用于 CMC 显微计算机断层扫描实验的深度学习驱动型快速扫描方法

IF 2 3区 工程技术 Q2 MATERIALS SCIENCE, CHARACTERIZATION & TESTING Experimental Mechanics Pub Date : 2024-05-24 DOI:10.1007/s11340-024-01081-x
R.Q. Zhu, G.H. Niu, Z.L. Qu, P.D. Wang, D.N. Fang
{"title":"用于 CMC 显微计算机断层扫描实验的深度学习驱动型快速扫描方法","authors":"R.Q. Zhu,&nbsp;G.H. Niu,&nbsp;Z.L. Qu,&nbsp;P.D. Wang,&nbsp;D.N. Fang","doi":"10.1007/s11340-024-01081-x","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p><i>In-situ</i> micro-computed tomography (µCT) technology is an attractive approach to investigate the evolution process of damage inside ceramic matrix composites (CMCs) during high-temperature service. The evolution process is highly time-sensitive under temperature-induced loads, and fast scanning is very necessary for <i>in-situ</i> µCT tests.</p><h3>Objective</h3><p>The objective of this work is to provide a fast scanning method for in situ µCT tests on CMCs with complex microstructures by the innovation of a reconstruction algorithm.</p><h3>Method</h3><p>To overcome the severe degradation of the reconstructed image quality resulting from sparse CT scans, a deep-learning-based multi-domain sparse reconstruction method was proposed. Three sub-networks including the projection-domain, image-domain, and fusion network were constructed in the multi-domain method to make full use of the information from the projection and image domain.</p><h3>Results</h3><p>The proposed deep-learning-based sparse reconstruction method provided satisfactory µCT images on C/SiC composites with acceptable quality. The scanning time was reduced by 6 times. All selected evaluation metrics of the proposed method are higher than those of other single-domain methods and traditional iterative method. The segmentation accuracy of the µCT images obtained by the proposed method can meet the subsequent quantitative analysis. An <i>in-situ</i> tensile test of CMCs is conducted to further evaluate the performance in the practical application of <i>in-situ</i> experiments. The results indicate that the weak and thin micro-cracks can still be effectively retained and recovered. A detailed workflow to implement the method generally is also provided.</p><h3>Conclusions</h3><p>Based on the deep-learning-based multi-domain sparse reconstruction method, the process of <i>in-situ</i> µCT tests can be greatly accelerated with little loss of the reconstructed image quality.</p></div>","PeriodicalId":552,"journal":{"name":"Experimental Mechanics","volume":"64 7","pages":"1053 - 1072"},"PeriodicalIF":2.0000,"publicationDate":"2024-05-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Deep Learning-Driven Fast Scanning Method for Micro-Computed Tomography Experiments on CMCs\",\"authors\":\"R.Q. Zhu,&nbsp;G.H. Niu,&nbsp;Z.L. Qu,&nbsp;P.D. Wang,&nbsp;D.N. Fang\",\"doi\":\"10.1007/s11340-024-01081-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p><i>In-situ</i> micro-computed tomography (µCT) technology is an attractive approach to investigate the evolution process of damage inside ceramic matrix composites (CMCs) during high-temperature service. The evolution process is highly time-sensitive under temperature-induced loads, and fast scanning is very necessary for <i>in-situ</i> µCT tests.</p><h3>Objective</h3><p>The objective of this work is to provide a fast scanning method for in situ µCT tests on CMCs with complex microstructures by the innovation of a reconstruction algorithm.</p><h3>Method</h3><p>To overcome the severe degradation of the reconstructed image quality resulting from sparse CT scans, a deep-learning-based multi-domain sparse reconstruction method was proposed. Three sub-networks including the projection-domain, image-domain, and fusion network were constructed in the multi-domain method to make full use of the information from the projection and image domain.</p><h3>Results</h3><p>The proposed deep-learning-based sparse reconstruction method provided satisfactory µCT images on C/SiC composites with acceptable quality. The scanning time was reduced by 6 times. All selected evaluation metrics of the proposed method are higher than those of other single-domain methods and traditional iterative method. The segmentation accuracy of the µCT images obtained by the proposed method can meet the subsequent quantitative analysis. An <i>in-situ</i> tensile test of CMCs is conducted to further evaluate the performance in the practical application of <i>in-situ</i> experiments. The results indicate that the weak and thin micro-cracks can still be effectively retained and recovered. A detailed workflow to implement the method generally is also provided.</p><h3>Conclusions</h3><p>Based on the deep-learning-based multi-domain sparse reconstruction method, the process of <i>in-situ</i> µCT tests can be greatly accelerated with little loss of the reconstructed image quality.</p></div>\",\"PeriodicalId\":552,\"journal\":{\"name\":\"Experimental Mechanics\",\"volume\":\"64 7\",\"pages\":\"1053 - 1072\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-05-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Experimental Mechanics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s11340-024-01081-x\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, CHARACTERIZATION & TESTING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Experimental Mechanics","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s11340-024-01081-x","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
引用次数: 0

