{"title":"INRIM (意大利)和 BIPM 之间 1.018 V 和 10 V 标准的双边比较,2023 年 11 月至 12 月(BIPM.EM-K11.a 和 b 正在进行的关键比较的一部分)。","authors":"S Solve, R Chayramy, M Stock, P Durandetto and E Enrico","doi":"10.1088/0026-1394/61/1a/01004","DOIUrl":null,"url":null,"abstract":"As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the INRIM (Italy), from November to December 2023. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_7 (Z7) and BIPM_9 (Z9), were transported by freight to the INRIM and back to the BIPM. In order to keep the Zeners powered during their transportation phase, two additional external batteries were connected in parallel to the internal battery. At the INRIM and the BIPM, the reference standard for DC voltage is a Programmable Josephson Voltage Standard (PJVS). The output electromotive force (EMF) of each travelling standard was measured by direct comparison with the primary standard. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by the INRIM, at the level of 1.018 V and 10 V, at the INRIM, UINRIM, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 1st of December 2023. UINRIM - UBIPM = 0.06 V; uc = 0.05 V, at 1.018 V UINRIM - UBIPM = 0.22 V; uc = 0.12 V, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the realisation of the volt at the BIPM and at the INRIM, and the uncertainty related to the comparison. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).","PeriodicalId":18444,"journal":{"name":"Metrologia","volume":"24 1","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2024-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Bilateral comparison of 1.018 V and 10 V standards between INRIM (Italy) and the BIPM, November to December 2023 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)\",\"authors\":\"S Solve, R Chayramy, M Stock, P Durandetto and E Enrico\",\"doi\":\"10.1088/0026-1394/61/1a/01004\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the INRIM (Italy), from November to December 2023. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_7 (Z7) and BIPM_9 (Z9), were transported by freight to the INRIM and back to the BIPM. In order to keep the Zeners powered during their transportation phase, two additional external batteries were connected in parallel to the internal battery. At the INRIM and the BIPM, the reference standard for DC voltage is a Programmable Josephson Voltage Standard (PJVS). The output electromotive force (EMF) of each travelling standard was measured by direct comparison with the primary standard. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by the INRIM, at the level of 1.018 V and 10 V, at the INRIM, UINRIM, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 1st of December 2023. UINRIM - UBIPM = 0.06 V; uc = 0.05 V, at 1.018 V UINRIM - UBIPM = 0.22 V; uc = 0.12 V, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the realisation of the volt at the BIPM and at the INRIM, and the uncertainty related to the comparison. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).\",\"PeriodicalId\":18444,\"journal\":{\"name\":\"Metrologia\",\"volume\":\"24 1\",\"pages\":\"\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metrologia\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1088/0026-1394/61/1a/01004\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metrologia","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/0026-1394/61/1a/01004","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0
摘要
作为正在进行的 BIPM 关键比较 BIPM.EM-K11.a 和 b 的一部分,从 2023 年 11 月至 12 月,对 BIPM 和 INRIM(意大利)的 1.018 V 和 10 V 电压基准标准进行了比较。BIPM 的两个基于齐纳二极管的巡回标准(Fluke 732B),BIPM_7 (Z7) 和 BIPM_9 (Z9),通过货运运往 INRIM,再运回 BIPM。为了在运输过程中保持禅思机的电力供应,另外两个外部电池与内部电池并联。在 INRIM 和 BIPM,直流电压的参考标准是可编程约瑟夫森电压标准 (PJVS)。每个巡回标准的输出电动势(EMF)都是通过与主标准直接比较来测量的。比较的最终结果是,在 2023 年 12 月 1 日的基准日期,国际海事研究所(INRIM,UINRIM)为 1.018 V 和 10 V 等级的直流电压标准分配的数值与国际计量局(BIPM,UBIPM)为 1.018 V 和 10 V 等级的直流电压标准分配的数值之间的差值。UINRIM - UBIPM = 0.06 V; uc = 0.05 V, at 1.018 V UINRIM - UBIPM = 0.22 V; uc = 0.12 V, at 10 V 其中,uc 是与测量差值相关的综合标准不确定度,包括在 BIPM 和 INRIM 实现电压的不确定度,以及与比较相关的不确定度。要阅读本文正文,请点击最终报告。请注意,该文本是出现在国际计量局关键比较数据库 https://www.bipm.org/kcdb/ 附录 B 中的文本。根据 CIPM 互认安排 (CIPM MRA) 的规定,最终报告已经过同行评审,并获准由 CCEM 出版。
Bilateral comparison of 1.018 V and 10 V standards between INRIM (Italy) and the BIPM, November to December 2023 (part of the ongoing BIPM key comparison BIPM.EM-K11.a and b)
As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the INRIM (Italy), from November to December 2023. Two BIPM Zener diode-based travelling standards (Fluke 732B), BIPM_7 (Z7) and BIPM_9 (Z9), were transported by freight to the INRIM and back to the BIPM. In order to keep the Zeners powered during their transportation phase, two additional external batteries were connected in parallel to the internal battery. At the INRIM and the BIPM, the reference standard for DC voltage is a Programmable Josephson Voltage Standard (PJVS). The output electromotive force (EMF) of each travelling standard was measured by direct comparison with the primary standard. The final result of the comparison is presented as the difference between the values assigned to DC voltage standards by the INRIM, at the level of 1.018 V and 10 V, at the INRIM, UINRIM, and those assigned by the BIPM, at the BIPM, UBIPM, at the reference date of the 1st of December 2023. UINRIM - UBIPM = 0.06 V; uc = 0.05 V, at 1.018 V UINRIM - UBIPM = 0.22 V; uc = 0.12 V, at 10 V where uc is the combined standard uncertainty associated with the measured difference, including the uncertainty of the realisation of the volt at the BIPM and at the INRIM, and the uncertainty related to the comparison. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
期刊介绍:
Published 6 times per year, Metrologia covers the fundamentals of measurements, particularly those dealing with the seven base units of the International System of Units (metre, kilogram, second, ampere, kelvin, candela, mole) or proposals to replace them.
The journal also publishes papers that contribute to the solution of difficult measurement problems and improve the accuracy of derived units and constants that are of fundamental importance to physics.
In addition to regular papers, the journal publishes review articles, issues devoted to single topics of timely interest and occasional conference proceedings. Letters to the Editor and Short Communications (generally three pages or less) are also considered.