Ahmad Khoshkhou, Moslem Shaabani, Enayatollah Bakhshi, Mohanna Javanbakht
{"title":"睡眠时是否可以像清醒时一样使用言语诱发听觉脑干反应测试?","authors":"Ahmad Khoshkhou, Moslem Shaabani, Enayatollah Bakhshi, Mohanna Javanbakht","doi":"10.18502/avr.v33i3.15503","DOIUrl":null,"url":null,"abstract":"Background and Aim: It is important to know how much are the auditory electrophysi- ological tests affected by sleep and wakefulness to be employed in different situations. This problem is more important for the speech-evoked Auditory Brainstem Response (speech- ABR) test that is affected by higher-level processing. This study aimed to compare the results of the speech-ABR test between wakefulness and sleep states. \nMethods: Sixteen young male adults (aged 20–28 years) with normal hearing participated in this study. The speech-ABR to the /da/ syllable was recorded during wakefulness and sleep. Electroencephalography (EEG) and behavioral tests (eyes position, body movements, etc.) were monitored during the test time to confirm the sleep state. \nResults: The speech-ABR test parameters showed significant changes during sleep compared to wakefulness (latencies of waves V and A were longer and the amplitudes of waves V and A, the slope of V-A complex, and the spectral magnitude of F1 were lower). However, the spectral magnitude of higher frequencies was not significantly different. In addition, no significant statistical difference was observed in speech-ABR parameters between right and left ears. \nConclusion: Although the speech-ABR originates from brainstem centers, unlike conventional click-evoked ABR, it is affected by sleep as it is affected by the higher-level auditory processing functions. Although, further studies are needed. However, our study opens the way for many applied auditory studies about the possibility to use speech-ABR for auditory processing assessments in sleep state of different population groups, such as neonates. \nKeywords: Auditory brainstem response; speech acoustics; sleep; electroencephalography \n ","PeriodicalId":34089,"journal":{"name":"Auditory and Vestibular Research","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2024-05-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Is It Possible to Use the Speech-Evoked Auditory Brainstem Response Test During Sleep as It Is Used During Wakefulness?\",\"authors\":\"Ahmad Khoshkhou, Moslem Shaabani, Enayatollah Bakhshi, Mohanna Javanbakht\",\"doi\":\"10.18502/avr.v33i3.15503\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background and Aim: It is important to know how much are the auditory electrophysi- ological tests affected by sleep and wakefulness to be employed in different situations. This problem is more important for the speech-evoked Auditory Brainstem Response (speech- ABR) test that is affected by higher-level processing. This study aimed to compare the results of the speech-ABR test between wakefulness and sleep states. \\nMethods: Sixteen young male adults (aged 20–28 years) with normal hearing participated in this study. The speech-ABR to the /da/ syllable was recorded during wakefulness and sleep. Electroencephalography (EEG) and behavioral tests (eyes position, body movements, etc.) were monitored during the test time to confirm the sleep state. \\nResults: The speech-ABR test parameters showed significant changes during sleep compared to wakefulness (latencies of waves V and A were longer and the amplitudes of waves V and A, the slope of V-A complex, and the spectral magnitude of F1 were lower). However, the spectral magnitude of higher frequencies was not significantly different. In addition, no significant statistical difference was observed in speech-ABR parameters between right and left ears. \\nConclusion: Although the speech-ABR originates from brainstem centers, unlike conventional click-evoked ABR, it is affected by sleep as it is affected by the higher-level auditory processing functions. Although, further studies are needed. However, our study opens the way for many applied auditory studies about the possibility to use speech-ABR for auditory processing assessments in sleep state of different population groups, such as neonates. \\nKeywords: Auditory brainstem response; speech acoustics; sleep; electroencephalography \\n \",\"PeriodicalId\":34089,\"journal\":{\"name\":\"Auditory and Vestibular Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2024-05-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Auditory and Vestibular Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18502/avr.v33i3.15503\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Auditory and Vestibular Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/avr.v33i3.15503","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
背景和目的:了解听觉电生理测试在不同情况下使用时受睡眠和清醒的影响程度非常重要。对于受高级处理影响的言语诱发听觉脑干反应(言语-ABR)测试来说,这个问题更为重要。本研究旨在比较清醒和睡眠状态下的言语-ABR测试结果。研究方法16 名听力正常的年轻男性(20-28 岁)参加了本研究。记录了清醒和睡眠状态下对/da/音节的言语-ABR测试结果。在测试期间监测脑电图(EEG)和行为测试(眼睛位置、身体运动等),以确认睡眠状态。结果与清醒状态相比,睡眠状态下的语音-ABR 测试参数发生了显著变化(V 波和 A 波的潜伏期延长,V 波和 A 波的振幅、V-A 复合波的斜率以及 F1 的频谱幅度降低)。然而,较高频率的频谱幅度没有显著差异。 此外,左右耳的语音-ABR 参数也没有明显的统计学差异。结论虽然语音-ABR 源自脑干中枢,但与传统的点击诱发 ABR 不同,它受到睡眠的影响,因为它受到高级听觉处理功能的影响。虽然还需要进一步研究。然而,我们的研究为许多听觉应用研究开辟了道路,使人们有可能使用语音-ABR 对不同人群(如新生儿)的睡眠状态进行听觉处理评估。关键词听性脑干反应;言语声学;睡眠;脑电图
Is It Possible to Use the Speech-Evoked Auditory Brainstem Response Test During Sleep as It Is Used During Wakefulness?
Background and Aim: It is important to know how much are the auditory electrophysi- ological tests affected by sleep and wakefulness to be employed in different situations. This problem is more important for the speech-evoked Auditory Brainstem Response (speech- ABR) test that is affected by higher-level processing. This study aimed to compare the results of the speech-ABR test between wakefulness and sleep states.
Methods: Sixteen young male adults (aged 20–28 years) with normal hearing participated in this study. The speech-ABR to the /da/ syllable was recorded during wakefulness and sleep. Electroencephalography (EEG) and behavioral tests (eyes position, body movements, etc.) were monitored during the test time to confirm the sleep state.
Results: The speech-ABR test parameters showed significant changes during sleep compared to wakefulness (latencies of waves V and A were longer and the amplitudes of waves V and A, the slope of V-A complex, and the spectral magnitude of F1 were lower). However, the spectral magnitude of higher frequencies was not significantly different. In addition, no significant statistical difference was observed in speech-ABR parameters between right and left ears.
Conclusion: Although the speech-ABR originates from brainstem centers, unlike conventional click-evoked ABR, it is affected by sleep as it is affected by the higher-level auditory processing functions. Although, further studies are needed. However, our study opens the way for many applied auditory studies about the possibility to use speech-ABR for auditory processing assessments in sleep state of different population groups, such as neonates.
Keywords: Auditory brainstem response; speech acoustics; sleep; electroencephalography