使用黄金标准听力测定法和 TympaHealth 听力评估工具比较听力阈值以及由此产生的规定增益和助听器输出。

IF 1.4 4区 医学 Q3 AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY American Journal of Audiology Pub Date : 2024-09-03 Epub Date: 2024-06-07 DOI:10.1044/2024_AJA-24-00002
Gabrielle H Saunders, Adam Walker, Calvin Heal, Krishan Ramdoo
{"title":"使用黄金标准听力测定法和 TympaHealth 听力评估工具比较听力阈值以及由此产生的规定增益和助听器输出。","authors":"Gabrielle H Saunders, Adam Walker, Calvin Heal, Krishan Ramdoo","doi":"10.1044/2024_AJA-24-00002","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Phone- and tablet-based hearing testing systems are now widely available. Here, we evaluated one such system from TympaHealth by comparing air conduction thresholds and resultant hearing aid targets and output, measured with the TympaHealth system with those measured using standard audiometry.</p><p><strong>Design: </strong>The hearing thresholds of 35 adults were measured using standard audiometry and the TympaHealth system. Each set of thresholds was used to generate NAL-NL2 targets and program a hearing aid. The data from each system were compared.</p><p><strong>Results: </strong>Bland-Altman analyses showed overall mean differences between thresholds measured with each system to be small, with 85% of TympaHealth thresholds being within ±5 dB of the standard audiometric thresholds, although TympaHealth thresholds were higher (poorer) than the standard audiometric thresholds. The hearing aid targets and gains generated from the standard audiometric thresholds were lower (less amplification) than those generated from the TympaHealth thresholds but again, mean differences at each frequency were small and likely imperceptible.</p><p><strong>Conclusion: </strong>These findings support the possibility that valid hearing testing can take place outside of a clinical booth using portable systems like that from TympaHealth, opening up the possibility of testing hearing and fitting hearing aids through pharmacies, opticians, and in care homes.</p>","PeriodicalId":49241,"journal":{"name":"American Journal of Audiology","volume":" ","pages":"740-755"},"PeriodicalIF":1.4000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Comparison of Hearing Thresholds, and the Resulting Prescribed Gain and Hearing Aid Outputs, Using Gold Standard Audiometry and the TympaHealth Hearing Assessment Tool.\",\"authors\":\"Gabrielle H Saunders, Adam Walker, Calvin Heal, Krishan Ramdoo\",\"doi\":\"10.1044/2024_AJA-24-00002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>Phone- and tablet-based hearing testing systems are now widely available. Here, we evaluated one such system from TympaHealth by comparing air conduction thresholds and resultant hearing aid targets and output, measured with the TympaHealth system with those measured using standard audiometry.</p><p><strong>Design: </strong>The hearing thresholds of 35 adults were measured using standard audiometry and the TympaHealth system. Each set of thresholds was used to generate NAL-NL2 targets and program a hearing aid. The data from each system were compared.</p><p><strong>Results: </strong>Bland-Altman analyses showed overall mean differences between thresholds measured with each system to be small, with 85% of TympaHealth thresholds being within ±5 dB of the standard audiometric thresholds, although TympaHealth thresholds were higher (poorer) than the standard audiometric thresholds. The hearing aid targets and gains generated from the standard audiometric thresholds were lower (less amplification) than those generated from the TympaHealth thresholds but again, mean differences at each frequency were small and likely imperceptible.</p><p><strong>Conclusion: </strong>These findings support the possibility that valid hearing testing can take place outside of a clinical booth using portable systems like that from TympaHealth, opening up the possibility of testing hearing and fitting hearing aids through pharmacies, opticians, and in care homes.</p>\",\"PeriodicalId\":49241,\"journal\":{\"name\":\"American Journal of Audiology\",\"volume\":\" \",\"pages\":\"740-755\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-09-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of Audiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1044/2024_AJA-24-00002\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Audiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1044/2024_AJA-24-00002","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/7 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:基于手机和平板电脑的听力测试系统现已广泛使用。在此,我们对 TympaHealth 的此类系统进行了评估,比较了 TympaHealth 系统与标准测听法测量的气导阈值、助听器目标和输出结果:设计:使用标准测听法和 TympaHealth 系统测量 35 名成人的听阈。每组阈值用于生成 NAL-NL2 目标值和助听器编程。对每个系统的数据进行比较:结果:Bland-Altman分析表明,每套系统测得的阈值之间的总体平均差异很小,85%的TympaHealth阈值与标准测听阈值在±5 dB以内,尽管TympaHealth阈值比标准测听阈值更高(更差)。根据标准测听阈值生成的助听器目标值和增益低于根据 TympaHealth 测听阈值生成的助听器目标值和增益(放大率较低),但每个频率的平均差异较小,可能不易察觉:这些研究结果证明,使用 TympaHealth 的便携式系统可以在临床室外进行有效的听力测试,从而为通过药店、眼镜店和护理院进行听力测试和助听器验配提供了可能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Comparison of Hearing Thresholds, and the Resulting Prescribed Gain and Hearing Aid Outputs, Using Gold Standard Audiometry and the TympaHealth Hearing Assessment Tool.

