{"title":"优化视网膜下注射的生物力学考虑因素","authors":"","doi":"10.1016/j.survophthal.2024.05.004","DOIUrl":null,"url":null,"abstract":"<div><p>Subretinal injection is the preferred delivery technique for various novel ocular therapies and is widely used because of its precision and efficient delivery of gene and cell therapies; however, choosing an injection point and defining delivery parameters to target a specified retinal location and area is an inexact science. We provide an overview of the key factors that play important roles during subretinal injections to refine the technique, enhance patient outcomes, and minimise risks. We describe the role of anatomical and physical variables that affect subretinal bleb propagation and shape and their impact on retinal integrity. We highlight the risks associated with subretinal injections and consider strategies to mitigate reflux and retinal trauma. Finally, we explore the emerging field of robotic assistance in improving intraocular manouvrability and precision to facilitate the injection procedure.</p></div>","PeriodicalId":22102,"journal":{"name":"Survey of ophthalmology","volume":"69 5","pages":"Pages 722-732"},"PeriodicalIF":5.1000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0039625724000535/pdfft?md5=5cac6d4d6d97ada1eb0e53bb4743d819&pid=1-s2.0-S0039625724000535-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Biomechanical considerations for optimising subretinal injections\",\"authors\":\"\",\"doi\":\"10.1016/j.survophthal.2024.05.004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Subretinal injection is the preferred delivery technique for various novel ocular therapies and is widely used because of its precision and efficient delivery of gene and cell therapies; however, choosing an injection point and defining delivery parameters to target a specified retinal location and area is an inexact science. We provide an overview of the key factors that play important roles during subretinal injections to refine the technique, enhance patient outcomes, and minimise risks. We describe the role of anatomical and physical variables that affect subretinal bleb propagation and shape and their impact on retinal integrity. We highlight the risks associated with subretinal injections and consider strategies to mitigate reflux and retinal trauma. Finally, we explore the emerging field of robotic assistance in improving intraocular manouvrability and precision to facilitate the injection procedure.</p></div>\",\"PeriodicalId\":22102,\"journal\":{\"name\":\"Survey of ophthalmology\",\"volume\":\"69 5\",\"pages\":\"Pages 722-732\"},\"PeriodicalIF\":5.1000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S0039625724000535/pdfft?md5=5cac6d4d6d97ada1eb0e53bb4743d819&pid=1-s2.0-S0039625724000535-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Survey of ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0039625724000535\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Survey of ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0039625724000535","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Biomechanical considerations for optimising subretinal injections
Subretinal injection is the preferred delivery technique for various novel ocular therapies and is widely used because of its precision and efficient delivery of gene and cell therapies; however, choosing an injection point and defining delivery parameters to target a specified retinal location and area is an inexact science. We provide an overview of the key factors that play important roles during subretinal injections to refine the technique, enhance patient outcomes, and minimise risks. We describe the role of anatomical and physical variables that affect subretinal bleb propagation and shape and their impact on retinal integrity. We highlight the risks associated with subretinal injections and consider strategies to mitigate reflux and retinal trauma. Finally, we explore the emerging field of robotic assistance in improving intraocular manouvrability and precision to facilitate the injection procedure.
期刊介绍:
Survey of Ophthalmology is a clinically oriented review journal designed to keep ophthalmologists up to date. Comprehensive major review articles, written by experts and stringently refereed, integrate the literature on subjects selected for their clinical importance. Survey also includes feature articles, section reviews, book reviews, and abstracts.