利用田口方法、响应面方法和多元自适应回归样条分析真空操作对通过钯膜从 H2/H2O 混合物中分离氢气的影响

IF 7.1 Q1 ENERGY & FUELS Energy Conversion and Management-X Pub Date : 2024-06-08 DOI:10.1016/j.ecmx.2024.100645
Min-Hsing Chang , Wei-Hsin Chen , Dong-Ruei Wu , Mohammad Ghorbani , Saravanan Rajendran , Wan Mohd Ashri Wan Daud
{"title":"利用田口方法、响应面方法和多元自适应回归样条分析真空操作对通过钯膜从 H2/H2O 混合物中分离氢气的影响","authors":"Min-Hsing Chang ,&nbsp;Wei-Hsin Chen ,&nbsp;Dong-Ruei Wu ,&nbsp;Mohammad Ghorbani ,&nbsp;Saravanan Rajendran ,&nbsp;Wan Mohd Ashri Wan Daud","doi":"10.1016/j.ecmx.2024.100645","DOIUrl":null,"url":null,"abstract":"<div><p>The influence of vacuum pressure applied on H<sub>2</sub> separation from a palladium membrane is explored in this study. Three factors with three levels are considered, including the membrane chamber temperature with levels 320 °C, 350 °C, and 380 °C; the retentate-side total pressure with levels 1, 2, and 3 atm; and the permeation-side vacuum pressure with levels 0, 25, and 50 kPa. The Taguchi, response surface methodology (RSM), and multivariate adaptive regression splines (MARS) methods are employed to analyze the effects of the three parameters on hydrogen separation and predict their optimal combination. The retentate-side total pressure exhibits the highest impact on H<sub>2</sub> permeation, following the permeation-side vacuum pressure and then the membrane chamber temperature. The maximum H<sub>2</sub> flux is 0.226 mol∙s<sup>−1</sup>∙m<sup>−2</sup>, with H<sub>2</sub> recovery of 91 % obtained at the optimal conditions with a temperature of 380 °C, a total pressure of 3 atm, and a vacuum pressure of 50 kPa. The improvement in H<sub>2</sub> flux reaches 21.6 % compared with the case without the imposed vacuum pressure at the same temperature and total pressure. This result shows the imposed vacuum pressure is an efficient way to enhance H<sub>2</sub> permeation. The maximum relative errors between the experimental data and the predictions from the Taguchi, RSM, and MARS methods are 6.74 %, 3.37 %, and 8.08 %, respectively. The RSM method presents higher accuracy than Taguchi and MARS, perhaps due to a more precise analysis of the interaction terms. The smaller amount of input data and ignoring the temperature effect in MARS could be the reason for the lower accuracy. Nevertheless, the MARS method still demonstrates acceptable results. The cost of the Taguchi method is lower than that of the RSM method since it requires fewer experimental cases. In a word, the choice of the prediction method depends on the desired accuracy and the experimental cost.</p></div>","PeriodicalId":37131,"journal":{"name":"Energy Conversion and Management-X","volume":null,"pages":null},"PeriodicalIF":7.1000,"publicationDate":"2024-06-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2590174524001235/pdfft?md5=b76ccd162204d6fec940089be7c2abd0&pid=1-s2.0-S2590174524001235-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Analysis of vacuum operation on hydrogen separation from H2/H2O mixture via Pd membrane using Taguchi method, response surface methodology, and multivariate adaptive regression splines\",\"authors\":\"Min-Hsing Chang ,&nbsp;Wei-Hsin Chen ,&nbsp;Dong-Ruei Wu ,&nbsp;Mohammad Ghorbani ,&nbsp;Saravanan Rajendran ,&nbsp;Wan Mohd Ashri Wan Daud\",\"doi\":\"10.1016/j.ecmx.2024.100645\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The influence of vacuum pressure applied on H<sub>2</sub> separation from a palladium membrane is explored in this study. Three factors with three levels are considered, including the membrane chamber temperature with levels 320 °C, 350 °C, and 380 °C; the retentate-side total pressure with levels 1, 2, and 3 atm; and the permeation-side vacuum pressure with levels 0, 25, and 50 kPa. The Taguchi, response surface methodology (RSM), and multivariate adaptive regression splines (MARS) methods are employed to analyze the effects of the three parameters on hydrogen separation and predict their optimal combination. The retentate-side total pressure exhibits the highest impact on H<sub>2</sub> permeation, following the permeation-side vacuum pressure and then the membrane chamber temperature. The maximum H<sub>2</sub> flux is 0.226 mol∙s<sup>−1</sup>∙m<sup>−2</sup>, with H<sub>2</sub> recovery of 91 % obtained at the optimal conditions with a temperature of 380 °C, a total pressure of 3 atm, and a vacuum pressure of 50 kPa. The improvement in H<sub>2</sub> flux reaches 21.6 % compared with the case without the imposed vacuum pressure at the same temperature and total pressure. This result shows the imposed vacuum pressure is an efficient way to enhance H<sub>2</sub> permeation. The maximum relative errors between the experimental data and the predictions from the Taguchi, RSM, and MARS methods are 6.74 %, 3.37 %, and 8.08 %, respectively. The RSM method presents higher accuracy than Taguchi and MARS, perhaps due to a more precise analysis of the interaction terms. The smaller amount of input data and ignoring the temperature effect in MARS could be the reason for the lower accuracy. Nevertheless, the MARS method still demonstrates acceptable results. The cost of the Taguchi method is lower than that of the RSM method since it requires fewer experimental cases. In a word, the choice of the prediction method depends on the desired accuracy and the experimental cost.</p></div>\",\"PeriodicalId\":37131,\"journal\":{\"name\":\"Energy Conversion and Management-X\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":7.1000,\"publicationDate\":\"2024-06-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2590174524001235/pdfft?md5=b76ccd162204d6fec940089be7c2abd0&pid=1-s2.0-S2590174524001235-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Energy Conversion and Management-X\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2590174524001235\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENERGY & FUELS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energy Conversion and Management-X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2590174524001235","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENERGY & FUELS","Score":null,"Total":0}
引用次数: 0

