C X Jin, M W Lou, X J Cai, M X Li, Q C Huang, L N Niu, C Huang
{"title":"[上颌前牙二维照片与三维数字牙科模型对比分析]。","authors":"C X Jin, M W Lou, X J Cai, M X Li, Q C Huang, L N Niu, C Huang","doi":"10.3760/cma.j.cn112144-20240205-00065","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To assess the accuracy of two-dimensional (2D) photographs in measuring esthetic parameters of the maxillary anterior teeth by comparing them with measurements obtained from three-dimensional (3D) dental models. <b>Methods:</b> A total of one hundred volunteers (49 males, 51 females, aged 18-23 years) were recruited from School and Hospital of Stomatology, Wuhan University from January to February 2024. 3D digital models of their dentitions were obtained using an intraoral scanner, and standardized frontal 2D intraoral photographs were captured with a digital camera. The lengths, widths and width/length ratio of the bilateral incisors, lateral incisors and canines were measured on both the 3D digital models and the 2D intraoral photographs. The width ratios of adjacent maxillary anterior were also calculated on the 2D intraoral photographs and the frontal view of 3D digital models. <b>Results:</b> The widths of lateral incisors [(5.85±0.60) mm] and canines [(4.73±0.71) mm] and the lengths of canines [(8.72±0.96) mm] in the 2D intraoral photographs were significantly lower than those in 3D digital models [(6.65±0.59), (7.76±0.60), (8.90±0.86) mm] (<i>t=</i>-18.24, <i>P<</i>0.001; <i>t=</i>-54.43, <i>P<</i>0.001; <i>t=</i>-4.40, <i>P<</i>0.001), while there were no significant differences in the lengths and widths of the other teeth (<i>P></i>0.05). The width/length ratios measured from the 2D intraoral photographs for the lateral incisors and canines (0.74±0.08, 0.55±0.08) were significantly lower than those measured in the 3D digital models (0.84±0.09, 0.88±0.09) (<i>t=</i>-19.68, <i>P<</i>0.001; <i>t=</i>-50.21, <i>P<</i>0.001), and the width/length ratio of the central incisors showed no significant difference between the two groups (<i>P></i>0.05). The width ratios of canines/lateral incisors and lateral incisors/central incisors measured on the 2D intraoral photographs (0.72±0.06, 0.85±0.11) were significantly smaller than those measured in the frontal view of 3D digital models (0.75±0.06, 0.89±0.11) (<i>t=</i>-9.31, <i>P<</i>0.001; <i>t=</i>-6.58, <i>P<</i>0.001). <b>Conclusions:</b> There is a difference between 2D and 3D measurement results of teeth in the esthetic area and the magnitude of the difference varies with their position in the dental arch. When analyzing the measurement of the anterior teeth, it is necessary to choose the appropriate method according to the target tooth position.</p>","PeriodicalId":23965,"journal":{"name":"中华口腔医学杂志","volume":"59 6","pages":"565-570"},"PeriodicalIF":0.0000,"publicationDate":"2024-06-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[A two-dimensional photographic and three-dimensional digital dental model comparative analysis in maxillary anterior teeth].\",\"authors\":\"C X Jin, M W Lou, X J Cai, M X Li, Q C Huang, L N Niu, C Huang\",\"doi\":\"10.3760/cma.j.cn112144-20240205-00065\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objective:</b> To assess the accuracy of two-dimensional (2D) photographs in measuring esthetic parameters of the maxillary anterior teeth by comparing them with measurements obtained from three-dimensional (3D) dental models. <b>Methods:</b> A total of one hundred volunteers (49 males, 51 females, aged 18-23 years) were recruited from School and Hospital of Stomatology, Wuhan University from January to February 2024. 3D digital models of their dentitions were obtained using an intraoral scanner, and standardized frontal 2D intraoral photographs were captured with a digital camera. The lengths, widths and width/length ratio of the bilateral incisors, lateral incisors and canines were measured on both the 3D digital models and the 2D intraoral photographs. The width ratios of adjacent maxillary anterior were also calculated on the 2D intraoral photographs and the frontal view of 3D digital models. <b>Results:</b> The widths of lateral incisors [(5.85±0.60) mm] and canines [(4.73±0.71) mm] and the lengths of canines [(8.72±0.96) mm] in the 2D intraoral photographs were significantly lower than those in 3D digital models [(6.65±0.59), (7.76±0.60), (8.90±0.86) mm] (<i>t=</i>-18.24, <i>P<</i>0.001; <i>t=</i>-54.43, <i>P<</i>0.001; <i>t=</i>-4.40, <i>P<</i>0.001), while there were no significant differences in the lengths and widths of the other teeth (<i>P></i>0.05). The width/length ratios measured from the 2D intraoral photographs for the lateral incisors and canines (0.74±0.08, 0.55±0.08) were significantly