对人工智能召回和未召回的筛查出的癌症进行前瞻性分析。

IF 2 Q3 ONCOLOGY Journal of Breast Imaging Pub Date : 2024-07-30 DOI:10.1093/jbi/wbae027
Samantha J Smith, Sally Anne Bradley, Katie Walker-Stabeler, Michael Siafakas
{"title":"对人工智能召回和未召回的筛查出的癌症进行前瞻性分析。","authors":"Samantha J Smith, Sally Anne Bradley, Katie Walker-Stabeler, Michael Siafakas","doi":"10.1093/jbi/wbae027","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The use of artificial intelligence has potential in assisting many aspects of imaging interpretation. We undertook a prospective service evaluation from March to October 2022 of Mammography Intelligent Assessment (MIA) operating \"silently\" within our Breast Screening Service, with a view to establishing its performance in the local population and setting. This evaluation addressed the performance of standalone MIA vs conventional double human reading of mammograms.</p><p><strong>Methods: </strong>MIA analyzed 8779 screening events over an 8-month period. The MIA outcome did not influence the decisions made on the clinical pathway. Cases were reviewed approximately 6 weeks after the screen reading decision when human reading and/or MIA indicated a recall.</p><p><strong>Results: </strong>There were 146 women with positive concordance between human reading and MIA (human reader and MIA recalled) in whom 58 breast cancers were detected. There were 270 women with negative discordance (MIA no recall, human reader recall) for whom 19 breast cancers and 1 breast lymphoma were detected, with 1 cancer being an incidental finding at assessment. Six hundred and four women had positive discordance (MIA recall, human reader no recall) in whom 2 breast cancers were detected at review. The breast cancers demonstrated a wide spectrum of mammographic features, sites, sizes, and pathologies, with no statistically significant difference in features between the negative discordant and positive concordant cases.</p><p><strong>Conclusion: </strong>Of 79 breast cancers identified by human readers, 18 were not identified by MIA, and these had no specific features or site to suggest a systematic error for MIA analysis of 2D screening mammograms.</p>","PeriodicalId":43134,"journal":{"name":"Journal of Breast Imaging","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Prospective Analysis of Screen-Detected Cancers Recalled and Not Recalled by Artificial Intelligence.\",\"authors\":\"Samantha J Smith, Sally Anne Bradley, Katie Walker-Stabeler, Michael Siafakas\",\"doi\":\"10.1093/jbi/wbae027\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The use of artificial intelligence has potential in assisting many aspects of imaging interpretation. We undertook a prospective service evaluation from March to October 2022 of Mammography Intelligent Assessment (MIA) operating \\\"silently\\\" within our Breast Screening Service, with a view to establishing its performance in the local population and setting. This evaluation addressed the performance of standalone MIA vs conventional double human reading of mammograms.</p><p><strong>Methods: </strong>MIA analyzed 8779 screening events over an 8-month period. The MIA outcome did not influence the decisions made on the clinical pathway. Cases were reviewed approximately 6 weeks after the screen reading decision when human reading and/or MIA indicated a recall.</p><p><strong>Results: </strong>There were 146 women with positive concordance between human reading and MIA (human reader and MIA recalled) in whom 58 breast cancers were detected. There were 270 women with negative discordance (MIA no recall, human reader recall) for whom 19 breast cancers and 1 breast lymphoma were detected, with 1 cancer being an incidental finding at assessment. Six hundred and four women had positive discordance (MIA recall, human reader no recall) in whom 2 breast cancers were detected at review. The breast cancers demonstrated a wide spectrum of mammographic features, sites, sizes, and pathologies, with no statistically significant difference in features between the negative discordant and positive concordant cases.</p><p><strong>Conclusion: </strong>Of 79 breast cancers identified by human readers, 18 were not identified by MIA, and these had no specific features or site to suggest a systematic error for MIA analysis of 2D screening mammograms.</p>\",\"PeriodicalId\":43134,\"journal\":{\"name\":\"Journal of Breast Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-07-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Breast Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1093/jbi/wbae027\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ONCOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Breast Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jbi/wbae027","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:人工智能的使用在协助影像解读的许多方面都具有潜力。从 2022 年 3 月到 10 月,我们对乳腺筛查服务中 "静默 "运行的乳腺智能评估(MIA)进行了前瞻性服务评估,以确定其在当地人群和环境中的表现。这项评估针对独立的 MIA 与传统的双人乳房 X 光检查读片的性能进行了比较:方法:MIA 对 8 个月内的 8779 例筛查事件进行了分析。MIA 的结果不会影响临床路径的决策。当人工读片和/或 MIA 显示需要召回时,在做出筛查决定约 6 周后对病例进行复查:结果:146 名妇女的人工读片与 MIA 呈阳性一致(人工读片和 MIA 均显示召回),其中有 58 例检测出乳腺癌。有 270 名妇女的不一致性为阴性(MIA 不显示召回,人类阅读器显示召回),其中检测出 19 例乳腺癌和 1 例乳腺淋巴瘤,1 例癌症是评估时偶然发现的。有 64 名妇女的不一致性为阳性(MIA 可回忆,人类读者不可回忆),在复查时发现了 2 例乳腺癌。这些乳腺癌在乳腺 X 线摄影特征、部位、大小和病理方面表现出广泛的多样性,阴性不一致和阳性一致病例在特征方面没有显著的统计学差异:结论:在人类阅读器识别出的 79 例乳腺癌中,有 18 例未被 MIA 识别,这些乳腺癌没有特定的特征或部位,表明对二维筛查乳房 X 光片进行 MIA 分析存在系统误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Prospective Analysis of Screen-Detected Cancers Recalled and Not Recalled by Artificial Intelligence.

Objective: The use of artificial intelligence has potential in assisting many aspects of imaging interpretation. We undertook a prospective service evaluation from March to October 2022 of Mammography Intelligent Assessment (MIA) operating "silently" within our Breast Screening Service, with a view to establishing its performance in the local population and setting. This evaluation addressed the performance of standalone MIA vs conventional double human reading of mammograms.

Methods: MIA analyzed 8779 screening events over an 8-month period. The MIA outcome did not influence the decisions made on the clinical pathway. Cases were reviewed approximately 6 weeks after the screen reading decision when human reading and/or MIA indicated a recall.

Results: There were 146 women with positive concordance between human reading and MIA (human reader and MIA recalled) in whom 58 breast cancers were detected. There were 270 women with negative discordance (MIA no recall, human reader recall) for whom 19 breast cancers and 1 breast lymphoma were detected, with 1 cancer being an incidental finding at assessment. Six hundred and four women had positive discordance (MIA recall, human reader no recall) in whom 2 breast cancers were detected at review. The breast cancers demonstrated a wide spectrum of mammographic features, sites, sizes, and pathologies, with no statistically significant difference in features between the negative discordant and positive concordant cases.

Conclusion: Of 79 breast cancers identified by human readers, 18 were not identified by MIA, and these had no specific features or site to suggest a systematic error for MIA analysis of 2D screening mammograms.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.40
自引率
20.00%
发文量
81
期刊最新文献
Performance of Abbreviated Breast MRI in High-Risk Patients in a Tertiary Care Academic Medical Center. Developing a Career as a Clinician-Educator in Breast Imaging. Unknown Case: Non-mass Enhancement on Baseline MRI. Developing Financial Acumen as a Breast Imaging Radiologist. Methodological Considerations in Evaluating Breast Cancer Screening Studies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1