摘要

本研究探讨了真空压力对钯膜分离 H2 的影响。考虑了三个水平的因素,包括 320 ℃、350 ℃ 和 380 ℃ 的膜室温度;1、2 和 3 atm 的截留侧总压;以及 0、25 和 50 kPa 的渗透侧真空压力。采用田口方法、响应面方法(RSM)和多元自适应回归样条法(MARS)分析了三个参数对氢气分离的影响,并预测了它们的最佳组合。截留侧总压对氢气渗透的影响最大,其次是渗透侧真空压力,再次是膜室温度。在温度为 380 °C、总压为 3 atm 和真空压力为 50 kPa 的最佳条件下,最大 H2 通量为 0.226 mol∙s-1∙m-2 ,H2 回收率为 91%。与相同温度和总压下未施加真空压力的情况相比,H2 通量提高了 21.6%。这一结果表明,外加真空压力是提高 H2 渗透率的有效方法。实验数据与 Taguchi、RSM 和 MARS 方法预测值之间的最大相对误差分别为 6.74 %、3.37 % 和 8.08 %。RSM 方法的精确度高于田口方法和 MARS 方法,这可能是由于对交互项进行了更精确的分析。在 MARS 中,输入数据量较小和忽略温度效应可能是精度较低的原因。尽管如此,MARS 方法仍然得出了可接受的结果。田口方法的成本低于 RSM 方法,因为它所需的实验案例较少。总之,预测方法的选择取决于所需的精度和实验成本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of vacuum operation on hydrogen separation from H2/H2O mixture via Pd membrane using Taguchi method, response surface methodology, and multivariate adaptive regression splines

The influence of vacuum pressure applied on H2 separation from a palladium membrane is explored in this study. Three factors with three levels are considered, including the membrane chamber temperature with levels 320 °C, 350 °C, and 380 °C; the retentate-side total pressure with levels 1, 2, and 3 atm; and the permeation-side vacuum pressure with levels 0, 25, and 50 kPa. The Taguchi, response surface methodology (RSM), and multivariate adaptive regression splines (MARS) methods are employed to analyze the effects of the three parameters on hydrogen separation and predict their optimal combination. The retentate-side total pressure exhibits the highest impact on H2 permeation, following the permeation-side vacuum pressure and then the membrane chamber temperature. The maximum H2 flux is 0.226 mol∙s−1∙m−2, with H2 recovery of 91 % obtained at the optimal conditions with a temperature of 380 °C, a total pressure of 3 atm, and a vacuum pressure of 50 kPa. The improvement in H2 flux reaches 21.6 % compared with the case without the imposed vacuum pressure at the same temperature and total pressure. This result shows the imposed vacuum pressure is an efficient way to enhance H2 permeation. The maximum relative errors between the experimental data and the predictions from the Taguchi, RSM, and MARS methods are 6.74 %, 3.37 %, and 8.08 %, respectively. The RSM method presents higher accuracy than Taguchi and MARS, perhaps due to a more precise analysis of the interaction terms. The smaller amount of input data and ignoring the temperature effect in MARS could be the reason for the lower accuracy. Nevertheless, the MARS method still demonstrates acceptable results. The cost of the Taguchi method is lower than that of the RSM method since it requires fewer experimental cases. In a word, the choice of the prediction method depends on the desired accuracy and the experimental cost.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
8.80
自引率
3.20%
发文量
180
审稿时长
58 days
期刊介绍: Energy Conversion and Management: X is the open access extension of the reputable journal Energy Conversion and Management, serving as a platform for interdisciplinary research on a wide array of critical energy subjects. The journal is dedicated to publishing original contributions and in-depth technical review articles that present groundbreaking research on topics spanning energy generation, utilization, conversion, storage, transmission, conservation, management, and sustainability. The scope of Energy Conversion and Management: X encompasses various forms of energy, including mechanical, thermal, nuclear, chemical, electromagnetic, magnetic, and electric energy. It addresses all known energy resources, highlighting both conventional sources like fossil fuels and nuclear power, as well as renewable resources such as solar, biomass, hydro, wind, geothermal, and ocean energy.
期刊最新文献
Low-GWP refrigerants in heat pumps: An experimental investigation of the influence of an internal heat exchanger Steady and transient modeling of dye-sensitive solar cells: The impact of electrode thickness and dye specifications Aggregator control of battery energy storage in wind power stations to maximize availability of regulation service Methodology to assess the impact of urban vegetation on the energy consumption of residential buildings. Case study in a Mediterranean city Electromagnetic vibrational harvester based on U-shaped ferromagnetic cantilever: A novel two-magnet configuration
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1