{"title":"在牙齿自动移植过程中,计算机辅助手术规划与实际牙齿位置之间的准确性评估。","authors":"Jiaming Zhang, Yue Han, Haoyan Zhong","doi":"10.1111/edt.12971","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/aim: </strong>This study aims to evaluate the precision and efficacy of utilizing computer-aided design (CAD) in combination with three-dimensional printing technology for tooth transplantation.</p><p><strong>Material and methods: </strong>This study analysed 50 transplanted teeth from 48 patients who underwent tooth transplantation surgery with the aid of CAD and positional guides. A consistent coordinate system was established using preoperative and postoperative cone-beam computed tomography images. Linear displacements and angular deviations were calculated by identifying key regions in both virtual designs and actual transplanted teeth. Additionally, an analysis was conducted to explore potential factors influencing these deviations.</p><p><strong>Results: </strong>The mean cervical deviation, apical deviation, and angular deviation among the 50 transplanted teeth were 1.16 ± 0.57 mm, 1.80 ± 0.94 mm, and 6.82 ± 3.14°, respectively. Cervical deviation was significantly smaller than apical deviation. No significant difference in deviation was observed among different recipient socket locations, holding true for both single-root, and multi-root teeth. However, a significant difference was noted in apical deviation between single-root and multi-root teeth. Our analysis identified a correlation between apical deviation and root length, leading to the development of a prediction model: Apical deviation = 0.1390 × (root length) + 0.2791.</p><p><strong>Conclusions: </strong>The postoperative position of the donor teeth shows discrepancies compared to preoperative simulation when utilizing CAD and 3D printed templates during autotransplantation procedures. Continual refinement of preoperative design is a crucial endeavour.</p>","PeriodicalId":55180,"journal":{"name":"Dental Traumatology","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Accuracy assessment between computer-guided surgery planning and actual tooth position during tooth autotransplantation.\",\"authors\":\"Jiaming Zhang, Yue Han, Haoyan Zhong\",\"doi\":\"10.1111/edt.12971\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background/aim: </strong>This study aims to evaluate the precision and efficacy of utilizing computer-aided design (CAD) in combination with three-dimensional printing technology for tooth transplantation.</p><p><strong>Material and methods: </strong>This study analysed 50 transplanted teeth from 48 patients who underwent tooth transplantation surgery with the aid of CAD and positional guides. A consistent coordinate system was established using preoperative and postoperative cone-beam computed tomography images. Linear displacements and angular deviations were calculated by identifying key regions in both virtual designs and actual transplanted teeth. Additionally, an analysis was conducted to explore potential factors influencing these deviations.</p><p><strong>Results: </strong>The mean cervical deviation, apical deviation, and angular deviation among the 50 transplanted teeth were 1.16 ± 0.57 mm, 1.80 ± 0.94 mm, and 6.82 ± 3.14°, respectively. Cervical deviation was significantly smaller than apical deviation. No significant difference in deviation was observed among different recipient socket locations, holding true for both single-root, and multi-root teeth. However, a significant difference was noted in apical deviation between single-root and multi-root teeth. Our analysis identified a correlation between apical deviation and root length, leading to the development of a prediction model: Apical deviation = 0.1390 × (root length) + 0.2791.</p><p><strong>Conclusions: </strong>The postoperative position of the donor teeth shows discrepancies compared to preoperative simulation when utilizing CAD and 3D printed templates during autotransplantation procedures. Continual refinement of preoperative design is a crucial endeavour.</p>\",\"PeriodicalId\":55180,\"journal\":{\"name\":\"Dental Traumatology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dental Traumatology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/edt.12971\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/5/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Traumatology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/edt.12971","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/5/25 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

背景/目的:本研究旨在评估利用计算机辅助设计(CAD)结合三维打印技术进行牙齿移植的精确性和有效性:本研究分析了 48 名患者的 50 颗移植牙齿,这些患者在计算机辅助设计和定位指南的帮助下接受了牙齿移植手术。利用术前和术后锥形束计算机断层扫描图像建立了一致的坐标系统。通过识别虚拟设计和实际移植牙齿的关键区域,计算出线性位移和角度偏差。此外,还对影响这些偏差的潜在因素进行了分析:结果:50 颗移植牙齿的平均颈椎偏差、根尖偏差和角度偏差分别为 1.16 ± 0.57 mm、1.80 ± 0.94 mm 和 6.82 ± 3.14°。牙颈部偏差明显小于根尖偏差。单根牙和多根牙的不同受托窝洞位置之间的偏差没有明显差异。但是,单根牙和多根牙的根尖偏差有明显差异。我们的分析确定了根尖偏差与牙根长度之间的相关性,从而建立了一个预测模型:根尖偏差 = 0.1390 ×(牙根长度)+ 0.2791:在自体牙移植手术中使用 CAD 和 3D 打印模板时,供体牙齿的术后位置与术前模拟相比存在差异。不断完善术前设计是一项至关重要的工作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Accuracy assessment between computer-guided surgery planning and actual tooth position during tooth autotransplantation.

Background/aim: This study aims to evaluate the precision and efficacy of utilizing computer-aided design (CAD) in combination with three-dimensional printing technology for tooth transplantation.

Material and methods: This study analysed 50 transplanted teeth from 48 patients who underwent tooth transplantation surgery with the aid of CAD and positional guides. A consistent coordinate system was established using preoperative and postoperative cone-beam computed tomography images. Linear displacements and angular deviations were calculated by identifying key regions in both virtual designs and actual transplanted teeth. Additionally, an analysis was conducted to explore potential factors influencing these deviations.

Results: The mean cervical deviation, apical deviation, and angular deviation among the 50 transplanted teeth were 1.16 ± 0.57 mm, 1.80 ± 0.94 mm, and 6.82 ± 3.14°, respectively. Cervical deviation was significantly smaller than apical deviation. No significant difference in deviation was observed among different recipient socket locations, holding true for both single-root, and multi-root teeth. However, a significant difference was noted in apical deviation between single-root and multi-root teeth. Our analysis identified a correlation between apical deviation and root length, leading to the development of a prediction model: Apical deviation = 0.1390 × (root length) + 0.2791.

Conclusions: The postoperative position of the donor teeth shows discrepancies compared to preoperative simulation when utilizing CAD and 3D printed templates during autotransplantation procedures. Continual refinement of preoperative design is a crucial endeavour.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Dental Traumatology
Dental Traumatology 医学-牙科与口腔外科
CiteScore
6.40
自引率
32.00%
发文量
85
审稿时长
6-12 weeks
期刊介绍: Dental Traumatology is an international journal that aims to convey scientific and clinical progress in all areas related to adult and pediatric dental traumatology. This includes the following topics: - Epidemiology, Social Aspects, Education, Diagnostics - Esthetics / Prosthetics/ Restorative - Evidence Based Traumatology & Study Design - Oral & Maxillofacial Surgery/Transplant/Implant - Pediatrics and Orthodontics - Prevention and Sports Dentistry - Endodontics and Periodontal Aspects The journal"s aim is to promote communication among clinicians, educators, researchers, and others interested in the field of dental traumatology.
期刊最新文献
Assessment of artificial intelligence applications in responding to dental trauma. Public health policies in dental traumatology: A call for action! Reliability of information in YouTube™ videos on types of root resorption and related stimulating factors. Accuracy assessment between computer-guided surgery planning and actual tooth position during tooth autotransplantation. Comparison of shock absorption capacities of three types of mouthguards: A comparative in vitro study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1