Hemmo A. F. Yska, Bela R. Turk, Ali Fatemi, Jordan Goodman, Marije Voermans, Dan Amos, Man Amanat, Stephanie van de Stadt, Marc Engelen, Amena Smith-Fine, Jennifer Keller
{"title":"对评估肾上腺白质营养不良症成人骨髓神经病的姿势摇摆和步态的意义进行国际验证。","authors":"Hemmo A. F. Yska, Bela R. Turk, Ali Fatemi, Jordan Goodman, Marije Voermans, Dan Amos, Man Amanat, Stephanie van de Stadt, Marc Engelen, Amena Smith-Fine, Jennifer Keller","doi":"10.1002/jimd.12753","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>The most common manifestation of X-linked adrenoleukodystrophy (ALD) is a slowly progressive myeloneuropathy, which leads to imbalance and gait disturbances. The variable progression of the disease complicates evaluation of its progression rate. Wearable sensors allow for easy and frequent balance and gait collection. This study reports baseline data from a longitudinal study on the quantitative assessment of balance and gait with wearable sensors and their clinical relevance.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>Data were collected from adult patients in two institutions. Postural body sway and gait parameters were measured using accelerometers. Disease severity was measured by the Expanded Disability Severity Scale (EDSS). Falling frequency and quality of life (QOL) were collected in men. The relationship between sway and gait variables and EDSS score, participants' use of a walking aid, and falling frequency was evaluated.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>One hundred twenty individuals with ALD were included. Sway variables significantly differentiate participants' assistive device use. Sway and gait variables were correlated to the EDSS in both sexes. Both gait speed and sway were correlated with falling frequency in men from one institution. Select QOL subscores were correlated with the EDSS in males from one institution. Accelerometry generated comparable results across sites.</p>\n </section>\n \n <section>\n \n <h3> Discussion</h3>\n \n <p>This study confirms the clinical correlation between spinal cord disease and imbalance and gait in ALD. For the first time, this study shows clinically meaningful relationships for sway and gait with use of an assistive device, falling frequency and QOL. Wearable accelerometers are a valid means to measure sway and gait in ALD. These measures are promising outcomes for clinical trial designs to assess myeloneuropathy in ALD and to monitor disease progression in individuals.</p>\n </section>\n </div>","PeriodicalId":16281,"journal":{"name":"Journal of Inherited Metabolic Disease","volume":"47 6","pages":"1336-1347"},"PeriodicalIF":4.2000,"publicationDate":"2024-05-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jimd.12753","citationCount":"0","resultStr":"{\"title\":\"International validation of meaningfulness of postural sway and gait to assess myeloneuropathy in adults with adrenoleukodystrophy\",\"authors\":\"Hemmo A. F. Yska, Bela R. Turk, Ali Fatemi, Jordan Goodman, Marije Voermans, Dan Amos, Man Amanat, Stephanie van de Stadt, Marc Engelen, Amena Smith-Fine, Jennifer Keller\",\"doi\":\"10.1002/jimd.12753\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>The most common manifestation of X-linked adrenoleukodystrophy (ALD) is a slowly progressive myeloneuropathy, which leads to imbalance and gait disturbances. The variable progression of the disease complicates evaluation of its progression rate. Wearable sensors allow for easy and frequent balance and gait collection. This study reports baseline data from a longitudinal study on the quantitative assessment of balance and gait with wearable sensors and their clinical relevance.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>Data were collected from adult patients in two institutions. Postural body sway and gait parameters were measured using accelerometers. Disease severity was measured by the Expanded Disability Severity Scale (EDSS). Falling frequency and quality of life (QOL) were collected in men. The relationship between sway and gait variables and EDSS score, participants' use of a walking aid, and falling frequency was evaluated.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>One hundred twenty individuals with ALD were included. Sway variables significantly differentiate participants' assistive device use. Sway and gait variables were correlated to the EDSS in both sexes. Both gait speed and sway were correlated with falling frequency in men from one institution. Select QOL subscores were correlated with the EDSS in males from one institution. Accelerometry generated comparable results across sites.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Discussion</h3>\\n \\n <p>This study confirms the clinical correlation between spinal cord disease and imbalance and gait in ALD. For the first time, this study shows clinically meaningful relationships for sway and gait with use of an assistive device, falling frequency and QOL. Wearable accelerometers are a valid means to measure sway and gait in ALD. These measures are promising outcomes for clinical trial designs to assess myeloneuropathy in ALD and to monitor disease progression in individuals.</p>\\n </section>\\n </div>\",\"PeriodicalId\":16281,\"journal\":{\"name\":\"Journal of Inherited Metabolic Disease\",\"volume\":\"47 6\",\"pages\":\"1336-1347\"},\"PeriodicalIF\":4.2000,\"publicationDate\":\"2024-05-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jimd.12753\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Inherited Metabolic Disease\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jimd.12753\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENDOCRINOLOGY & METABOLISM\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Inherited Metabolic Disease","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jimd.12753","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENDOCRINOLOGY & METABOLISM","Score":null,"Total":0}
International validation of meaningfulness of postural sway and gait to assess myeloneuropathy in adults with adrenoleukodystrophy
Background
The most common manifestation of X-linked adrenoleukodystrophy (ALD) is a slowly progressive myeloneuropathy, which leads to imbalance and gait disturbances. The variable progression of the disease complicates evaluation of its progression rate. Wearable sensors allow for easy and frequent balance and gait collection. This study reports baseline data from a longitudinal study on the quantitative assessment of balance and gait with wearable sensors and their clinical relevance.
Methods
Data were collected from adult patients in two institutions. Postural body sway and gait parameters were measured using accelerometers. Disease severity was measured by the Expanded Disability Severity Scale (EDSS). Falling frequency and quality of life (QOL) were collected in men. The relationship between sway and gait variables and EDSS score, participants' use of a walking aid, and falling frequency was evaluated.
Results
One hundred twenty individuals with ALD were included. Sway variables significantly differentiate participants' assistive device use. Sway and gait variables were correlated to the EDSS in both sexes. Both gait speed and sway were correlated with falling frequency in men from one institution. Select QOL subscores were correlated with the EDSS in males from one institution. Accelerometry generated comparable results across sites.
Discussion
This study confirms the clinical correlation between spinal cord disease and imbalance and gait in ALD. For the first time, this study shows clinically meaningful relationships for sway and gait with use of an assistive device, falling frequency and QOL. Wearable accelerometers are a valid means to measure sway and gait in ALD. These measures are promising outcomes for clinical trial designs to assess myeloneuropathy in ALD and to monitor disease progression in individuals.
期刊介绍:
The Journal of Inherited Metabolic Disease (JIMD) is the official journal of the Society for the Study of Inborn Errors of Metabolism (SSIEM). By enhancing communication between workers in the field throughout the world, the JIMD aims to improve the management and understanding of inherited metabolic disorders. It publishes results of original research and new or important observations pertaining to any aspect of inherited metabolic disease in humans and higher animals. This includes clinical (medical, dental and veterinary), biochemical, genetic (including cytogenetic, molecular and population genetic), experimental (including cell biological), methodological, theoretical, epidemiological, ethical and counselling aspects. The JIMD also reviews important new developments or controversial issues relating to metabolic disorders and publishes reviews and short reports arising from the Society''s annual symposia. A distinction is made between peer-reviewed scientific material that is selected because of its significance for other professionals in the field and non-peer- reviewed material that aims to be important, controversial, interesting or entertaining (“Extras”).