lower than those measured in the 3D digital models (0.84±0.09, 0.88±0.09) (<i>t=</i>-19.68, <i>P<</i>0.001; <i>t=</i>-50.21, <i>P<</i>0.001), and the width/length ratio of the central incisors showed no significant difference between the two groups (<i>P></i>0.05). The width ratios of canines/lateral incisors and lateral incisors/central incisors measured on the 2D intraoral photographs (0.72±0.06, 0.85±0.11) were significantly smaller than those measured in the frontal view of 3D digital models (0.75±0.06, 0.89±0.11) (<i>t=</i>-9.31, <i>P<</i>0.001; <i>t=</i>-6.58, <i>P<</i>0.001). <b>Conclusions:</b> There is a difference between 2D and 3D measurement results of teeth in the esthetic area and the magnitude of the difference varies with their position in the dental arch. When analyzing the measurement of the anterior teeth, it is necessary to choose the appropriate method according to the target tooth position.</p>\",\"PeriodicalId\":23965,\"journal\":{\"name\":\"中华口腔医学杂志\",\"volume\":\"59 6\",\"pages\":\"565-570\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华口腔医学杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/cma.j.cn112144-20240205-00065\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华口腔医学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn112144-20240205-00065","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
[A two-dimensional photographic and three-dimensional digital dental model comparative analysis in maxillary anterior teeth].
Objective: To assess the accuracy of two-dimensional (2D) photographs in measuring esthetic parameters of the maxillary anterior teeth by comparing them with measurements obtained from three-dimensional (3D) dental models. Methods: A total of one hundred volunteers (49 males, 51 females, aged 18-23 years) were recruited from School and Hospital of Stomatology, Wuhan University from January to February 2024. 3D digital models of their dentitions were obtained using an intraoral scanner, and standardized frontal 2D intraoral photographs were captured with a digital camera. The lengths, widths and width/length ratio of the bilateral incisors, lateral incisors and canines were measured on both the 3D digital models and the 2D intraoral photographs. The width ratios of adjacent maxillary anterior were also calculated on the 2D intraoral photographs and the frontal view of 3D digital models. Results: The widths of lateral incisors [(5.85±0.60) mm] and canines [(4.73±0.71) mm] and the lengths of canines [(8.72±0.96) mm] in the 2D intraoral photographs were significantly lower than those in 3D digital models [(6.65±0.59), (7.76±0.60), (8.90±0.86) mm] (t=-18.24, P<0.001; t=-54.43, P<0.001; t=-4.40, P<0.001), while there were no significant differences in the lengths and widths of the other teeth (P>0.05). The width/length ratios measured from the 2D intraoral photographs for the lateral incisors and canines (0.74±0.08, 0.55±0.08) were significantly lower than those measured in the 3D digital models (0.84±0.09, 0.88±0.09) (t=-19.68, P<0.001; t=-50.21, P<0.001), and the width/length ratio of the central incisors showed no significant difference between the two groups (P>0.05). The width ratios of canines/lateral incisors and lateral incisors/central incisors measured on the 2D intraoral photographs (0.72±0.06, 0.85±0.11) were significantly smaller than those measured in the frontal view of 3D digital models (0.75±0.06, 0.89±0.11) (t=-9.31, P<0.001; t=-6.58, P<0.001). Conclusions: There is a difference between 2D and 3D measurement results of teeth in the esthetic area and the magnitude of the difference varies with their position in the dental arch. When analyzing the measurement of the anterior teeth, it is necessary to choose the appropriate method according to the target tooth position.
期刊介绍:
Founded in August 1953, Chinese Journal of Stomatology is a monthly academic journal of stomatology published publicly at home and abroad, sponsored by the Chinese Medical Association and co-sponsored by the Chinese Stomatology Association. It mainly reports the leading scientific research results and clinical diagnosis and treatment experience in the field of oral medicine, as well as the basic theoretical research that has a guiding role in oral clinical practice and is closely combined with oral clinical practice.
Chinese Journal of Over the years, Stomatology has been published in Medline, Scopus database, Toxicology Abstracts Database, Chemical Abstracts Database, American Cancer database, Russian Abstracts database, China Core Journal of Science and Technology, Peking University Core Journal, CSCD and other more than 20 important journals at home and abroad Physical medicine database and retrieval system included.