Corey Keenan, Hillary Danis, Jim Fraley, Jack Roets, Holly Spitzer, Samuel Grasso
{"title":"可怕的 3 分钟等待:它真的能预防手术室火灾吗?IGNITE 试验。","authors":"Corey Keenan, Hillary Danis, Jim Fraley, Jack Roets, Holly Spitzer, Samuel Grasso","doi":"10.1093/milmed/usae300","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Operating room fires can have devastating consequences and as such must be prevented. There exists a paucity of literature requiring further elucidation regarding manufacturer recommendations of a predefined waiting period prior to patient draping after using alcohol-based surgical antiseptics, in order to reduce the risk of operating room fires.</p><p><strong>Methods: </strong>This was further investigated by exposing two common alcohol-based surgical antiseptics to electrosurgery and open flames at various power settings and time intervals in an ex vivo porcine model. The simulated surgical site was prepped following manufacturer recommendations and exposed to monopolar electrosurgery at low and high power, using both PURE CUT and COAGULATION modes, and open flame, at 15-s increments after application.</p><p><strong>Results: </strong>While using PURE CUT mode at both low and high power, no ignition was observed on hairless surgical sites prepped with ChloraPrep® at any time point. However, use of COAGULATION mode at both low and high powers resulted in ignition consistently out to 1-min post-application. Additionally, if the prepped area subjectively appeared wet, especially with pooling of the antiseptic, both COAGULATION mode and open flame caused ignition. Dry time was found to be about 59 s for both prep solutions. It was also observed that the amount of pressure directly correlated with the amount of prep dispersed and increased dry times.</p><p><strong>Conclusion: </strong>In conclusion, our data suggest an average dry time of less than 1-min, with ignition only observed when the antiseptic was visibly wet. Ignition did not occur on hairless skin with electrocautery on CUT mode using ChloraPrep at any time point. Additionally, ignition on hair-bearing skin was not observed past 3 min, with current manufacturer recommendations stating 1 h wait time for hair-bearing skin. Arbitrarily waiting a specific predetermined dry time until patient draping, as recommended by the manufacturers, may be unnecessary and lead to hours' worth of time wasted each year. Ongoing research will further investigate the utility of drying the antiseptic after application and its affect on not only preventing ignition but also antimicrobial efficacy.</p>","PeriodicalId":18638,"journal":{"name":"Military Medicine","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Dreaded 3-Minute Wait: Does It Really Prevent Operating Room Fires? The IGNITE Trial.\",\"authors\":\"Corey Keenan, Hillary Danis, Jim Fraley, Jack Roets, Holly Spitzer, Samuel Grasso\",\"doi\":\"10.1093/milmed/usae300\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Operating room fires can have devastating consequences and as such must be prevented. There exists a paucity of literature requiring further elucidation regarding manufacturer recommendations of a predefined waiting period prior to patient draping after using alcohol-based surgical antiseptics, in order to reduce the risk of operating room fires.</p><p><strong>Methods: </strong>This was further investigated by exposing two common alcohol-based surgical antiseptics to electrosurgery and open flames at various power settings and time intervals in an ex vivo porcine model. The simulated surgical site was prepped following manufacturer recommendations and exposed to monopolar electrosurgery at low and high power, using both PURE CUT and COAGULATION modes, and open flame, at 15-s increments after application.</p><p><strong>Results: </strong>While using PURE CUT mode at both low and high power, no ignition was observed on hairless surgical sites prepped with ChloraPrep® at any time point. However, use of COAGULATION mode at both low and high powers resulted in ignition consistently out to 1-min post-application. Additionally, if the prepped area subjectively appeared wet, especially with pooling of the antiseptic, both COAGULATION mode and open flame caused ignition. Dry time was found to be about 59 s for both prep solutions. It was also observed that the amount of pressure directly correlated with the amount of prep dispersed and increased dry times.</p><p><strong>Conclusion: </strong>In conclusion, our data suggest an average dry time of less than 1-min, with ignition only observed when the antiseptic was visibly wet. Ignition did not occur on hairless skin with electrocautery on CUT mode using ChloraPrep at any time point. Additionally, ignition on hair-bearing skin was not observed past 3 min, with current manufacturer recommendations stating 1 h wait time for hair-bearing skin. Arbitrarily waiting a specific predetermined dry time until patient draping, as recommended by the manufacturers, may be unnecessary and lead to hours' worth of time wasted each year. Ongoing research will further investigate the utility of drying the antiseptic after application and its affect on not only preventing ignition but also antimicrobial efficacy.</p>\",\"PeriodicalId\":18638,\"journal\":{\"name\":\"Military Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-11-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Military Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/milmed/usae300\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Military Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/milmed/usae300","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
The Dreaded 3-Minute Wait: Does It Really Prevent Operating Room Fires? The IGNITE Trial.
Introduction: Operating room fires can have devastating consequences and as such must be prevented. There exists a paucity of literature requiring further elucidation regarding manufacturer recommendations of a predefined waiting period prior to patient draping after using alcohol-based surgical antiseptics, in order to reduce the risk of operating room fires.
Methods: This was further investigated by exposing two common alcohol-based surgical antiseptics to electrosurgery and open flames at various power settings and time intervals in an ex vivo porcine model. The simulated surgical site was prepped following manufacturer recommendations and exposed to monopolar electrosurgery at low and high power, using both PURE CUT and COAGULATION modes, and open flame, at 15-s increments after application.
Results: While using PURE CUT mode at both low and high power, no ignition was observed on hairless surgical sites prepped with ChloraPrep® at any time point. However, use of COAGULATION mode at both low and high powers resulted in ignition consistently out to 1-min post-application. Additionally, if the prepped area subjectively appeared wet, especially with pooling of the antiseptic, both COAGULATION mode and open flame caused ignition. Dry time was found to be about 59 s for both prep solutions. It was also observed that the amount of pressure directly correlated with the amount of prep dispersed and increased dry times.
Conclusion: In conclusion, our data suggest an average dry time of less than 1-min, with ignition only observed when the antiseptic was visibly wet. Ignition did not occur on hairless skin with electrocautery on CUT mode using ChloraPrep at any time point. Additionally, ignition on hair-bearing skin was not observed past 3 min, with current manufacturer recommendations stating 1 h wait time for hair-bearing skin. Arbitrarily waiting a specific predetermined dry time until patient draping, as recommended by the manufacturers, may be unnecessary and lead to hours' worth of time wasted each year. Ongoing research will further investigate the utility of drying the antiseptic after application and its affect on not only preventing ignition but also antimicrobial efficacy.
期刊介绍:
Military Medicine is the official international journal of AMSUS. Articles published in the journal are peer-reviewed scientific papers, case reports, and editorials. The journal also publishes letters to the editor.
The objective of the journal is to promote awareness of federal medicine by providing a forum for responsible discussion of common ideas and problems relevant to federal healthcare. Its mission is: To increase healthcare education by providing scientific and other information to its readers; to facilitate communication; and to offer a prestige publication for members’ writings.