Objective: Phone- and tablet-based hearing testing systems are now widely available. Here, we evaluated one such system from TympaHealth by comparing air conduction thresholds and resultant hearing aid targets and output, measured with the TympaHealth system with those measured using standard audiometry.

Design: The hearing thresholds of 35 adults were measured using standard audiometry and the TympaHealth system. Each set of thresholds was used to generate NAL-NL2 targets and program a hearing aid. The data from each system were compared.

Results: Bland-Altman analyses showed overall mean differences between thresholds measured with each system to be small, with 85% of TympaHealth thresholds being within ±5 dB of the standard audiometric thresholds, although TympaHealth thresholds were higher (poorer) than the standard audiometric thresholds. The hearing aid targets and gains generated from the standard audiometric thresholds were lower (less amplification) than those generated from the TympaHealth thresholds but again, mean differences at each frequency were small and likely imperceptible.

Conclusion: These findings support the possibility that valid hearing testing can take place outside of a clinical booth using portable systems like that from TympaHealth, opening up the possibility of testing hearing and fitting hearing aids through pharmacies, opticians, and in care homes.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
American Journal of Audiology
American Journal of Audiology AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY-OTORHINOLARYNGOLOGY
CiteScore
3.00
自引率
16.70%
发文量
163
审稿时长
>12 weeks
期刊介绍: Mission: AJA publishes peer-reviewed research and other scholarly articles pertaining to clinical audiology methods and issues, and serves as an outlet for discussion of related professional and educational issues and ideas. The journal is an international outlet for research on clinical research pertaining to screening, diagnosis, management and outcomes of hearing and balance disorders as well as the etiologies and characteristics of these disorders. The clinical orientation of the journal allows for the publication of reports on audiology as implemented nationally and internationally, including novel clinical procedures, approaches, and cases. AJA seeks to advance evidence-based practice by disseminating the results of new studies as well as providing a forum for critical reviews and meta-analyses of previously published work. Scope: The broad field of clinical audiology, including audiologic/aural rehabilitation; balance and balance disorders; cultural and linguistic diversity; detection, diagnosis, prevention, habilitation, rehabilitation, and monitoring of hearing loss; hearing aids, cochlear implants, and hearing-assistive technology; hearing disorders; lifespan perspectives on auditory function; speech perception; and tinnitus.
期刊最新文献
Effects of Noise Exposure on Video Ocular Counter Roll Measurements. Influence of Matching the Processing Delays of Cochlear Implant and Hearing Aid Devices for Bimodal Listeners on Speech Recognition in Noise. Unlocking the Potential of Pediatric Virtual Care: An e-Delphi Study on a Virtual Caregiver Participation Framework in Audiology. Alignment of Audiologists' Values With Best-Practice Standards: Insights From a National Survey. Assessment of a Hearing Aid Training Program for Health Care Workers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1