV1/FVC 的下降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Clinical features and 1-year outcomes of variable obstruction in participants with preserved spirometry: results from the ECOPD study in China.

Background: There are limited data on the clinical features and longitudinal prognosis of variable obstruction, particularly among never smokers and different variable obstruction types. Therefore, we aimed to evaluate the clinical characteristics of the participants with variable obstruction and determine the relationship between variable obstruction and the development of chronic obstructive pulmonary disease (COPD) and the decline of lung function in a community-dwelling study of Chinese, especially among never smokers and different variable obstruction subtypes.

Methods: Participants with preserved spirometry (postbronchodilator forced expiratory volume in 1 s (FEV1)/forced vital capacity (FVC) ≥0.70) at baseline from the Early COPD cohort were included in our analysis. Participants with variable obstruction (prebronchodilator FEV1/FVC <0.70) were compared with those without variable obstruction (prebronchodilator FEV1/FVC ≥0.70). We performed subgroup analyses in never smokers, former and current smokers, and different variable obstruction types (postbronchodilator FVC

Results: The final analysis included 1140 participants with preserved spirometry (169 in the variable obstruction group) at baseline. Participants with variable obstruction were older, had lower lung function and had greater severe emphysema and computed tomography-defined air trapping than participants without variable obstruction. Participants with variable obstruction had a significantly increased risk of incident spirometry-defined COPD (relative risk: 3.22, 95% confidence interval 2.23 to 4.64, p <0.001) than those without variable obstruction after adjustment for covariates. These findings remained consistent among both former and current smokers, never smokers, and different variable obstruction types. Additionally, participants with variable obstruction had a faster decline in postbronchodilator FEV1/FVC (2.3±0.5%/year vs 0.9±0.4%/year, mean difference: 1.4 (95% confidence interval 0.5 to 2.3), p=0.002) than participants without variable obstruction after adjustment for covariates.

Conclusions: The results of our study revealed that variable obstruction can identify individuals who are at risk for the development of COPD and accelerated postbronchodilator FEV1/FVC decline in preserved spirometry.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BMJ Open Respiratory Research
BMJ Open Respiratory Research RESPIRATORY SYSTEM-
CiteScore
6.60
自引率
2.40%
发文量
95
审稿时长
12 weeks
期刊介绍: BMJ Open Respiratory Research is a peer-reviewed, open access journal publishing respiratory and critical care medicine. It is the sister journal to Thorax and co-owned by the British Thoracic Society and BMJ. The journal focuses on robustness of methodology and scientific rigour with less emphasis on novelty or perceived impact. BMJ Open Respiratory Research operates a rapid review process, with continuous publication online, ensuring timely, up-to-date research is available worldwide. The journal publishes review articles and all research study types: Basic science including laboratory based experiments and animal models, Pilot studies or proof of concept, Observational studies, Study protocols, Registries, Clinical trials from phase I to multicentre randomised clinical trials, Systematic reviews and meta-analyses.
期刊最新文献
Trends of mortality from chronic respiratory diseases by sex and ethnicity in the USA: a secular analysis from 1979 to 2021 using data from death certificates. Firefighters' occupational exposure to air pollution: impact on COPD and asthma-study protocol. Risk factors for incidence of interstitial lung disease in patients with rheumatoid arthritis: a systematic review and meta-analysis. Pleural effusion in acute pulmonary embolism: characteristics and relevance. Pim1 inactivating induces RUNX3 upregulation that improves/alleviates airway inflammation and mucus hypersecretion in vitro and in vivo.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1