{"title":"非牛顿四元混合纳米流体模型通过有界动脉在血液中实现立方自催化作用","authors":"Wael Al-Kouz, Wahib Owhaib, Basma Souayeh, Montasir Hader, Raad Z. Homod","doi":"10.1515/arh-2024-0007","DOIUrl":null,"url":null,"abstract":"Tetra hybrid nanofluids are significant due to their unique properties like thermal and electrical conductivity enhancement, increased heat transfer, and improved fluid flow characteristics. This attempt proposes a tetra hybrid cross nanofluid model with the implementation of cubic autocatalysis in the context of blood flow passing through a stenosis artery. The model includes the effects of nanofluid, magnetic field, thermal radiation, and the cubic autocatalysis mechanism. This research investigates the innovative application of cubic autocatalysis within the context of blood flow through a tetra hybrid cross nanofluid model, specifically designed to simulate conditions within a stenosis horizontal artery. The equations governing the fluid flow are solved using the bvp5c method, and the numerical solutions are obtained for various parameter values. Specifically, the cubic autocatalysis mechanism profoundly impacts the velocity and concentration profiles of the blood flow. The proposed model and the obtained results provide new insights into the physics of blood flow passing through stenosis arteries. They may have important implications for the diagnosis and treatment of cardiovascular diseases. This article has a unique combination of tetra hybrid cross nanofluid model, cubic autocatalysis, and blood flow passing through the stenosis artery. These facts are not typically studied together in the context of blood flow.","PeriodicalId":50738,"journal":{"name":"Applied Rheology","volume":"57 1","pages":""},"PeriodicalIF":5.8000,"publicationDate":"2024-05-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cubic autocatalysis implementation in blood for non-Newtonian tetra hybrid nanofluid model through bounded artery\",\"authors\":\"Wael Al-Kouz, Wahib Owhaib, Basma Souayeh, Montasir Hader, Raad Z. Homod\",\"doi\":\"10.1515/arh-2024-0007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Tetra hybrid nanofluids are significant due to their unique properties like thermal and electrical conductivity enhancement, increased heat transfer, and improved fluid flow characteristics. This attempt proposes a tetra hybrid cross nanofluid model with the implementation of cubic autocatalysis in the context of blood flow passing through a stenosis artery. The model includes the effects of nanofluid, magnetic field, thermal radiation, and the cubic autocatalysis mechanism. This research investigates the innovative application of cubic autocatalysis within the context of blood flow through a tetra hybrid cross nanofluid model, specifically designed to simulate conditions within a stenosis horizontal artery. The equations governing the fluid flow are solved using the bvp5c method, and the numerical solutions are obtained for various parameter values. Specifically, the cubic autocatalysis mechanism profoundly impacts the velocity and concentration profiles of the blood flow. The proposed model and the obtained results provide new insights into the physics of blood flow passing through stenosis arteries. They may have important implications for the diagnosis and treatment of cardiovascular diseases. This article has a unique combination of tetra hybrid cross nanofluid model, cubic autocatalysis, and blood flow passing through the stenosis artery. These facts are not typically studied together in the context of blood flow.\",\"PeriodicalId\":50738,\"journal\":{\"name\":\"Applied Rheology\",\"volume\":\"57 1\",\"pages\":\"\"},\"PeriodicalIF\":5.8000,\"publicationDate\":\"2024-05-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Rheology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1515/arh-2024-0007\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MECHANICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Rheology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1515/arh-2024-0007","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MECHANICS","Score":null,"Total":0}
Cubic autocatalysis implementation in blood for non-Newtonian tetra hybrid nanofluid model through bounded artery
Tetra hybrid nanofluids are significant due to their unique properties like thermal and electrical conductivity enhancement, increased heat transfer, and improved fluid flow characteristics. This attempt proposes a tetra hybrid cross nanofluid model with the implementation of cubic autocatalysis in the context of blood flow passing through a stenosis artery. The model includes the effects of nanofluid, magnetic field, thermal radiation, and the cubic autocatalysis mechanism. This research investigates the innovative application of cubic autocatalysis within the context of blood flow through a tetra hybrid cross nanofluid model, specifically designed to simulate conditions within a stenosis horizontal artery. The equations governing the fluid flow are solved using the bvp5c method, and the numerical solutions are obtained for various parameter values. Specifically, the cubic autocatalysis mechanism profoundly impacts the velocity and concentration profiles of the blood flow. The proposed model and the obtained results provide new insights into the physics of blood flow passing through stenosis arteries. They may have important implications for the diagnosis and treatment of cardiovascular diseases. This article has a unique combination of tetra hybrid cross nanofluid model, cubic autocatalysis, and blood flow passing through the stenosis artery. These facts are not typically studied together in the context of blood flow.
期刊介绍:
Applied Rheology is a peer-reviewed, open access, electronic journal devoted to the publication in the field of applied rheology. The journal provides the readers with free, instant, and permanent access to all content worldwide; and the authors with extensive promotion of published articles, long-time preservation, language-correction services, no space constraints and immediate publication.