摘要

背景原位微计算机断层扫描(µCT)技术是研究高温服役期间陶瓷基复合材料(CMC)内部损伤演变过程的一种极具吸引力的方法。为了克服稀疏 CT 扫描导致的重建图像质量严重下降的问题,提出了一种基于深度学习的多域稀疏重建方法。结果基于深度学习的稀疏重建方法为 C/SiC 复合材料提供了令人满意的 µCT 图像,图像质量可以接受。扫描时间缩短了 6 倍。与其他单域方法和传统迭代法相比,所提方法的所有选定评价指标都更高。该方法获得的 µCT 图像的分割精度可以满足后续定量分析的需要。对 CMC 进行了原位拉伸试验,以进一步评估其在原位实验实际应用中的性能。结果表明,薄弱的微裂纹仍能有效保留和恢复。结论基于深度学习的多域稀疏重建方法可以大大加快原位 µCT 试验的进程,而重建图像的质量几乎没有损失。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Deep Learning-Driven Fast Scanning Method for Micro-Computed Tomography Experiments on CMCs

Background

In-situ micro-computed tomography (µCT) technology is an attractive approach to investigate the evolution process of damage inside ceramic matrix composites (CMCs) during high-temperature service. The evolution process is highly time-sensitive under temperature-induced loads, and fast scanning is very necessary for in-situ µCT tests.

Objective

The objective of this work is to provide a fast scanning method for in situ µCT tests on CMCs with complex microstructures by the innovation of a reconstruction algorithm.

Method

To overcome the severe degradation of the reconstructed image quality resulting from sparse CT scans, a deep-learning-based multi-domain sparse reconstruction method was proposed. Three sub-networks including the projection-domain, image-domain, and fusion network were constructed in the multi-domain method to make full use of the information from the projection and image domain.

Results

The proposed deep-learning-based sparse reconstruction method provided satisfactory µCT images on C/SiC composites with acceptable quality. The scanning time was reduced by 6 times. All selected evaluation metrics of the proposed method are higher than those of other single-domain methods and traditional iterative method. The segmentation accuracy of the µCT images obtained by the proposed method can meet the subsequent quantitative analysis. An in-situ tensile test of CMCs is conducted to further evaluate the performance in the practical application of in-situ experiments. The results indicate that the weak and thin micro-cracks can still be effectively retained and recovered. A detailed workflow to implement the method generally is also provided.

Conclusions

Based on the deep-learning-based multi-domain sparse reconstruction method, the process of in-situ µCT tests can be greatly accelerated with little loss of the reconstructed image quality.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Experimental Mechanics
Experimental Mechanics 物理-材料科学:表征与测试
CiteScore
4.40
自引率
16.70%
发文量
111
审稿时长
3 months
期刊介绍: Experimental Mechanics is the official journal of the Society for Experimental Mechanics that publishes papers in all areas of experimentation including its theoretical and computational analysis. The journal covers research in design and implementation of novel or improved experiments to characterize materials, structures and systems. Articles extending the frontiers of experimental mechanics at large and small scales are particularly welcome. Coverage extends from research in solid and fluids mechanics to fields at the intersection of disciplines including physics, chemistry and biology. Development of new devices and technologies for metrology applications in a wide range of industrial sectors (e.g., manufacturing, high-performance materials, aerospace, information technology, medicine, energy and environmental technologies) is also covered.
期刊最新文献
On the Cover: A Novel Method to In-Situ Characterize Fatigue Crack Growth Behavior of Nickel Based Superalloys by Laser Thermography Editorial: Message from the Incoming Editor-in-Chief Characterization of Environmental Stress Cracking in Polymers Through a Modified Bent Strip Test Method Evolving Properties of Biological Materials Captured via Needle-Based Cavity Expansion Method Study of Thermomechanical Behavior of Refractory Materials Under Thermal Gradient. Part I – Presentation of ATHORNA Device and Experimental Protocol
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1