两例无声皮下植入式心脏除颤器电极移位。

IF 1.7 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS Pace-Pacing and Clinical Electrophysiology Pub Date : 2024-11-01 Epub Date: 2024-06-14 DOI:10.1111/pace.15023
Amy Wharmby, Charles Butcher, Shohreh Honarbakhsh, Christopher Monkhouse, Ross J Hunter
{"title":"两例无声皮下植入式心脏除颤器电极移位。","authors":"Amy Wharmby, Charles Butcher, Shohreh Honarbakhsh, Christopher Monkhouse, Ross J Hunter","doi":"10.1111/pace.15023","DOIUrl":null,"url":null,"abstract":"<p><p>We describe two cases of secondary prevention subcutaneous implantable cardioverter defibrillator (S-ICD) implantation and subsequent S-ICD electrode displacement which initially went undetected. One presentation was a result of a coincidental chest x-ray for respiratory exacerbation and another with an untreated episode highlighted via remote monitoring, both patients were booked to clinic for further investigation. Our findings highlighted had there been a comparison of the existing subcutaneous electrogram (S-ECG) to captured S-ECGs at time of implant the electrode displacement would have been detected beforehand. This underpins the importance of introducing the simple management strategy into routine follow-up.</p>","PeriodicalId":54653,"journal":{"name":"Pace-Pacing and Clinical Electrophysiology","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Two cases of silent subcutaneous implantable cardioverter defibrillator electrode displacement.\",\"authors\":\"Amy Wharmby, Charles Butcher, Shohreh Honarbakhsh, Christopher Monkhouse, Ross J Hunter\",\"doi\":\"10.1111/pace.15023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We describe two cases of secondary prevention subcutaneous implantable cardioverter defibrillator (S-ICD) implantation and subsequent S-ICD electrode displacement which initially went undetected. One presentation was a result of a coincidental chest x-ray for respiratory exacerbation and another with an untreated episode highlighted via remote monitoring, both patients were booked to clinic for further investigation. Our findings highlighted had there been a comparison of the existing subcutaneous electrogram (S-ECG) to captured S-ECGs at time of implant the electrode displacement would have been detected beforehand. This underpins the importance of introducing the simple management strategy into routine follow-up.</p>\",\"PeriodicalId\":54653,\"journal\":{\"name\":\"Pace-Pacing and Clinical Electrophysiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pace-Pacing and Clinical Electrophysiology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1111/pace.15023\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pace-Pacing and Clinical Electrophysiology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1111/pace.15023","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

我们描述了两例皮下植入式心律转复除颤器(S-ICD)植入二级预防和随后的 S-ICD 电极移位病例,这两例病例最初都未被发现。其中一名患者因呼吸道症状加重而偶然接受了胸部 X 光检查,另一名患者则是通过远程监控发现了未经治疗的病症,这两名患者都被预约到诊所接受进一步检查。我们的研究结果表明,如果将现有的皮下电图(S-ECG)与植入时捕获的 S-ECG 进行比较,就能提前发现电极移位。这说明将简单管理策略引入常规随访的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Two cases of silent subcutaneous implantable cardioverter defibrillator electrode displacement.

We describe two cases of secondary prevention subcutaneous implantable cardioverter defibrillator (S-ICD) implantation and subsequent S-ICD electrode displacement which initially went undetected. One presentation was a result of a coincidental chest x-ray for respiratory exacerbation and another with an untreated episode highlighted via remote monitoring, both patients were booked to clinic for further investigation. Our findings highlighted had there been a comparison of the existing subcutaneous electrogram (S-ECG) to captured S-ECGs at time of implant the electrode displacement would have been detected beforehand. This underpins the importance of introducing the simple management strategy into routine follow-up.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Pace-Pacing and Clinical Electrophysiology
Pace-Pacing and Clinical Electrophysiology 医学-工程:生物医学
CiteScore
2.70
自引率
5.60%
发文量
209
审稿时长
2-4 weeks
期刊介绍: Pacing and Clinical Electrophysiology (PACE) is the foremost peer-reviewed journal in the field of pacing and implantable cardioversion defibrillation, publishing over 50% of all English language articles in its field, featuring original, review, and didactic papers, and case reports related to daily practice. Articles also include editorials, book reviews, Musings on humane topics relevant to medical practice, electrophysiology (EP) rounds, device rounds, and information concerning the quality of devices used in the practice of the specialty.
期刊最新文献
Coronary Spasm Due to Pulsed Field Ablation: A State-of-the-Art Review. Recalled But Responsive: Easier Extraction of Recalled Leads. Vein of Marshall Ethanol Infusion: Beware the Left Atrial Appendage Isolation. Changes in QRS morphology during antidromic atrioventricular reentrant tachycardia. Exercise-induced type 1 Brugada pattern in a child.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1